24 The TI / Burr-Brown INA209 monitors voltage, current, and power on the high side
40 in0_input shunt voltage (mV)
41 in0_input_highest shunt voltage historical maximum reading (mV)
42 in0_input_lowest shunt voltage historical minimum reading (mV)
43 in0_reset_history reset shunt voltage history
44 in0_max shunt voltage max alarm limit (mV)
45 in0_min shunt voltage min alarm limit (mV)
46 in0_crit_max shunt voltage crit max alarm limit (mV)
47 in0_crit_min shunt voltage crit min alarm limit (mV)
48 in0_max_alarm shunt voltage max alarm limit exceeded
49 in0_min_alarm shunt voltage min alarm limit exceeded
50 in0_crit_max_alarm shunt voltage crit max alarm limit exceeded
51 in0_crit_min_alarm shunt voltage crit min alarm limit exceeded
53 in1_input bus voltage (mV)
54 in1_input_highest bus voltage historical maximum reading (mV)
55 in1_input_lowest bus voltage historical minimum reading (mV)
56 in1_reset_history reset bus voltage history
57 in1_max bus voltage max alarm limit (mV)
58 in1_min bus voltage min alarm limit (mV)
59 in1_crit_max bus voltage crit max alarm limit (mV)
60 in1_crit_min bus voltage crit min alarm limit (mV)
61 in1_max_alarm bus voltage max alarm limit exceeded
62 in1_min_alarm bus voltage min alarm limit exceeded
63 in1_crit_max_alarm bus voltage crit max alarm limit exceeded
64 in1_crit_min_alarm bus voltage crit min alarm limit exceeded
86 voltage can be provided using platform data. The driver uses platform data from