Home
last modified time | relevance | path

Searched refs:INVALID_BATT_INT_VALUE (Results 1 – 8 of 8) sorted by relevance

/base/powermgr/battery_manager/services/zidl/src/
Dbattery_srv_proxy.cpp31 RETURN_IF_WITH_RET(remote == nullptr, INVALID_BATT_INT_VALUE); in GetCapacity()
38 return INVALID_BATT_INT_VALUE; in GetCapacity()
46 return INVALID_BATT_INT_VALUE; in GetCapacity()
48 int32_t capacity = INVALID_BATT_INT_VALUE; in GetCapacity()
49 READ_PARCEL_WITH_RET(reply, Int32, capacity, INVALID_BATT_INT_VALUE); in GetCapacity()
131 RETURN_IF_WITH_RET(remote == nullptr, INVALID_BATT_INT_VALUE); in GetVoltage()
138 return INVALID_BATT_INT_VALUE; in GetVoltage()
146 return INVALID_BATT_INT_VALUE; in GetVoltage()
148 int32_t voltage = INVALID_BATT_INT_VALUE; in GetVoltage()
149 READ_PARCEL_WITH_RET(reply, Int32, voltage, INVALID_BATT_INT_VALUE); in GetVoltage()
[all …]
/base/powermgr/battery_manager/services/native/include/
Dbattery_service.h114 int32_t dialogId_ { INVALID_BATT_INT_VALUE };
115 int32_t warnCapacity_ { INVALID_BATT_INT_VALUE };
118 int32_t shutdownCapacityThreshold_ = { INVALID_BATT_INT_VALUE };
119 int32_t criticalCapacityThreshold_ = { INVALID_BATT_INT_VALUE };
120 int32_t warningCapacityThreshold_ = { INVALID_BATT_INT_VALUE };
121 int32_t lowCapacityThreshold_ = { INVALID_BATT_INT_VALUE };
122 int32_t normalCapacityThreshold_ = { INVALID_BATT_INT_VALUE };
123 int32_t highCapacityThreshold_ = { INVALID_BATT_INT_VALUE };
124 int32_t fullCapacityThreshold_ = { INVALID_BATT_INT_VALUE };
/base/powermgr/battery_manager/interfaces/inner_api/native/include/
Dbattery_info.h23 static constexpr int32_t INVALID_BATT_INT_VALUE = -1; variable
439 int32_t capacity_ = INVALID_BATT_INT_VALUE;
440 int32_t voltage_ = INVALID_BATT_INT_VALUE;
442 int32_t totalEnergy_ = INVALID_BATT_INT_VALUE;
443 int32_t curAverage_ = INVALID_BATT_INT_VALUE;
444 int32_t nowCurr_ = INVALID_BATT_INT_VALUE;
445 int32_t pluggedMaxCurrent_ = INVALID_BATT_INT_VALUE;
446 int32_t pluggedMaxVoltage_ = INVALID_BATT_INT_VALUE;
447 int32_t chargeCounter_ = INVALID_BATT_INT_VALUE;
448 int32_t remainEnergy_ = INVALID_BATT_INT_VALUE;
/base/powermgr/battery_manager/test/unittest/src/
Dbattery_srv_proxy_mock_test.cpp63 EXPECT_TRUE(capacity == INVALID_BATT_INT_VALUE);
138 EXPECT_TRUE(totalEnergy == INVALID_BATT_INT_VALUE);
150 EXPECT_TRUE(currentAverage == INVALID_BATT_INT_VALUE);
162 EXPECT_TRUE(nowCurrent == INVALID_BATT_INT_VALUE);
174 EXPECT_TRUE(remainEnergy == INVALID_BATT_INT_VALUE);
223 EXPECT_TRUE(voltage == INVALID_BATT_INT_VALUE);
/base/powermgr/battery_manager/frameworks/native/src/
Dbattery_srv_client.cpp89 int32_t capacity = INVALID_BATT_INT_VALUE; in GetCapacity()
121 int32_t voltage = INVALID_BATT_INT_VALUE; in GetVoltage()
153 int32_t nowCurrent = INVALID_BATT_INT_VALUE; in GetNowCurrent()
161 int32_t remainEnergy = INVALID_BATT_INT_VALUE; in GetRemainEnergy()
169 int32_t totalEnergy = INVALID_BATT_INT_VALUE; in GetTotalEnergy()
/base/powermgr/battery_manager/services/native/src/
Dbattery_service.cpp444 int32_t voltage = INVALID_BATT_INT_VALUE; in GetVoltage()
482 int32_t temperature = INVALID_BATT_INT_VALUE; in GetBatteryTemperature()
489 int32_t totalEnergy = INVALID_BATT_INT_VALUE; in GetTotalEnergy()
510 int32_t curAverage = INVALID_BATT_INT_VALUE; in GetCurrentAverage()
517 int32_t nowCurr = INVALID_BATT_INT_VALUE; in GetNowCurrent()
534 int32_t remainEnergy = INVALID_BATT_INT_VALUE; in GetRemainEnergy()
603 return capacityThreshold != INVALID_BATT_INT_VALUE; in IsCapacityLevelDefined()
/base/powermgr/battery_manager/frameworks/napi/
Dsystem_battery.h63 int32_t capacity_ { INVALID_BATT_INT_VALUE };
Dsystem_battery.cpp204 …return (capacity_ != INVALID_BATT_INT_VALUE) && (chargingState_ != BatteryChargeState::CHARGE_STAT… in GetBatteryInfo()