Lines Matching +full:hw +full:- +full:device +full:- +full:address
28 Description: (Read) Indicates the number of address comparator pairs that are
76 Description: (Read) Indicates the number of single-shot comparator controls that
155 Description: (RW) In non-secure state, each bit controls whether instruction
162 Description: (RW) Select which address comparator or pair (of comparators) to
175 Description: (RW) Used to setup single address comparator values.
181 Description: (RW) Used to setup address range comparator values.
290 non-secure exception levels.
303 Description: (Read) Print the current settings for the selected address
337 The value it taken directly from the HW.
344 (0x310). The value is taken directly from the HW.
351 (0x314). The value is taken directly from the HW.
358 (0xFB4). The value is taken directly from the HW.
365 (0xFB8). The value is taken directly from the HW.
371 Description: (Read) Print the content of the Device ID Register
372 (0xFC8). The value is taken directly from the HW.
378 Description: (Read) Print the content of the Device Architecture Register
380 from the HW.
386 Description: (Read) Print the content of the Device Type Register
387 (0xFCC). The value is taken directly from the HW.
394 (0xFE0). The value is taken directly from the HW.
401 (0xFE4). The value is taken directly from the HW.
408 (0xFE8). The value is taken directly from the HW.
415 (0xFEC). The value is taken directly from the HW.
435 The value is taken directly from the HW.
442 The value is taken directly from the HW.
448 Description: (Read) Returns the maximum size of the data value, data address,
449 VMID, context ID and instruction address in the trace unit
450 (0x1E8). The value is taken directly from the HW.
459 The value is taken directly from the HW.
466 The value is taken directly from the HW.
473 The value is taken directly from the HW.
480 trace stream. (0x180). The value is taken directly from the HW.
486 Description: (Read) Returns the number of P0 right-hand keys that the trace unit
487 can use (0x184). The value is taken directly from the HW.
493 Description: (Read) Returns the number of P1 right-hand keys that the trace unit
494 can use (0x188). The value is taken directly from the HW.
500 Description: (Read) Returns the number of special P1 right-hand keys that the
502 the HW.
508 Description: (Read) Returns the number of conditional P1 right-hand keys that
510 from the HW.
516 Description: (Read) Returns the number of special conditional P1 right-hand keys
518 directly from the HW.
525 trace session. Otherwise -1 indicates an unknown time source. Check