1Dallas DS1307 and compatible RTC 2 3Required properties: 4- compatible: should be one of: 5 "dallas,ds1307", 6 "dallas,ds1308", 7 "dallas,ds1337", 8 "dallas,ds1338", 9 "dallas,ds1339", 10 "dallas,ds1388", 11 "dallas,ds1340", 12 "dallas,ds1341", 13 "maxim,ds3231", 14 "st,m41t0", 15 "st,m41t00", 16 "st,m41t11", 17 "microchip,mcp7940x", 18 "microchip,mcp7941x", 19 "pericom,pt7c4338", 20 "epson,rx8025", 21 "isil,isl12057" 22- reg: I2C bus address of the device 23 24Optional properties: 25- interrupts: rtc alarm interrupt. 26- clock-output-names: From common clock binding to override the default output 27 clock name 28- wakeup-source: Enables wake up of host system on alarm 29- trickle-resistor-ohms : ds1339, ds1340 and ds 1388 only 30 Selected resistor for trickle charger 31 Possible values are 250, 2000, 4000 32 Should be given if trickle charger should be enabled 33- trickle-diode-disable : ds1339, ds1340 and ds 1388 only 34 Do not use internal trickle charger diode 35 Should be given if internal trickle charger diode should be disabled 36 37Example: 38 rtc1: ds1339@68 { 39 compatible = "dallas,ds1339"; 40 reg = <0x68>; 41 interrupt-parent = <&gpio4>; 42 interrupts = <20 0>; 43 trickle-resistor-ohms = <250>; 44 }; 45