Lines Matching +full:0 +full:x2e
10 Addresses scanned: I2C 0x2c-0x2e
18 Addresses scanned: I2C 0x2c-0x2e
33 Set to non-zero to force some initializations (default is 0).
35 A "0" allows SMBus block data transactions if the host supports them. A "1"
36 disables SMBus block data transactions. The default is 0.
38 Configures in7 and in8 limit type, where 0 means absolute and non-zero
44 is "0,0".
46 A "0" configures the VID pins for V(ih) = 2.1V min, V(il) = 0.8V max.
50 inputs are not working, try changing this. The default value is "0".
90 from 0-255 where 0 indicates no throttling, and 255 indicates > 99.6%.
116 the override function is enabled. This value ranges from 0 to 15, with 0
124 which 1 indicates #VRD_HOT is asserted and 0 indicates it is negated. These
147 where 0 disables and 1 enables the manual control mode. The sysfs files pwm1
148 and pwm2 are used to set the manual duty cycle; each is an integer (0-255)
149 where 0 is 0% duty cycle, and 255 is 100%. Note that the duty cycle values
178 a "0" disables it. The h/w default is 0x0f (all temperatures bound).
181 0x01 Temp 1
182 0x02 Temp 2
183 0x04 Temp 3
184 0x08 Temp 4
185 0x10 #PROCHOT 1
186 0x20 #PROCHOT 2
187 0x40 #VRDHOT 1
188 0x80 #VRDHOT 2
202 1 0 - 25.00%
203 2 0 - 28.57%
217 Valid offsets are in the range 0C <= x <= 7.5C in 0.5C increments.
238 A spin-up cycle occurs when a PWM output is commanded from 0% duty cycle to
239 some value > 0%. The LM93 supports a minimum duty cycle during spin-up. These
249 0 (disabled, h/w default), 0.1, 0.25, 0.4, 0.7, 1.0, 2.0, 4.0
262 0 (disabled, h/w default) to 0.75 in 0.05 second intervals
298 vrdhot<n> 0 means negated, 1 means asserted