Lines Matching full:flash
14 LED and flash LED devices provide the same basic functionality as current
15 regulators, but extended with LED and flash LED specific features like
16 blinking patterns, flash timeout, flash faults and external flash strobe mode.
122 For flash LED controllers with configurable current this property is
123 mandatory for the LEDs in the non-flash modes (e.g. torch or indicator).
148 # Required properties for flash LED child nodes:
149 flash-max-microamp:
151 Maximum flash LED supply current in microamperes. Required for flash LED
154 flash-max-timeout-us:
156 Maximum timeout in microseconds after which the flash LED is turned off.
157 Required for flash LED nodes with configurable timeout.
191 flash-max-microamp = <320000>;
192 flash-max-timeout-us = <500000>;