Lines Matching +full:1 +full:c
35 A "0" allows SMBus block data transactions if the host supports them. A "1"
47 A "1" configures the VID pins for V(ih) = 0.8V min, V(il) = 0.4V max.
124 which 1 indicates #VRD_HOT is asserted and 0 indicates it is negated. These
135 Smart tach mode is enabled by the driver by writing 1 or 2 (associating the
147 where 0 disables and 1 enables the manual control mode. The sysfs files pwm1
176 #PROCHOT 1 & 2, and #VRDHOT 1 & 2. The bindings are expressed as a bitmask
177 in the sysfs files pwm<n>_auto_channels, where a "1" enables the binding, and
181 0x01 Temp 1
185 0x10 #PROCHOT 1
187 0x40 #VRDHOT 1
193 temperature offsets. The base temperature is expressed in degrees C in the
195 degrees C, with the value of offset <i> for temperature value <n> being
197 is 40C:
202 1 0 - 25.00%
204 3 1 40C - 41C 32.14%
205 4 1 41C - 42C 35.71%
206 5 2 42C - 44C 39.29%
207 6 2 44C - 46C 42.86%
208 7 2 48C - 50C 46.43%
209 8 2 50C - 52C 50.00%
210 9 2 52C - 54C 53.57%
211 10 2 54C - 56C 57.14%
212 11 2 56C - 58C 71.43%
213 12 2 58C - 60C 85.71%
214 - - > 60C 100.00%
217 Valid offsets are in the range 0C <= x <= 7.5C in 0.5C increments.
269 This limit is expressed in degrees C in the sysfs files temp<n>_auto_boost.
273 C in the sysfs files temp<n>_auto_boost_hyst.
279 four tach input pins. GPIO0-GPIO3 correspond to (fan) tach 1-4, respectively.
298 vrdhot<n> 0 means negated, 1 means asserted
306 temp<n>_auto_offset[1-12] temperature channel offsets