1#
2# Generic thermal sysfs drivers configuration
3#
4
5menuconfig THERMAL
6	tristate "Generic Thermal sysfs driver"
7	help
8	  Generic Thermal Sysfs driver offers a generic mechanism for
9	  thermal management. Usually it's made up of one or more thermal
10	  zone and cooling device.
11	  Each thermal zone contains its own temperature, trip points,
12	  cooling devices.
13	  All platforms with ACPI thermal support can use this driver.
14	  If you want this support, you should say Y or M here.
15
16if THERMAL
17
18config THERMAL_HWMON
19	bool
20	prompt "Expose thermal sensors as hwmon device"
21	depends on HWMON=y || HWMON=THERMAL
22	default y
23	help
24	  In case a sensor is registered with the thermal
25	  framework, this option will also register it
26	  as a hwmon. The sensor will then have the common
27	  hwmon sysfs interface.
28
29	  Say 'Y' here if you want all thermal sensors to
30	  have hwmon sysfs interface too.
31
32config THERMAL_OF
33	bool
34	prompt "APIs to parse thermal data out of device tree"
35	depends on OF
36	default y
37	help
38	  This options provides helpers to add the support to
39	  read and parse thermal data definitions out of the
40	  device tree blob.
41
42	  Say 'Y' here if you need to build thermal infrastructure
43	  based on device tree.
44
45config THERMAL_WRITABLE_TRIPS
46	bool "Enable writable trip points"
47	help
48	  This option allows the system integrator to choose whether
49	  trip temperatures can be changed from userspace. The
50	  writable trips need to be specified when setting up the
51	  thermal zone but the choice here takes precedence.
52
53	  Say 'Y' here if you would like to allow userspace tools to
54	  change trip temperatures.
55
56choice
57	prompt "Default Thermal governor"
58	default THERMAL_DEFAULT_GOV_STEP_WISE
59	help
60	  This option sets which thermal governor shall be loaded at
61	  startup. If in doubt, select 'step_wise'.
62
63config THERMAL_DEFAULT_GOV_STEP_WISE
64	bool "step_wise"
65	select THERMAL_GOV_STEP_WISE
66	help
67	  Use the step_wise governor as default. This throttles the
68	  devices one step at a time.
69
70config THERMAL_DEFAULT_GOV_FAIR_SHARE
71	bool "fair_share"
72	select THERMAL_GOV_FAIR_SHARE
73	help
74	  Use the fair_share governor as default. This throttles the
75	  devices based on their 'contribution' to a zone. The
76	  contribution should be provided through platform data.
77
78config THERMAL_DEFAULT_GOV_USER_SPACE
79	bool "user_space"
80	select THERMAL_GOV_USER_SPACE
81	help
82	  Select this if you want to let the user space manage the
83	  platform thermals.
84
85config THERMAL_DEFAULT_GOV_POWER_ALLOCATOR
86	bool "power_allocator"
87	select THERMAL_GOV_POWER_ALLOCATOR
88	help
89	  Select this if you want to control temperature based on
90	  system and device power allocation. This governor can only
91	  operate on cooling devices that implement the power API.
92
93endchoice
94
95config THERMAL_GOV_FAIR_SHARE
96	bool "Fair-share thermal governor"
97	help
98	  Enable this to manage platform thermals using fair-share governor.
99
100config THERMAL_GOV_STEP_WISE
101	bool "Step_wise thermal governor"
102	help
103	  Enable this to manage platform thermals using a simple linear
104	  governor.
105
106config THERMAL_GOV_BANG_BANG
107	bool "Bang Bang thermal governor"
108	default n
109	help
110	  Enable this to manage platform thermals using bang bang governor.
111
112	  Say 'Y' here if you want to use two point temperature regulation
113	  used for fans without throttling.  Some fan drivers depend on this
114	  governor to be enabled (e.g. acerhdf).
115
116config THERMAL_GOV_USER_SPACE
117	bool "User_space thermal governor"
118	help
119	  Enable this to let the user space manage the platform thermals.
120
121config THERMAL_GOV_POWER_ALLOCATOR
122	bool "Power allocator thermal governor"
123	help
124	  Enable this to manage platform thermals by dynamically
125	  allocating and limiting power to devices.
126
127config CPU_THERMAL
128	bool "generic cpu cooling support"
129	depends on CPU_FREQ
130	depends on THERMAL_OF
131	help
132	  This implements the generic cpu cooling mechanism through frequency
133	  reduction. An ACPI version of this already exists
134	  (drivers/acpi/processor_thermal.c).
135	  This will be useful for platforms using the generic thermal interface
136	  and not the ACPI interface.
137
138	  If you want this support, you should say Y here.
139
140config CLOCK_THERMAL
141	bool "Generic clock cooling support"
142	depends on COMMON_CLK
143	depends on PM_OPP
144	help
145	  This entry implements the generic clock cooling mechanism through
146	  frequency clipping. Typically used to cool off co-processors. The
147	  device that is configured to use this cooling mechanism will be
148	  controlled to reduce clock frequency whenever temperature is high.
149
150config DEVFREQ_THERMAL
151	bool "Generic device cooling support"
152	depends on PM_DEVFREQ
153	depends on PM_OPP
154	help
155	  This implements the generic devfreq cooling mechanism through
156	  frequency reduction for devices using devfreq.
157
158	  This will throttle the device by limiting the maximum allowed DVFS
159	  frequency corresponding to the cooling level.
160
161	  In order to use the power extensions of the cooling device,
162	  devfreq should use the simple_ondemand governor.
163
164	  If you want this support, you should say Y here.
165
166config THERMAL_EMULATION
167	bool "Thermal emulation mode support"
168	help
169	  Enable this option to make a emul_temp sysfs node in thermal zone
170	  directory to support temperature emulation. With emulation sysfs node,
171	  user can manually input temperature and test the different trip
172	  threshold behaviour for simulation purpose.
173
174	  WARNING: Be careful while enabling this option on production systems,
175	  because userland can easily disable the thermal policy by simply
176	  flooding this sysfs node with low temperature values.
177
178config HISI_THERMAL
179	tristate "Hisilicon thermal driver"
180	depends on (ARCH_HISI && CPU_THERMAL && OF) || COMPILE_TEST
181	depends on HAS_IOMEM
182	help
183	  Enable this to plug hisilicon's thermal sensor driver into the Linux
184	  thermal framework. cpufreq is used as the cooling device to throttle
185	  CPUs when the passive trip is crossed.
186
187config IMX_THERMAL
188	tristate "Temperature sensor driver for Freescale i.MX SoCs"
189	depends on (ARCH_MXC && CPU_THERMAL) || COMPILE_TEST
190	depends on MFD_SYSCON
191	depends on OF
192	help
193	  Support for Temperature Monitor (TEMPMON) found on Freescale i.MX SoCs.
194	  It supports one critical trip point and one passive trip point.  The
195	  cpufreq is used as the cooling device to throttle CPUs when the
196	  passive trip is crossed.
197
198config MAX77620_THERMAL
199	tristate "Temperature sensor driver for Maxim MAX77620 PMIC"
200	depends on MFD_MAX77620
201	depends on OF
202	help
203	  Support for die junction temperature warning alarm for Maxim
204	  Semiconductor PMIC MAX77620 device. Device generates two alarm
205	  interrupts when PMIC die temperature cross the threshold of
206	  120 degC and 140 degC.
207
208config QORIQ_THERMAL
209	tristate "QorIQ Thermal Monitoring Unit"
210	depends on THERMAL_OF
211	depends on HAS_IOMEM
212	help
213	  Support for Thermal Monitoring Unit (TMU) found on QorIQ platforms.
214	  It supports one critical trip point and one passive trip point. The
215	  cpufreq is used as the cooling device to throttle CPUs when the
216	  passive trip is crossed.
217
218config SPEAR_THERMAL
219	tristate "SPEAr thermal sensor driver"
220	depends on PLAT_SPEAR || COMPILE_TEST
221	depends on HAS_IOMEM
222	depends on OF
223	help
224	  Enable this to plug the SPEAr thermal sensor driver into the Linux
225	  thermal framework.
226
227config ROCKCHIP_THERMAL
228	tristate "Rockchip thermal driver"
229	depends on ARCH_ROCKCHIP || COMPILE_TEST
230	depends on RESET_CONTROLLER
231	depends on HAS_IOMEM
232	help
233	  Rockchip thermal driver provides support for Temperature sensor
234	  ADC (TS-ADC) found on Rockchip SoCs. It supports one critical
235	  trip point. Cpufreq is used as the cooling device and will throttle
236	  CPUs when the Temperature crosses the passive trip point.
237
238config RCAR_THERMAL
239	tristate "Renesas R-Car thermal driver"
240	depends on ARCH_RENESAS || COMPILE_TEST
241	depends on HAS_IOMEM
242	help
243	  Enable this to plug the R-Car thermal sensor driver into the Linux
244	  thermal framework.
245
246config KIRKWOOD_THERMAL
247	tristate "Temperature sensor on Marvell Kirkwood SoCs"
248	depends on MACH_KIRKWOOD || COMPILE_TEST
249	depends on HAS_IOMEM
250	depends on OF
251	help
252	  Support for the Kirkwood thermal sensor driver into the Linux thermal
253	  framework. Only kirkwood 88F6282 and 88F6283 have this sensor.
254
255config DOVE_THERMAL
256	tristate "Temperature sensor on Marvell Dove SoCs"
257	depends on ARCH_DOVE || MACH_DOVE || COMPILE_TEST
258	depends on HAS_IOMEM
259	depends on OF
260	help
261	  Support for the Dove thermal sensor driver in the Linux thermal
262	  framework.
263
264config DB8500_THERMAL
265	tristate "DB8500 thermal management"
266	depends on MFD_DB8500_PRCMU
267	default y
268	help
269	  Adds DB8500 thermal management implementation according to the thermal
270	  management framework. A thermal zone with several trip points will be
271	  created. Cooling devices can be bound to the trip points to cool this
272	  thermal zone if trip points reached.
273
274config ARMADA_THERMAL
275	tristate "Armada 370/XP thermal management"
276	depends on ARCH_MVEBU || COMPILE_TEST
277	depends on HAS_IOMEM
278	depends on OF
279	help
280	  Enable this option if you want to have support for thermal management
281	  controller present in Armada 370 and Armada XP SoC.
282
283config DB8500_CPUFREQ_COOLING
284	tristate "DB8500 cpufreq cooling"
285	depends on ARCH_U8500 || COMPILE_TEST
286	depends on HAS_IOMEM
287	depends on CPU_THERMAL
288	default y
289	help
290	  Adds DB8500 cpufreq cooling devices, and these cooling devices can be
291	  bound to thermal zone trip points. When a trip point reached, the
292	  bound cpufreq cooling device turns active to set CPU frequency low to
293	  cool down the CPU.
294
295config INTEL_POWERCLAMP
296	tristate "Intel PowerClamp idle injection driver"
297	depends on THERMAL
298	depends on X86
299	depends on CPU_SUP_INTEL
300	help
301	  Enable this to enable Intel PowerClamp idle injection driver. This
302	  enforce idle time which results in more package C-state residency. The
303	  user interface is exposed via generic thermal framework.
304
305config X86_PKG_TEMP_THERMAL
306	tristate "X86 package temperature thermal driver"
307	depends on X86_THERMAL_VECTOR
308	select THERMAL_GOV_USER_SPACE
309	select THERMAL_WRITABLE_TRIPS
310	default m
311	help
312	  Enable this to register CPU digital sensor for package temperature as
313	  thermal zone. Each package will have its own thermal zone. There are
314	  two trip points which can be set by user to get notifications via thermal
315	  notification methods.
316
317config INTEL_SOC_DTS_IOSF_CORE
318	tristate
319	depends on X86 && PCI
320	select IOSF_MBI
321	help
322	  This is becoming a common feature for Intel SoCs to expose the additional
323	  digital temperature sensors (DTSs) using side band interface (IOSF). This
324	  implements the common set of helper functions to register, get temperature
325	  and get/set thresholds on DTSs.
326
327config INTEL_SOC_DTS_THERMAL
328	tristate "Intel SoCs DTS thermal driver"
329	depends on X86 && PCI
330	select INTEL_SOC_DTS_IOSF_CORE
331	select THERMAL_WRITABLE_TRIPS
332	help
333	  Enable this to register Intel SoCs (e.g. Bay Trail) platform digital
334	  temperature sensor (DTS). These SoCs have two additional DTSs in
335	  addition to DTSs on CPU cores. Each DTS will be registered as a
336	  thermal zone. There are two trip points. One of the trip point can
337	  be set by user mode programs to get notifications via Linux thermal
338	  notification methods.The other trip is a critical trip point, which
339	  was set by the driver based on the TJ MAX temperature.
340
341config INTEL_QUARK_DTS_THERMAL
342	tristate "Intel Quark DTS thermal driver"
343	depends on X86_INTEL_QUARK
344	help
345	  Enable this to register Intel Quark SoC (e.g. X1000) platform digital
346	  temperature sensor (DTS). For X1000 SoC, it has one on-die DTS.
347	  The DTS will be registered as a thermal zone. There are two trip points:
348	  hot & critical. The critical trip point default value is set by
349	  underlying BIOS/Firmware.
350
351menu "ACPI INT340X thermal drivers"
352source drivers/thermal/int340x_thermal/Kconfig
353endmenu
354
355config INTEL_BXT_PMIC_THERMAL
356	tristate "Intel Broxton PMIC thermal driver"
357	depends on X86 && INTEL_SOC_PMIC && REGMAP
358	help
359	  Select this driver for Intel Broxton PMIC with ADC channels monitoring
360	  system temperature measurements and alerts.
361	  This driver is used for monitoring the ADC channels of PMIC and handles
362	  the alert trip point interrupts and notifies the thermal framework with
363	  the trip point and temperature details of the zone.
364
365config INTEL_PCH_THERMAL
366	tristate "Intel PCH Thermal Reporting Driver"
367	depends on X86 && PCI
368	help
369	  Enable this to support thermal reporting on certain intel PCHs.
370	  Thermal reporting device will provide temperature reading,
371	  programmable trip points and other information.
372
373config MTK_THERMAL
374	tristate "Temperature sensor driver for mediatek SoCs"
375	depends on ARCH_MEDIATEK || COMPILE_TEST
376	depends on HAS_IOMEM
377	depends on NVMEM || NVMEM=n
378	depends on RESET_CONTROLLER
379	default y
380	help
381	  Enable this option if you want to have support for thermal management
382	  controller present in Mediatek SoCs
383
384menu "Texas Instruments thermal drivers"
385depends on ARCH_HAS_BANDGAP || COMPILE_TEST
386depends on HAS_IOMEM
387source "drivers/thermal/ti-soc-thermal/Kconfig"
388endmenu
389
390menu "Samsung thermal drivers"
391depends on ARCH_EXYNOS || COMPILE_TEST
392source "drivers/thermal/samsung/Kconfig"
393endmenu
394
395menu "STMicroelectronics thermal drivers"
396depends on ARCH_STI && OF
397source "drivers/thermal/st/Kconfig"
398endmenu
399
400config TANGO_THERMAL
401	tristate "Tango thermal management"
402	depends on ARCH_TANGO || COMPILE_TEST
403	help
404	  Enable the Tango thermal driver, which supports the primitive
405	  temperature sensor embedded in Tango chips since the SMP8758.
406	  This sensor only generates a 1-bit signal to indicate whether
407	  the die temperature exceeds a programmable threshold.
408
409source "drivers/thermal/tegra/Kconfig"
410
411config QCOM_SPMI_TEMP_ALARM
412	tristate "Qualcomm SPMI PMIC Temperature Alarm"
413	depends on OF && SPMI && IIO
414	select REGMAP_SPMI
415	help
416	  This enables a thermal sysfs driver for Qualcomm plug-and-play (QPNP)
417	  PMIC devices. It shows up in sysfs as a thermal sensor with multiple
418	  trip points. The temperature reported by the thermal sensor reflects the
419	  real time die temperature if an ADC is present or an estimate of the
420	  temperature based upon the over temperature stage value.
421
422config GENERIC_ADC_THERMAL
423	tristate "Generic ADC based thermal sensor"
424	depends on IIO
425	help
426	  This enabled a thermal sysfs driver for the temperature sensor
427	  which is connected to the General Purpose ADC. The ADC channel
428	  is read via IIO framework and the channel information is provided
429	  to this driver. This driver reports the temperature by reading ADC
430	  channel and converts it to temperature based on lookup table.
431
432menu "Qualcomm thermal drivers"