Home
last modified time | relevance | path

Searched full:hysteresis (Results 1 – 25 of 69) sorted by relevance

123

/Documentation/hwmon/
Dlm77.rst28 critical (temp1_crit.) It also implements an hysteresis mechanism which
31 the limit and its hysteresis is always the same for all 3 limits.
35 * When setting a limit, its hysteresis will automatically follow, the
37 was 80 degrees C, and the hysteresis was 75 degrees C, and you change
38 the critical limit to 90 degrees C, then the hysteresis will
40 * All 3 hysteresis can't be set independently. We decided to make
44 hysteresis applies automatically to the low and high limits.
45 * The limits should be set before the hysteresis.
Demc1403.rst63 hysteresis mechanism which applies to all limits. The relative difference
65 difference between the limit and its hysteresis is always the same for
70 * When setting a limit, its hysteresis will automatically follow, the
72 was 80 degrees C, and the hysteresis was 75 degrees C, and you change
73 the critical limit to 90 degrees C, then the hysteresis will
75 * The hysteresis values can't be set independently. We decided to make
76 only temp1_crit_hyst writable, while all other hysteresis attributes
79 hysteresis applies automatically to all other limits.
80 * The limits should be set before the hysteresis.
Dadt7410.rst56 common hysteresis of 0°C - 15°C and a fault queue, ranging from 1 to 4 events.
74 Since the device uses one hysteresis value, which is an offset to minimum,
77 hysteresis.
88 temp#_min_hyst hysteresis for temperature minimum (read-only)
89 temp#_max_hyst hysteresis for temperature maximum (read/write)
90 temp#_crit_hyst hysteresis for critical temperature (read-only)
Djc42.rst126 There is also an hysteresis to control the thresholds for resetting alarms.
127 Per JC 42.4 specification, the hysteresis threshold can be configured to 0, 1.5,
128 3.0, and 6.0 degrees C. Configured hysteresis values will be rounded to those
129 limits. The chip supports only a single register to configure the hysteresis,
131 temp1_crit_hyst. Other hysteresis attributes are read-only.
146 temp1_crit_hyst Critical hysteresis temperature (RO or RW)
147 temp1_max_hyst Maximum hysteresis temperature (RO)
Dsht3x.rst58 When the temperature and humidity readings move back between the hysteresis
69 temp1_max_hyst: temperature hysteresis value for max limit
71 humidity1_max_hyst: humidity hysteresis value for max limit
73 temp1_min_hyst: temperature hysteresis value for min limit
75 humidity1_min_hyst: humidity hysteresis value for min limit
Dlm95245.rst39 hysteresis value common to both critical limits. To make life easier to
41 channel, but these values are of course linked. Only the local hysteresis
43 hysteresis.
Dlm95234.rst40 Each sensor has its own maximum limit, but the hysteresis is common to all
41 channels. The hysteresis is configurable with the tem1_max_hyst attribute and
42 affects the hysteresis on all channels. The first two external sensors also
Dtmp108.rst23 hysteresis value. (This driver does not support interrupts for the alert pin,
29 Hysteresis values can be set to 0, 1, 2, or 4C.
Dtmp513.rst37 For hysteresis value, only the first channel is writable. Writing to it
39 hysteresis value. The hysteresis is in degrees Celsius with a range of
Dintel-m10-bmc-hwmon.rst44 tempX_max_hyst Hysteresis for temperature maximum of the component
45 tempX_crit_hyst Hysteresis for temperature critical of the component
Dthmc50.rst48 register and Hysteresis register. Each value can be set and read to half-degree
51 until the temperature falls below the Hysteresis value. All temperatures are in
Dlm78.rst47 as soon as it drops below the Hysteresis value. A more useful behavior
48 can be found by setting the Hysteresis value to +127 degrees Celsius; in
/Documentation/devicetree/bindings/iio/light/
Dsharp,gp2ap002.yaml43 sharp,proximity-far-hysteresis:
46 Hysteresis setting for "far" object detection, this setting is
50 sharp,proximity-close-hysteresis:
53 Hysteresis setting for "close" object detection, this setting is
61 - sharp,proximity-far-hysteresis
62 - sharp,proximity-close-hysteresis
82 sharp,proximity-far-hysteresis = /bits/ 8 <0x2f>;
83 sharp,proximity-close-hysteresis = /bits/ 8 <0x0f>;
/Documentation/devicetree/bindings/thermal/
Dbrcm,sr-thermal.txt40 hysteresis = <0>;
52 hysteresis = <0>;
64 hysteresis = <0>;
76 hysteresis = <0>;
88 hysteresis = <0>;
100 hysteresis = <0>;
Dthermal-zones.yaml126 hysteresis:
129 An unsigned integer expressing the hysteresis delta with
133 (trip temperature - hysteresis). This potentially prevents a
166 - hysteresis
269 hysteresis = <2000>;
275 hysteresis = <2000>;
281 hysteresis = <1000>;
314 hysteresis = <2000>;
319 hysteresis = <2000>;
336 hysteresis = <2000>;
Dthermal-idle.yaml108 hysteresis = <2000>;
114 hysteresis = <2000>;
120 hysteresis = <2000>;
126 hysteresis = <2000>;
Dzx2967-thermal.txt59 hysteresis = <2000>;
65 hysteresis = <2000>;
71 hysteresis = <2000>;
Dqcom-spmi-temp-alarm.txt40 hysteresis = <2000>;
45 hysteresis = <2000>;
Dst,stm32-thermal.yaml64 hysteresis = <0>;
70 hysteresis = <0>;
Dmax77620_thermal.txt51 hysteresis = <0>;
57 hysteresis = <0>;
Drockchip-thermal.txt67 hysteresis = <2000>; /* millicelsius */
72 hysteresis = <2000>; /* millicelsius */
Dbrcm,ns-thermal.txt29 hysteresis = <0>;
/Documentation/ABI/testing/
Dsysfs-bus-iio-adc-hi843524 Hysteresis between low and high thresholds can not be lower then 2 and
27 If falling threshold results hysteresis to odd value then rising
44 Hysteresis between low and high thresholds can not be lower then 2 and
47 If rising threshold results hysteresis to odd value then falling
/Documentation/devicetree/bindings/sound/
Dnau8824.txt35 - nuvoton,sar-hysteresis: Button impedance measurement hysteresis.
82 nuvoton,sar-hysteresis = <0>;
Dnau8825.txt39 - nuvoton,sar-hysteresis: Button impedance measurement hysteresis.
94 nuvoton,sar-hysteresis = <1>;

123