• Home
  • Line#
  • Scopes#
  • Navigate#
  • Raw
  • Download
1# Copyright 2020 The Chromium OS Authors. All rights reserved.
2# Use of this source code is governed by a BSD-style license that can be
3# found in the LICENSE file.
4
5from autotest_lib.client.common_lib import utils
6from autotest_lib.server.hosts import cros_host
7
8AUTHOR = 'ncrews'
9DEPENDENCIES = "servo_state:WORKING"
10NAME = 'policy_DeviceChargingServer.AdvancedBatteryChargeMode'
11TIME = 'LONG'
12TEST_CATEGORY = 'General'
13TEST_CLASS = 'enterprise'
14TEST_TYPE = 'server'
15ATTRIBUTES = "suite:wilco_bve"
16
17DOC = """
18Ensures the DUT's battery level is in a testable range, clears the TPM if
19needed, and then runs the specified client test to verify charging behavior
20is consistent with policies.
21"""
22
23args_dict = utils.args_to_dict(args)
24servo_args = cros_host.CrosHost.get_servo_arguments(args_dict)
25
26client_test = 'policy_DeviceScheduledCharging'
27
28# When AdvancedBatteryChargeMode is enabled, and the time is outside of the work
29# period, the battery should not charge above 90%. Therefore we need to be above
30# 90% so we can test this.
31MIN_BATTERY_LEVEL = 91
32
33# Various interesting day_config values of the policy, assuming the time
34# is noon on a Monday.
35BEFORE_START_DAY_CONFIG = {
36    'entries': [{'day': 'MONDAY',
37                 'charge_start_time':{'hour':22, 'minute':0},
38                 'charge_end_time':{'hour':23, 'minute':0},
39                }]
40}
41START_THRU_END_DAY_CONFIG = {
42    'entries': [{'day': 'MONDAY',
43                 'charge_start_time':{'hour':1, 'minute':0},
44                 'charge_end_time':{'hour':23, 'minute':0},
45                }]
46}
47AFTER_END_DAY_CONFIG = {
48    'entries': [{'day': 'MONDAY',
49                 'charge_start_time':{'hour':1, 'minute':0},
50                 'charge_end_time':{'hour':2, 'minute':0},
51                }]
52}
53
54# A test case consists of the policies, plus the expected power behavior.
55TEST_CASES = [
56    ({'DeviceAdvancedBatteryChargeModeEnabled': False,
57      'DeviceAdvancedBatteryChargeModeDayConfig': BEFORE_START_DAY_CONFIG},
58     'ON_AC_AND_CHARGING'),
59    ({'DeviceAdvancedBatteryChargeModeEnabled': False,
60      'DeviceAdvancedBatteryChargeModeDayConfig': START_THRU_END_DAY_CONFIG},
61     'ON_AC_AND_CHARGING'),
62    ({'DeviceAdvancedBatteryChargeModeEnabled': False,
63      'DeviceAdvancedBatteryChargeModeDayConfig': AFTER_END_DAY_CONFIG},
64     'ON_AC_AND_CHARGING'),
65
66    ({'DeviceAdvancedBatteryChargeModeEnabled': True,
67      'DeviceAdvancedBatteryChargeModeDayConfig': BEFORE_START_DAY_CONFIG},
68     'ON_AC_AND_NOT_CHARGING'),
69    ({'DeviceAdvancedBatteryChargeModeEnabled': True,
70      'DeviceAdvancedBatteryChargeModeDayConfig': START_THRU_END_DAY_CONFIG},
71     'ON_AC_AND_CHARGING'),
72    ({'DeviceAdvancedBatteryChargeModeEnabled': True,
73      'DeviceAdvancedBatteryChargeModeDayConfig': AFTER_END_DAY_CONFIG},
74     'ON_AC_AND_NOT_CHARGING'),
75]
76
77# These are used to cleanup the DUT and to prep the DUT before each test case.
78# See the test for more info.
79ON_AC_AND_CHARGING_POLICIES = {
80    'DeviceAdvancedBatteryChargeModeEnabled': False,
81    'DeviceAdvancedBatteryChargeModeDayConfig': BEFORE_START_DAY_CONFIG
82}
83ON_AC_AND_NOT_CHARGING_POLICIES = {
84    'DeviceAdvancedBatteryChargeModeEnabled': True,
85    'DeviceAdvancedBatteryChargeModeDayConfig': BEFORE_START_DAY_CONFIG
86}
87PREP_POLICIES = {
88    'ON_AC_AND_CHARGING'         : (ON_AC_AND_NOT_CHARGING_POLICIES,
89                                    'ON_AC_AND_NOT_CHARGING'),
90    'ON_AC_AND_NOT_CHARGING'     : (ON_AC_AND_CHARGING_POLICIES,
91                                    'ON_AC_AND_CHARGING'),
92    'NOT_ON_AC_AND_NOT_CHARGING' : (ON_AC_AND_CHARGING_POLICIES,
93                                    'ON_AC_AND_CHARGING'),
94}
95
96
97def run(machine):
98    host = hosts.create_host(machine, servo_args=servo_args)
99    job.run_test('policy_DeviceChargingServer',
100                 host=host,
101                 client_test=client_test,
102                 test_cases=TEST_CASES,
103                 min_battery_level=MIN_BATTERY_LEVEL,
104                 prep_policies=PREP_POLICIES)
105
106parallel_simple(run, machines)
107