34 The Fintek F71805F/FG Super I/O chip includes complete hardware monitoring
41 The Fintek F71872F/FG Super I/O chip is almost the same, with two
45 The Fintek F71806F/FG Super-I/O chip is essentially the same as the
53 ------------------
55 Voltages are sampled by an 8-bit ADC with a LSB of 8 mV. The supported
71 in1 VIN1 VTT1.2V 10K - 1.00 1.20 V
76 in6 VIN6 VCC1.5V 10K - 1.00 1.50 V
77 in7 VIN7 VCORE 10K - 1.00 ~1.40 V (1)
97 --------------
99 Fan rotation speeds are reported as 12-bit values from a gated clock
105 The chip assumes 2 pulse-per-revolution fans.
107 An alarm is triggered if the rotation speed drops below a programmable
112 ----------------------
127 -----------
129 Both PWM (pulse-width modulation) and DC fan speed control methods are
138 control, but may generate annoying high-pitch noise. So a frequency just
156 You define 3 temperature/fan speed trip points using the
158 relationship between temperature and fan speed with two additional points
162 * 3: Fan speed mode
163 You ask for a specific fan speed by writing to the fan<n>_target file.