| /Documentation/virt/kvm/devices/ |
| D | s390_flic.txt | 16 - register and modify adapter interrupt sources (KVM_DEV_FLIC_ADAPTER_*) 17 - modify AIS (adapter-interruption-suppression) mode state (KVM_DEV_FLIC_AISM) 18 - inject adapter interrupts on a specified adapter (KVM_DEV_FLIC_AIRQ_INJECT) 62 Register an I/O adapter interrupt source. Takes a kvm_s390_io_adapter 63 describing the adapter to register: 73 id contains the unique id for the adapter, isc the I/O interruption subclass 74 to use, maskable whether this adapter may be masked (interrupts turned off), 76 further characteristics of the adapter. 78 - KVM_S390_ADAPTER_SUPPRESSIBLE: adapter is subject to AIS 79 (adapter-interrupt-suppression) facility. This flag only has an effect if [all …]
|
| /Documentation/networking/device_drivers/cirrus/ |
| D | cs89x0.txt | 29 2.0 ADAPTER INSTALLATION and CONFIGURATION 30 2.1 CS8900-based Adapter Configuration 31 2.2 CS8920-based Adapter Configuration 42 5.2 Testing the Adapter 45 5.3 Using the Adapter's LEDs 69 CS8920-based adapters are similar to the CS8900-based adapter with additional 72 adapters. Refer to the "Adapter Configuration" section for details on 78 The CS8900/CS8920 Ethernet Adapter driver for Linux supports the Linux 103 * Cirrus Logic LAN (CS8900/20-based) Ethernet ISA Adapter 142 2.0 ADAPTER INSTALLATION and CONFIGURATION [all …]
|
| /Documentation/i2c/ |
| D | functionality.rst | 8 Because not every I2C or SMBus adapter implements everything in the 10 is implemented when it is given the option to attach to an adapter: 11 the client needs some way to check whether an adapter has the needed 57 emulated by a real I2C adapter (using 65 ADAPTER IMPLEMENTATION 68 When you write a new adapter driver, you will have to implement a 72 A typical SMBus-only adapter would list all the SMBus transactions it 75 static u32 piix4_func(struct i2c_adapter *adapter) 82 A typical full-I2C adapter would use the following (from the i2c-pxa 92 I2C_FUNC_I2C without any help from the adapter driver. The idea is [all …]
|
| D | i2c-topology.rst | 6 than a straight-forward i2c bus with one adapter and one or more devices. 20 These constructs are represented as i2c adapter trees by Linux, where 21 each adapter has a parent adapter (except the root adapter) and zero or 22 more child adapters. The root adapter is the actual adapter that issues 48 same i2c root adapter that they mux. 57 by the same i2c root adapter that they mux. 83 Mux-locked muxes does not lock the entire parent adapter during the 85 adapter are locked. Mux-locked muxes are mostly interesting if the 87 their tasks. Since the parent adapter is not fully locked during the 95 parent-locked mux that the root adapter is locked during the [all …]
|
| D | fault-codes.rst | 38 Also, codes returned by adapter probe methods follow rules which are 63 SMBus adapter) needs some fault recovery (such as resetting), 98 Returned by an adapter when asked to perform an operation 101 For example, this would be returned when an adapter that 107 Similarly, if an I2C adapter can't execute all legal I2C 110 the adapter's functionality mask, since the assumption is 111 that if an adapter supports I2C it supports all of I2C.) 120 Returned when a transfer was requested using an adapter
|
| D | dev-interface.rst | 6 possible to access all devices on an adapter from userspace, through 9 Each registered i2c adapter gets a number, counting from 0. You can 10 examine /sys/class/i2c-dev/ to see what number corresponds to which adapter. 24 So let's say you want to access an i2c adapter from a C program. 30 Now, you have to decide which adapter you want to access. You should 32 Adapter numbers are assigned somewhat dynamically, so you can not 115 if the adapter has I2C_FUNC_10BIT_ADDR. 121 the adapter has I2C_FUNC_SMBUS_PEC; it is still safe if not, it just 125 Gets the adapter functionality and puts it in ``*funcs``. 129 Only valid if the adapter has I2C_FUNC_I2C. The argument is [all …]
|
| D | summary.rst | 31 Adapter 36 of I2C adapters. Each specific adapter driver either depends on one algorithm 42 integrated than Algorithm and Adapter.
|
| /Documentation/scsi/ |
| D | BusLogic.txt | 61 the BT-948 PCI Ultra SCSI Host Adapter, and then again for the BT-958 PCI Wide 62 Ultra SCSI Host Adapter in January 1996. This was mutually beneficial since 94 adapter hardware configuration, including the synchronous transfer parameters 106 adapter will attempt to negotiate for 20.0 mega-transfers/second. 111 adapter will attempt to negotiate for 10.0 mega-transfers/second. 116 adapter will attempt to negotiate for 5.0 mega-transfers/second. 128 adapter's SCSI ID is represented by the "#". 140 addition, BusLogic's Strict Round Robin Mode is used to optimize host adapter 146 is determined automatically based on the host adapter's total queue depth and 148 addition, tagged queuing is automatically disabled whenever the host adapter [all …]
|
| /Documentation/devicetree/bindings/power/supply/ |
| D | ti,bq24735.txt | 9 adapter is either plugged in or removed. 10 - ti,ac-detect-gpios : This GPIO is optionally used to read the AC adapter 13 the GPIO must be active on AC adapter absence despite ACOK being active 14 (high) on AC adapter presence. 30 - poll-interval : In case 'interrupts' is not specified, poll AC adapter
|
| /Documentation/networking/device_drivers/neterion/ |
| D | s2io.txt | 6 - 2. Identifying the adapter/interface 20 2. Identifying the adapter/interface: 21 a. Insert the adapter(s) in your system. 27 eth3: Neterion Xframe I 10GbE adapter (rev 3), Version 2.0.9.1, Intr type INTA 28 eth4: Neterion Xframe II 10GbE adapter (rev 2), Version 2.0.9.1, Intr type INTA 31 The above messages identify the adapter type(Xframe I/II), adapter revision, 36 To associate an interface with a physical adapter use "ethtool -p <ethX>". 37 The corresponding adapter's LED will blink multiple times.
|
| /Documentation/networking/ |
| D | skfp.txt | 14 (5) INCLUSION OF THE ADAPTER IN SYSTEM START 16 (7) FUNCTION OF THE ADAPTER LEDS 27 network adapter. 36 Chapter 5: Shows the changed functionality of the adapter LEDs. 71 Therefore, the installation is the same as for any other adapter 84 Problem: The FDDI adapter cannot be found by the driver. 87 If this entry exists, then the FDDI adapter has been 92 The adapter can be checked using the diagnostic program 122 (5) FUNCTION OF THE ADAPTER LEDS 128 indicates that the ring is down. The green LED on the adapter now [all …]
|
| D | iphase.txt | 22 - All variants of Interphase ATM PCI (i)Chip adapter cards are supported, 43 d. Connect each adapter to a port on an ATM switch. The green 'Link' 44 LED on the front panel of the adapter will be on if the adapter is 57 4. Load the adapter hardware driver (ia driver) if it is built as a module 61 The yellow 'status' LED on the front panel of the adapter will blink 79 5.1 Configuration of adapter buffers 105 total adapter packet memory.
|
| /Documentation/media/kapi/ |
| D | cec-core.rst | 32 CEC Adapter Interface 35 The struct cec_adapter represents the CEC adapter hardware. It is created by 45 To create an adapter you need to pass the following information: 48 adapter operations which are called by the CEC framework and that you 52 will be stored in adap->priv and can be used by the adapter ops. 56 the name of the CEC adapter. Note: this name will be copied. 59 capabilities of the CEC adapter. These capabilities determine the 66 adapter can handle. Must be 1 <= available_las <= CEC_MAX_LOG_ADDRS. 89 unregister function will delete the adapter automatically once the last user 93 Implementing the Low-Level CEC Adapter [all …]
|
| /Documentation/networking/device_drivers/intel/ |
| D | igbvf.rst | 12 - Identifying Your Adapter 24 supplied with your Intel adapter. All hardware requirements listed apply to use 34 Identifying Your Adapter 36 For information on how to identify your adapter, and for the latest Intel 64 with a supported adapter, email the specific information related to the issue
|
| D | ixgbevf.rst | 13 - Identifying Your Adapter 21 supplied with your Intel adapter. All hardware requirements listed apply to use 25 Identifying Your Adapter 37 For information on how to identify your adapter, and for the latest Intel 66 with a supported adapter, email the specific information related to the issue
|
| D | e1000e.rst | 13 - Identifying Your Adapter 19 Identifying Your Adapter 21 For information on how to identify your adapter, and for the latest Intel 57 will program the adapter to send out a maximum of that many interrupts 105 will program the adapter to send at most that many interrupts per second, 291 - Intel(R) PRO/1000 Gigabit Server Adapter 329 In the default mode, an Intel(R) Ethernet Network Adapter using copper 331 the best setting. If the adapter cannot establish link with the link partner 332 using auto-negotiation, you may need to manually configure the adapter and link 345 always match the adapter settings. Adapter performance may suffer or your [all …]
|
| D | e1000.rst | 13 - Identifying Your Adapter 19 Identifying Your Adapter 22 For more information on how to identify your adapter, go to the Adapter & 25 http://support.intel.com/support/go/network/adapter/idguide.htm 28 website. In the search field, enter your adapter name or type, or use the 29 networking link on the left to search for your adapter: 31 http://support.intel.com/support/go/network/adapter/home.htm 58 advertised by the adapter. When this parameter is used, the Speed and 98 The driver can limit the amount of interrupts per second that the adapter 100 adapter that is based on the maximum amount of interrupts that the adapter [all …]
|
| /Documentation/i2c/busses/ |
| D | i2c-diolan-u2c.rst | 6 * Diolan U2C-12 I2C-USB adapter 16 This is the driver for the Diolan U2C-12 USB-I2C adapter. 18 The Diolan U2C-12 I2C-USB Adapter provides a low cost solution to connect
|
| D | i2c-parport.rst | 19 * (type=0) Philips adapter 20 * (type=1) home brew teletext adapter 21 * (type=2) Velleman K8000 adapter 22 * (type=3) ELV adapter 25 * (type=6) Barco LPT->DVI (K5800236) adapter 26 * (type=7) One For All JP1 parallel port adapter 41 Building your own adapter 44 If you want to build you own i2c-over-parallel-port adapter, here is 93 circuit the output buffers! So plugging the I2C adapter after loading 156 Legacy documentation for Velleman adapter [all …]
|
| D | i2c-amd8111.rst | 10 in the publicly available ACPI 2.0 specification, which the adapter 41 Note that for the 8111, there are two SMBus adapters. The SMBus 2.0 adapter 42 is supported by this driver, and the SMBus 1.0 adapter is supported by the
|
| /Documentation/s390/ |
| D | vfio-ap.rst | 9 of three AP instructions and from 1 up to 256 PCIe cryptographic adapter cards. 13 The AP adapter cards are exposed via the AP bus. The motivation for vfio-ap 24 * AP adapter 26 An AP adapter is an IBM Z adapter card that can perform cryptographic 29 the linux host. Each adapter is identified by a number from 0 to 255; however, 30 the maximum adapter number is determined by machine model and/or adapter type. 31 When installed, an AP adapter is accessed by AP instructions executed by any 34 The AP adapter cards are assigned to a given LPAR via the system's Activation 36 in the LPAR, the AP bus detects the AP adapter cards assigned to the LPAR and 37 creates a sysfs device for each assigned adapter. For example, if AP adapters [all …]
|
| /Documentation/ABI/testing/ |
| D | configfs-usb-gadget-midi | 7 index - index value for the USB MIDI adapter 8 id - ID string for the USB MIDI adapter
|
| /Documentation/networking/device_drivers/pensando/ |
| D | ionic.rst | 4 Linux Driver for the Pensando(R) Ethernet adapter family 13 - Identifying the Adapter 16 Identifying the Adapter
|
| /Documentation/devicetree/bindings/media/spi/ |
| D | sony-cxd2880.txt | 1 Sony CXD2880 DVB-T2/T tuner + demodulator driver SPI adapter 9 - vcc-supply: Optional phandle to the vcc regulator to power the adapter,
|
| /Documentation/devicetree/bindings/display/panel/ |
| D | armadeus,st0700-adapt.yaml | 7 title: Armadeus ST0700 Adapter 10 A Santek ST0700I5Y-RBSLW 7.0" WVGA (800x480) TFT with an adapter board.
|