• Home
  • Line#
  • Scopes#
  • Navigate#
  • Raw
  • Download
1 /* SPDX-License-Identifier: GPL-2.0-or-later */
2 /*
3  * tmon.h contains data structures and constants used by TMON
4  *
5  * Copyright (C) 2012 Intel Corporation. All rights reserved.
6  *
7  * Author Name Jacob Pan <jacob.jun.pan@linux.intel.com>
8  */
9 
10 #ifndef TMON_H
11 #define TMON_H
12 
13 #define MAX_DISP_TEMP 125
14 #define MAX_CTRL_TEMP 105
15 #define MIN_CTRL_TEMP 40
16 #define MAX_NR_TZONE 16
17 #define MAX_NR_CDEV 32
18 #define MAX_NR_TRIP 16
19 #define MAX_NR_CDEV_TRIP 12 /* number of cooling devices that can bind
20 			     * to a thermal zone trip.
21 			     */
22 #define MAX_TEMP_KC 140000
23 /* starting char position to draw sensor data, such as tz names
24  * trip point list, etc.
25  */
26 #define DATA_LEFT_ALIGN 10
27 #define NR_LINES_TZDATA 1
28 #define TMON_LOG_FILE "/var/tmp/tmon.log"
29 
30 extern unsigned long ticktime;
31 extern double time_elapsed;
32 extern unsigned long target_temp_user;
33 extern int dialogue_on;
34 extern char ctrl_cdev[];
35 extern pthread_mutex_t input_lock;
36 extern int tmon_exit;
37 extern int target_thermal_zone;
38 /* use fixed size record to simplify data processing and transfer
39  * TBD: more info to be added, e.g. programmable trip point data.
40 */
41 struct thermal_data_record {
42 	struct timeval tv;
43 	unsigned long temp[MAX_NR_TZONE];
44 	double pid_out_pct;
45 };
46 
47 struct cdev_info {
48 	char type[64];
49 	int instance;
50 	unsigned long max_state;
51 	unsigned long cur_state;
52 	unsigned long flag;
53 };
54 
55 enum trip_type {
56 	THERMAL_TRIP_CRITICAL,
57 	THERMAL_TRIP_HOT,
58 	THERMAL_TRIP_PASSIVE,
59 	THERMAL_TRIP_ACTIVE,
60 	NR_THERMAL_TRIP_TYPE,
61 };
62 
63 struct trip_point {
64 	enum trip_type type;
65 	unsigned long temp;
66 	unsigned long hysteresis;
67 	int attribute; /* programmability etc. */
68 };
69 
70 /* thermal zone configuration information, binding with cooling devices could
71  * change at runtime.
72  */
73 struct tz_info {
74 	char type[256]; /* e.g. acpitz */
75 	int instance;
76 	int passive; /* active zone has passive node to force passive mode */
77 	int nr_cdev; /* number of cooling device binded */
78 	int nr_trip_pts;
79 	struct trip_point tp[MAX_NR_TRIP];
80 	unsigned long cdev_binding; /* bitmap for attached cdevs */
81 	/* cdev bind trip points, allow one cdev bind to multiple trips */
82 	unsigned long trip_binding[MAX_NR_CDEV];
83 };
84 
85 struct tmon_platform_data {
86 	int nr_tz_sensor;
87 	int nr_cooling_dev;
88 	/* keep track of instance ids since there might be gaps */
89 	int max_tz_instance;
90 	int max_cdev_instance;
91 	struct tz_info *tzi;
92 	struct cdev_info *cdi;
93 };
94 
95 struct control_ops {
96 	void (*set_ratio)(unsigned long ratio);
97 	unsigned long (*get_ratio)(unsigned long ratio);
98 
99 };
100 
101 enum cdev_types {
102 	CDEV_TYPE_PROC,
103 	CDEV_TYPE_FAN,
104 	CDEV_TYPE_MEM,
105 	CDEV_TYPE_NR,
106 };
107 
108 /* REVISIT: the idea is to group sensors if possible, e.g. on intel mid
109  * we have "skin0", "skin1", "sys", "msicdie"
110  * on DPTF enabled systems, we might have PCH, TSKN, TAMB, etc.
111  */
112 enum tzone_types {
113 	TZONE_TYPE_ACPI,
114 	TZONE_TYPE_PCH,
115 	TZONE_TYPE_NR,
116 };
117 
118 /* limit the output of PID controller adjustment */
119 #define LIMIT_HIGH (95)
120 #define LIMIT_LOW  (2)
121 
122 struct pid_params {
123 	double kp;  /* Controller gain from Dialog Box */
124 	double ki;  /* Time-constant for I action from Dialog Box */
125 	double kd;  /* Time-constant for D action from Dialog Box */
126 	double ts;
127 	double k_lpf;
128 
129 	double t_target;
130 	double y_k;
131 };
132 
133 extern int init_thermal_controller(void);
134 extern void controller_handler(const double xk, double *yk);
135 
136 extern struct tmon_platform_data ptdata;
137 extern struct pid_params p_param;
138 
139 extern FILE *tmon_log;
140 extern int cur_thermal_record; /* index to the trec array */
141 extern struct thermal_data_record trec[];
142 extern const char *trip_type_name[];
143 extern unsigned long no_control;
144 
145 extern void initialize_curses(void);
146 extern void show_controller_stats(char *line);
147 extern void show_title_bar(void);
148 extern void setup_windows(void);
149 extern void disable_tui(void);
150 extern void show_sensors_w(void);
151 extern void show_data_w(void);
152 extern void write_status_bar(int x, char *line);
153 extern void show_control_w();
154 
155 extern void show_cooling_device(void);
156 extern void show_dialogue(void);
157 extern int update_thermal_data(void);
158 
159 extern int probe_thermal_sysfs(void);
160 extern void free_thermal_data(void);
161 extern	void resize_handler(int sig);
162 extern void set_ctrl_state(unsigned long state);
163 extern void get_ctrl_state(unsigned long *state);
164 extern void *handle_tui_events(void *arg);
165 extern int sysfs_set_ulong(char *path, char *filename, unsigned long val);
166 extern int zone_instance_to_index(int zone_inst);
167 extern void close_windows(void);
168 
169 #define PT_COLOR_DEFAULT    1
170 #define PT_COLOR_HEADER_BAR 2
171 #define PT_COLOR_ERROR      3
172 #define PT_COLOR_RED        4
173 #define PT_COLOR_YELLOW     5
174 #define PT_COLOR_GREEN      6
175 #define PT_COLOR_BRIGHT     7
176 #define PT_COLOR_BLUE	    8
177 
178 /* each thermal zone uses 12 chars, 8 for name, 2 for instance, 2 space
179  * also used to list trip points in forms of AAAC, which represents
180  * A: Active
181  * C: Critical
182  */
183 #define TZONE_RECORD_SIZE 12
184 #define TZ_LEFT_ALIGN 32
185 #define CDEV_NAME_SIZE 20
186 #define CDEV_FLAG_IN_CONTROL (1 << 0)
187 
188 /* dialogue box starts */
189 #define DIAG_X 48
190 #define DIAG_Y 8
191 #define THERMAL_SYSFS "/sys/class/thermal"
192 #define CDEV "cooling_device"
193 #define TZONE "thermal_zone"
194 #define TDATA_LEFT 16
195 #endif /* TMON_H */
196