README.md
1# Thermal Manager
2
3- [Introduction](#section0056945901)
4- [Directory Structure](#section0056945902)
5- [Configuration Description](#section0056945903)
6- [Repositories Involved](#section0056945904)
7
8## Introduction<a name="section0056945901"></a>
9
10The thermal manager provides the device temperature management and control capabilities to ensure the thermal safety and experience of the entire system.
11
12**Figure 1** Architecture of the thermal manager
13
14
15**Key components of the thermal manager**:
16
171. Thermal Manager: provides temperature query and callback APIs for applications and other subsystems.
182. Thermal Service: implements core temperature control functions, such as temperature detection, temperature level arbitration, and action delivery, according to the configuration file.
193. Thermal HDI: implements temperature driver information reporting and driver instruction delivery according to the configuration file.
204. Thermal Protector: implements simplified temperature control in the non-running state according to the configuration file.
21
22## Directory Structure<a name="section0056945902"></a>
23```
24/base/powermgr/thermal_manager
25├── application # Native application
26│ └── protector # Thermal Protector code
27├── etc # Init configuration
28├── figures # Architecture diagram
29├── frameworks # Architecture layer
30│ ├── dialog # Dialog
31│ ├── napi # NAPI layer
32│ └── native # Native layer
33├── interface # APIs
34│ ├── innerkits # Internal APIs
35│ └── kits # External APIs
36├── sa_profile # SA profile
37├── services # Thermal Service code
38│ ├── native # Native APIs
39│ └── zidl # Zidl APIs
40├── test # Test code
41│ ├── fuzztest # Fuzz test
42│ └── systemtest # Systemtest
43└── utils # Utilities
44```
45
46## Configuration Description<a name="section0056945903"></a>
47**1. thermal\_service\_config.xml**
48Configuration example:
49
50```
51<?xml version="1.0" encoding="UTF-8"?>
52<thermal version="0.99" product="ipx">
53 <base>
54 <item tag="temperature_query_enum" value="soc,battery,shell,ambient"/>
55 </base>
56 <level>
57 <sensor_cluster name="warm_base" sensor="shell">
58 <item level="1" threshold="35000" threshold_clr="33000"/>
59 <item level="2" threshold="37000" threshold_clr="35000"/>
60 <item level="3" threshold="40000" threshold_clr="38000"/>
61 </sensor_cluster>
62 <sensor_cluster name="warm_safe" sensor="battery,pa">
63 <item level="1" threshold="48000,60000" threshold_clr="45000,55000"/>
64 </sensor_cluster>
65 </level>
66 <state>
67 <item name="screen"/>
68 <item name="charge"/>
69 </state>
70 <action>
71 <item name="cpu"/>
72 <item name="current"/>
73 <item name="shut_down" param="100"/>
74 <item name="thermal_level" strict="1"/>
75 </action>
76 <policy>
77 <config name="warm_base" level="1">
78 <cpu screen="1">2800000</cpu>
79 <cpu screen="0">2400000</cpu>
80 <current charge="1">1500</current>
81 <thermal_level>3</thermal_level>
82 </config>
83 <config name="warm_base" level="2">
84 <cpu screen="1">2200000</cpu>
85 <cpu screen="0">1800000</cpu>
86 <current charge="1">1200</current>
87 <thermal_level>4</thermal_level>
88 </config>
89 <config name="warm_base" level="3">
90 <cpu screen="1">1600000</cpu>
91 <cpu screen="0">1200000</cpu>
92 <current charge="1">1000</current>
93 <thermal_level>5</thermal_level>
94 </config>
95 <config name="warm_safe" level="1">
96 <shut_down>1</shut_down>
97 </config>
98 </policy>
99</thermal>
100```
101```
102thermal # Root directory. Wherein, version indicates the version number, and product indicates the product name.
103├── base # base directory, used to configure basic parameters.
104│ └── item # item directory. Wherein, tag indicates the configuration tag, and value indicates the configuration value.
105├── level # Level directory, used to store the temperature level information.
106│ └── sensor_cluster # sensor_cluster directory, used to configure a cluster of sensors. Wherein, name indicates the cluster name, and sensor indicates the sensor name.
107│ └── item # item directory, used to configure the temperature level information. Wherein, level indicates the temperature level, threshold indicates the triggering temperature, and xxx_clr indicates the setback temperature.
108├── state # state directory, used to configure the state machine. Wherein, name indicates the name of the state machine.
109├── action # action directory, used to configure actions. Wherein, name indicates the name of the action, param indicates the action parameter, and strict indicates the arbitration scheme.
110└── policy # policy directory, used to configure the policy for the corresponding temperature level.
111 └── config # config directory, used to configure the action for the corresponding temperature level. Wherein, name is that of sensor_cluster, and the level is that of the item in sensor_cluster.
112 └── <action_name> # action name corresponding to the action value. The state condition and its value can be configured in this attribute.
113```
114
115
116## Repositories Involved<a name="section0056945904"></a>
117[Power Management Subsystem](https://gitee.com/openharmony/docs/blob/master/en/readme/power-management.md)
118
119[powermgr_power_manager](https://gitee.com/openharmony/powermgr_power_manager)
120
121[powermgr_display_manager](https://gitee.com/openharmony/powermgr_display_manager)
122
123[powermgr_battery_manager](https://gitee.com/openharmony/powermgr_battery_manager)
124
125**powermgr_thermal_manager**
126
127[powermgr_battery_statistics](https://gitee.com/openharmony/powermgr_battery_statistics)
128
129[powermgr_battery_lite](https://gitee.com/openharmony/powermgr_battery_lite)
130
131[powermgr_powermgr_lite](https://gitee.com/openharmony/powermgr_powermgr_lite)