Home
last modified time | relevance | path

Searched +full:cpu +full:- +full:core (Results 1 – 25 of 1080) sorted by relevance

12345678910>>...44

/kernel/linux/linux-6.6/Documentation/arch/x86/
Dtopology.rst1 .. SPDX-License-Identifier: GPL-2.0
11 The architecture-agnostic topology definitions are in
12 Documentation/admin-guide/cputopology.rst. This file holds x86-specific
17 Needless to say, code should use the generic functions - this file is *only*
35 - packages
36 - cores
37 - threads
48 Package-related topology information in the kernel:
50 - cpuinfo_x86.x86_max_cores:
54 - cpuinfo_x86.x86_max_dies:
[all …]
/kernel/linux/linux-5.10/Documentation/x86/
Dtopology.rst1 .. SPDX-License-Identifier: GPL-2.0
11 The architecture-agnostic topology definitions are in
12 Documentation/admin-guide/cputopology.rst. This file holds x86-specific
17 Needless to say, code should use the generic functions - this file is *only*
35 - packages
36 - cores
37 - threads
48 Package-related topology information in the kernel:
50 - cpuinfo_x86.x86_max_cores:
54 - cpuinfo_x86.x86_max_dies:
[all …]
/kernel/linux/linux-5.10/arch/mips/kernel/
Dsmp-cps.c1 // SPDX-License-Identifier: GPL-2.0-or-later
7 #include <linux/cpu.h>
17 #include <asm/mips-cps.h>
20 #include <asm/pm-cps.h>
22 #include <asm/smp-cps.h>
38 static unsigned core_vpe_count(unsigned int cluster, unsigned core) in core_vpe_count() argument
43 return mips_cps_numvps(cluster, core); in core_vpe_count()
69 /* Use the number of VPEs in cluster 0 core 0 for smp_num_siblings */ in cps_smp_setup()
73 for (v = 0; v < min_t(int, core_vpes, NR_CPUS - nvpes); v++) { in cps_smp_setup()
86 /* Indicate present CPUs (CPU being synonymous with VPE) */ in cps_smp_setup()
[all …]
/kernel/linux/linux-6.6/arch/mips/kernel/
Dsmp-cps.c1 // SPDX-License-Identifier: GPL-2.0-or-later
7 #include <linux/cpu.h>
18 #include <asm/mips-cps.h>
21 #include <asm/pm-cps.h>
24 #include <asm/smp-cps.h>
32 static unsigned __init core_vpe_count(unsigned int cluster, unsigned core) in core_vpe_count() argument
34 return min(smp_max_threads, mips_cps_numvps(cluster, core)); in core_vpe_count()
60 /* Use the number of VPEs in cluster 0 core 0 for smp_num_siblings */ in cps_smp_setup()
64 for (v = 0; v < min_t(int, core_vpes, NR_CPUS - nvpes); v++) { in cps_smp_setup()
77 /* Indicate present CPUs (CPU being synonymous with VPE) */ in cps_smp_setup()
[all …]
/kernel/linux/linux-6.6/tools/perf/tests/
Dtopology.c1 // SPDX-License-Identifier: GPL-2.0
14 #define TEMPL "/tmp/perf-test-XXXXXX"
26 return -1; in get_temp()
44 session->evlist = evlist__new_default(); in session_write_header()
45 TEST_ASSERT_VAL("can't get evlist", session->evlist); in session_write_header()
47 perf_header__set_feat(&session->header, HEADER_CPU_TOPOLOGY); in session_write_header()
48 perf_header__set_feat(&session->header, HEADER_NRCPUS); in session_write_header()
49 perf_header__set_feat(&session->header, HEADER_ARCH); in session_write_header()
51 session->header.data_size += DATA_SIZE; in session_write_header()
54 !perf_session__write_header(session, session->evlist, data.file.fd, true)); in session_write_header()
[all …]
/kernel/linux/linux-5.10/Documentation/admin-guide/pm/
Dintel-speed-select.rst1 .. SPDX-License-Identifier: GPL-2.0
8 collection of features that give more granular control over CPU performance.
14 - https://www.intel.com/content/www/us/en/architecture-and-technology/speed-select-technology-artic…
15 - https://builders.intel.com/docs/networkbuilders/intel-speed-select-technology-base-frequency-enha…
19 dynamically without pre-configuring via BIOS setup options. This dynamic
29 intel-speed-select configuration tool
32 Most Linux distribution packages may include the "intel-speed-select" tool. If not,
38 # cd tools/power/x86/intel-speed-select/
43 ------------
47 # intel-speed-select --help
[all …]
/kernel/linux/linux-6.6/Documentation/devicetree/bindings/cpu/
Dcpu-topology.txt2 CPU topology binding description
6 1 - Introduction
12 - socket
13 - cluster
14 - core
15 - thread
17 The bottom hierarchy level sits at core or thread level depending on whether
18 symmetric multi-threading (SMT) is supported or not.
20 For instance in a system where CPUs support SMT, "cpu" nodes represent all
22 In systems where SMT is not supported "cpu" nodes represent all cores present
[all …]
/kernel/linux/linux-5.10/Documentation/devicetree/bindings/cpu/
Dcpu-topology.txt2 CPU topology binding description
6 1 - Introduction
12 - socket
13 - cluster
14 - core
15 - thread
17 The bottom hierarchy level sits at core or thread level depending on whether
18 symmetric multi-threading (SMT) is supported or not.
20 For instance in a system where CPUs support SMT, "cpu" nodes represent all
22 In systems where SMT is not supported "cpu" nodes represent all cores present
[all …]
/kernel/linux/linux-6.6/Documentation/admin-guide/pm/
Dintel-speed-select.rst1 .. SPDX-License-Identifier: GPL-2.0
8 collection of features that give more granular control over CPU performance.
14 - https://www.intel.com/content/www/us/en/architecture-and-technology/speed-select-technology-artic…
15 - https://builders.intel.com/docs/networkbuilders/intel-speed-select-technology-base-frequency-enha…
19 dynamically without pre-configuring via BIOS setup options. This dynamic
29 intel-speed-select configuration tool
32 Most Linux distribution packages may include the "intel-speed-select" tool. If not,
38 # cd tools/power/x86/intel-speed-select/
43 ------------
47 # intel-speed-select --help
[all …]
/kernel/linux/linux-5.10/arch/powerpc/include/asm/
Dcputhreads.h1 /* SPDX-License-Identifier: GPL-2.0 */
13 * threads per core and the same number for each core in the system
15 * as the CPU numbers are still allocated, just not brought online).
35 /* cpu_thread_mask_to_cores - Return a cpumask of one per cores
40 * This function returns a cpumask which will have one online cpu's
41 * bit set for each core that has at least one thread set in the argument.
44 * since those need to be done only once per core/TLB
49 int i, cpu; in cpu_thread_mask_to_cores() local
55 cpu = cpumask_next_and(-1, &tmp, cpu_online_mask); in cpu_thread_mask_to_cores()
56 if (cpu < nr_cpu_ids) in cpu_thread_mask_to_cores()
[all …]
/kernel/linux/linux-6.6/tools/perf/util/
Dbpf_counter_cgroup.c1 // SPDX-License-Identifier: GPL-2.0
42 #define FD(evt, cpu) (*(int *)xyarray__entry(evt->core.fd, cpu, 0)) argument
50 struct perf_cpu cpu; in bperf_load_program() local
51 int total_cpus = cpu__max_cpu().cpu; in bperf_load_program()
58 return -1; in bperf_load_program()
61 skel->rodata->num_cpus = total_cpus; in bperf_load_program()
62 skel->rodata->num_events = evlist->core.nr_entries / nr_cgroups; in bperf_load_program()
64 BUG_ON(evlist->core.nr_entries % nr_cgroups != 0); in bperf_load_program()
66 /* we need one copy of events per cpu for reading */ in bperf_load_program()
67 map_size = total_cpus * evlist->core.nr_entries / nr_cgroups; in bperf_load_program()
[all …]
/kernel/linux/linux-5.10/arch/loongarch/loongson64/
Dsmp.c1 // SPDX-License-Identifier: GPL-2.0-or-later
9 #include <linux/cpu.h>
46 static u32 (*ipi_read_clear)(int cpu);
47 static void (*ipi_write_action)(int cpu, u32 action);
61 unsigned int cpu, i; in show_ipi_list() local
64 seq_printf(p, "%*s%u:%s", prec - 1, "IPI", i, prec >= 4 ? " " : ""); in show_ipi_list()
65 for_each_online_cpu(cpu) in show_ipi_list()
66 seq_printf(p, "%10u ", per_cpu(irq_stat, cpu).ipi_irqs[i]); in show_ipi_list()
72 static void csr_mail_send(uint64_t data, int cpu, int mailbox) in csr_mail_send() argument
79 val |= (cpu << IOCSR_MBUF_SEND_CPU_SHIFT); in csr_mail_send()
[all …]
/kernel/linux/linux-6.6/tools/perf/pmu-events/arch/x86/haswell/
Dhsw-metrics.json4 "MetricExpr": "cstate_pkg@c2\\-residency@ / TSC",
10 "BriefDescription": "C3 residency percent per core",
11 "MetricExpr": "cstate_core@c3\\-residency@ / TSC",
18 "MetricExpr": "cstate_pkg@c3\\-residency@ / TSC",
24 "BriefDescription": "C6 residency percent per core",
25 "MetricExpr": "cstate_core@c6\\-residency@ / TSC",
32 "MetricExpr": "cstate_pkg@c6\\-residency@ / TSC",
38 "BriefDescription": "C7 residency percent per core",
39 "MetricExpr": "cstate_core@c7\\-residency@ / TSC",
46 "MetricExpr": "cstate_pkg@c7\\-residency@ / TSC",
[all …]
/kernel/linux/linux-6.6/arch/powerpc/include/asm/
Dcputhreads.h1 /* SPDX-License-Identifier: GPL-2.0 */
13 * threads per core and the same number for each core in the system
15 * as the CPU numbers are still allocated, just not brought online).
41 int cpu_core_index_of_thread(int cpu);
42 int cpu_first_thread_of_core(int core);
44 static inline int cpu_core_index_of_thread(int cpu) { return cpu; } in cpu_core_index_of_thread() argument
45 static inline int cpu_first_thread_of_core(int core) { return core; } in cpu_first_thread_of_core() argument
48 static inline int cpu_thread_in_core(int cpu) in cpu_thread_in_core() argument
50 return cpu & (threads_per_core - 1); in cpu_thread_in_core()
53 static inline int cpu_thread_in_subcore(int cpu) in cpu_thread_in_subcore() argument
[all …]
/kernel/linux/linux-6.6/arch/arm/mach-bcm/
Dplatsmp.c1 // SPDX-License-Identifier: GPL-2.0
3 * Copyright (C) 2014-2015 Broadcom Corporation
12 #include <linux/irqchip/irq-bcm2836.h>
34 #define OF_SECONDARY_BOOT "secondary-boot-reg"
54 return -ENXIO; in scu_a9_enable()
60 pr_err("hardware reports only one core\n"); in scu_a9_enable()
61 return -ENOENT; in scu_a9_enable()
68 return -ENOMEM; in scu_a9_enable()
78 static u32 secondary_boot_addr_for(unsigned int cpu) in secondary_boot_addr_for() argument
81 struct device_node *cpu_node = of_get_cpu_node(cpu, NULL); in secondary_boot_addr_for()
[all …]
/kernel/linux/linux-5.10/arch/arm/mach-bcm/
Dplatsmp.c1 // SPDX-License-Identifier: GPL-2.0
3 * Copyright (C) 2014-2015 Broadcom Corporation
12 #include <linux/irqchip/irq-bcm2836.h>
34 #define OF_SECONDARY_BOOT "secondary-boot-reg"
54 return -ENXIO; in scu_a9_enable()
60 pr_err("hardware reports only one core\n"); in scu_a9_enable()
61 return -ENOENT; in scu_a9_enable()
68 return -ENOMEM; in scu_a9_enable()
78 static u32 secondary_boot_addr_for(unsigned int cpu) in secondary_boot_addr_for() argument
81 struct device_node *cpu_node = of_get_cpu_node(cpu, NULL); in secondary_boot_addr_for()
[all …]
/kernel/linux/linux-5.10/tools/power/cpupower/lib/
Dcpupower.c1 // SPDX-License-Identifier: GPL-2.0-only
3 * (C) 2004-2009 Dominik Brodowski <linux@dominikbrodowski.de>
23 if (fd == -1) in cpupower_read_sysfs()
26 numread = read(fd, buf, buflen - 1); in cpupower_read_sysfs()
39 * Detect whether a CPU is online
42 * 1 -> if CPU is online
43 * 0 -> if CPU is offline
46 int cpupower_is_cpu_online(unsigned int cpu) in cpupower_is_cpu_online() argument
56 snprintf(path, sizeof(path), PATH_TO_CPU "cpu%u", cpu); in cpupower_is_cpu_online()
63 * -> cpuX directory exists, but not cpuX/online file in cpupower_is_cpu_online()
[all …]
/kernel/linux/linux-6.6/tools/power/cpupower/lib/
Dcpupower.c1 // SPDX-License-Identifier: GPL-2.0-only
3 * (C) 2004-2009 Dominik Brodowski <linux@dominikbrodowski.de>
19 if (access(path, F_OK) == -1) in is_valid_path()
30 if (fd == -1) in cpupower_read_sysfs()
33 numread = read(fd, buf, buflen - 1); in cpupower_read_sysfs()
51 if (fd == -1) in cpupower_write_sysfs()
54 numwritten = write(fd, buf, buflen - 1); in cpupower_write_sysfs()
58 return -1; in cpupower_write_sysfs()
67 * Detect whether a CPU is online
70 * 1 -> if CPU is online
[all …]
/kernel/linux/linux-5.10/Documentation/devicetree/bindings/regulator/
Dnvidia,tegra-regulators-coupling.txt4 NVIDIA Tegra SoC's have a mandatory voltage-coupling between regulators.
9 ------------------------
11 On Tegra20 SoC's there are 3 coupled regulators: CORE, RTC and CPU.
12 The CORE and RTC voltages shall be in a range of 170mV from each other
13 and they both shall be higher than the CPU voltage by at least 120mV.
16 ------------------------
18 On Tegra30 SoC's there are 2 coupled regulators: CORE and CPU. The CORE
19 and CPU voltages shall be in a range of 300mV from each other and CORE
20 voltage shall be higher than the CPU by N mV, where N depends on the CPU
24 - nvidia,tegra-core-regulator: Boolean property that designates regulator
[all …]
/kernel/linux/linux-6.6/Documentation/devicetree/bindings/regulator/
Dnvidia,tegra-regulators-coupling.txt4 NVIDIA Tegra SoC's have a mandatory voltage-coupling between regulators.
9 ------------------------
11 On Tegra20 SoC's there are 3 coupled regulators: CORE, RTC and CPU.
12 The CORE and RTC voltages shall be in a range of 170mV from each other
13 and they both shall be higher than the CPU voltage by at least 120mV.
16 ------------------------
18 On Tegra30 SoC's there are 2 coupled regulators: CORE and CPU. The CORE
19 and CPU voltages shall be in a range of 300mV from each other and CORE
20 voltage shall be higher than the CPU by N mV, where N depends on the CPU
24 - nvidia,tegra-core-regulator: Boolean property that designates regulator
[all …]
/kernel/linux/linux-6.6/drivers/platform/x86/intel/ifs/
Druntest.c1 // SPDX-License-Identifier: GPL-2.0-only
4 #include <linux/cpu.h>
15 * ifs_sem. On HT systems all threads on a core will
17 * core will update results of the test.
27 * Number of TSC cycles that a logical CPU will wait for the other
28 * logical CPU on the core in the WRMSR(ACTIVATE_SCAN).
50 "Core Abort SCAN Response due to power management condition.",
53 [IFS_CORE_NOT_CAPABLE_CURRENTLY] = "Core not capable of performing SCAN currently",
56 "Exceeded number of Logical Processors (LP) allowed to run Scan-At-Field concurrently",
60 static void message_not_tested(struct device *dev, int cpu, union ifs_status status) in message_not_tested() argument
[all …]
/kernel/linux/linux-5.10/arch/loongarch/kvm/intc/
Dls3a_ipi.c1 // SPDX-License-Identifier: GPL-2.0
3 * Copyright (C) 2020-2022 Loongson Technology Corporation Limited
11 #define ls3a_gipi_lock(s, flags) spin_lock_irqsave(&s->lock, flags)
12 #define ls3a_gipi_unlock(s, flags) spin_unlock_irqrestore(&s->lock, flags)
16 int kvm_helper_send_ipi(struct kvm_vcpu *vcpu, unsigned int cpu, unsigned int action) in kvm_helper_send_ipi() argument
18 struct kvm *kvm = vcpu->kvm; in kvm_helper_send_ipi()
20 gipiState *s = &(ipi->ls3a_gipistate); in kvm_helper_send_ipi()
24 kvm->stat.pip_write_exits++; in kvm_helper_send_ipi()
27 if (s->core[cpu].status == 0) { in kvm_helper_send_ipi()
28 irq.cpu = cpu; in kvm_helper_send_ipi()
[all …]
/kernel/linux/linux-5.10/arch/c6x/boot/dts/
Dtms320c6678.dtsi1 // SPDX-License-Identifier: GPL-2.0
4 #address-cells = <1>;
5 #size-cells = <1>;
8 #address-cells = <1>;
9 #size-cells = <0>;
11 cpu@0 {
12 device_type = "cpu";
16 cpu@1 {
17 device_type = "cpu";
21 cpu@2 {
[all …]
/kernel/linux/linux-6.6/tools/perf/pmu-events/arch/x86/haswellx/
Dhsx-metrics.json4 "MetricExpr": "cstate_pkg@c2\\-residency@ / TSC",
10 "BriefDescription": "C3 residency percent per core",
11 "MetricExpr": "cstate_core@c3\\-residency@ / TSC",
18 "MetricExpr": "cstate_pkg@c3\\-residency@ / TSC",
24 "BriefDescription": "C6 residency percent per core",
25 "MetricExpr": "cstate_core@c6\\-residency@ / TSC",
32 "MetricExpr": "cstate_pkg@c6\\-residency@ / TSC",
38 "BriefDescription": "C7 residency percent per core",
39 "MetricExpr": "cstate_core@c7\\-residency@ / TSC",
46 "MetricExpr": "cstate_pkg@c7\\-residency@ / TSC",
[all …]
/kernel/uniproton/
Duniproton.gni1 # Copyright (c) 2022-2022 Huawei Technologies Co., Ltd. All rights reserved.
8 # EITHER EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO NON-INFRINGEMENT,
11 # Create: 2022-09-21
27 " --header-path $MENUCONFIG_H" + " --file-list kconfig_files.txt" +
28 " --env-list kconfig_env.txt" + " --config-out config.gni" ],
42 cmd = "grep -c '^\s*\(kernel_module\|hdf_driver\)\s*(\s*\S*\s*)\s*{\s*\$' $build_gn"
48 …cmd = "if grep -q '^\s*\(config\s*(\s*\"public\"\s*)\|module_group\s*(\s*\"\S*\"\s*)\)\s*{\s*\$' $…
59 …cmd = "if grep -q '^\s*\(module_group\|group\)\s*(\s*\"$current_dir_name\"\s*)\s*{\s*\$' $build_gn…
134 "$OSTOPDIR/core/ipc/include",
135 "$OSTOPDIR/core/kernel/include",
[all …]

12345678910>>...44