7     Addresses scanned: -
11 Addresses scanned: -
15 Addresses scanned: -
19 Addresses scanned: -
24 Addresses scanned: -
28 Addresses scanned: -
32 Addresses scanned: -
36 Addresses scanned: -
40 Addresses scanned: -
44 Addresses scanned: -
48 Addresses scanned: -
52 Addresses scanned: -
56 Addresses scanned: -
59 Author: Guenter Roeck <linux@roeck-us.net>
63 -----------
68 LTC2980 is a 16-channel Power System Manager, consisting of two LTC2977
71 LTC3880, LTC3882, LTC3886, and LTC3887 are dual output poly-phase step-down
73 LTC3883 is a single phase step-down DC/DC controller.
74 LTM2987 is a 16-channel Power System Manager with two LTC2977 plus
82 -----------
91 # echo ltc2978 0x60 > /sys/bus/i2c/devices/i2c-1/new_device
95 ----------------
108 in1_max_alarm Input voltage high alarm.
114 in1_crit_alarm Input voltage critical high alarm.
121 in[N]_label "vout[1-8]".
122 LTC2974, LTC2975: N=2-5
123 LTC2977, LTC2980, LTM2987: N=2-9
124 LTC2978: N=2-9
126 N=2-3
128 in[N]_input Measured output voltage.
129 in[N]_min Minimum output voltage.
130 in[N]_max Maximum output voltage.
131 in[N]_lcrit Critical minimum output voltage.
132 in[N]_crit Critical maximum output voltage.
133 in[N]_min_alarm Output voltage low alarm.
134 in[N]_max_alarm Output voltage high alarm.
135 in[N]_lcrit_alarm Output voltage critical low alarm.
136 in[N]_crit_alarm Output voltage critical high alarm.
137 in[N]_lowest Lowest output voltage. LTC2974, LTC2975,
139 in[N]_highest Highest output voltage.
140 in[N]_reset_history Reset output voltage history.
143 On LTC2974 and LTC2975, temp[1-4] report external
157 temp[N]_crit Critical high temperature.
161 temp[N]_max_alarm Temperature high alarm.
163 temp[N]_crit_alarm Temperature critical high alarm.
177 power[N]_label "pout[1-4]".
178 LTC2974, LTC2975: N=1-4
182 N=1-2
184 power[N]_input Measured output power.
190 curr1_max_alarm Input current high alarm.
194 curr[N]_label "iout[1-4]".
195 LTC2974, LTC2975: N=1-4
199 N=2-3
201 curr[N]_input Measured output current.
202 curr[N]_max Maximum output current.
203 curr[N]_crit Critical high output current.
204 curr[N]_lcrit Critical low output current. LTC2974 and LTC2975 only.
205 curr[N]_max_alarm Output current high alarm.
206 curr[N]_crit_alarm Output current critical high alarm.
207 curr[N]_lcrit_alarm Output current critical low alarm.
209 curr[N]_lowest Lowest output current. LTC2974 and LTC2975 only.
210 curr[N]_highest Highest output current.
211 curr[N]_reset_history Reset output current history.