Searched +full:dynamic +full:- +full:power +full:- +full:coefficient (Results 1 – 5 of 5) sorted by relevance
/Documentation/driver-api/thermal/ |
D | cpu-cooling-api.rst | 22 -------------------------------------------- 30 "thermal-cpufreq-%x". This api can support multiple instances of cpufreq 42 the name "thermal-cpufreq-%x" linking it with a device tree node, in 54 This interface function unregisters the "thermal-cpufreq-%x" cooling device. 58 2. Power models 61 The power API registration functions provide a simple power model for 62 CPUs. The current power is calculated as dynamic power (static power isn't 63 supported currently). This power model requires that the operating-points of 70 The dynamic power consumption of a processor depends on many factors. 73 - The time the processor spends running, consuming dynamic power, as [all …]
|
D | cpu-idle-cooling.rst | 1 .. SPDX-License-Identifier: GPL-2.0 8 ---------- 13 act on a cooling device to mitigate the dissipated power. When the 18 increase even after the dynamic leakage is reduced to its minimum by 20 to the static leakage. The only solution is to power down the 21 component, thus dropping the dynamic and static leakage that will 24 Last but not least, the system can ask for a specific power budget but 25 because of the OPP density, we can only choose an OPP with a power 26 budget lower than the requested one and under-utilize the CPU, thus 27 losing performance. In other words, one OPP under-utilizes the CPU [all …]
|
/Documentation/devicetree/bindings/thermal/ |
D | thermal-idle.yaml | 1 # SPDX-License-Identifier: (GPL-2.0-only OR BSD-2-Clause) 4 --- 5 $id: http://devicetree.org/schemas/thermal/thermal-idle.yaml# 6 $schema: http://devicetree.org/meta-schemas/core.yaml# 11 - Daniel Lezcano <daniel.lezcano@linaro.org> 22 const: thermal-idle 24 A thermal-idle node describes the idle cooling device properties to 27 '#cooling-cells': 31 the cooling-maps reference. The first cell is the minimum cooling state 34 duration-us: [all …]
|
D | thermal-cooling-devices.yaml | 1 # SPDX-License-Identifier: (GPL-2.0) 4 --- 5 $id: http://devicetree.org/schemas/thermal/thermal-cooling-devices.yaml# 6 $schema: http://devicetree.org/meta-schemas/core.yaml# 11 - Amit Kucheria <amitk@kernel.org> 20 - thermal-sensor: device that measures temperature, has SoC-specific bindings 21 - cooling-device: device used to dissipate heat either passively or actively 22 - thermal-zones: a container of the following node types used to describe all 27 There are essentially two ways to provide control on power dissipation: 28 - Passive cooling: by means of regulating device performance. A typical [all …]
|
/Documentation/devicetree/bindings/arm/ |
D | cpus.yaml | 1 # SPDX-License-Identifier: GPL-2.0 3 --- 5 $schema: http://devicetree.org/meta-schemas/core.yaml# 10 - Lorenzo Pieralisi <lorenzo.pieralisi@arm.com> 21 with updates for 32-bit and 64-bit ARM systems provided in this document. 30 - square brackets define bitfields, eg reg[7:0] value of the bitfield in 59 On 32-bit ARM v7 or later systems this property is 68 On ARM v8 64-bit systems this property is required 71 * If cpus node's #address-cells property is set to 2 79 * If cpus node's #address-cells property is set to 1 [all …]
|