Lines Matching +full:wait +full:- +full:on +full:- +full:write
5 (RW) read or write TH and TL (Temperature High an Low) alarms.
7 (typical -55 degC to 125 degC), if not values will be trimmed
11 master level, refer to Documentation/w1/w1-generic.rst for
41 * '-xx': xx is kernel error when reading power status
51 (RW) get or set the device resolution (on supported devices,
55 values after power-on. Read or write are :
59 * '-xx': xx is kernel error when reading the resolution
62 Some DS18B20 clones are fixed in 12-bit resolution, so the
79 should retry later on.
82 conversion duration depend on the resolution (if
95 *read*: return 2 lines with the hexa output data sent on the
97 *write*:
118 * '-1':
119 conversion in progress on at least 1 sensor
125 trigger a conversion on each device
127 *write*:
128 'trigger': trigger a bulk read on all supporting
129 devices on the bus
132 immediately, the next access to temperature on this device
151 *write*:
171 Bit masks to read/write (bitwise OR):
177 (insufficient power) - return a conversion error.
180 after the conversion start and wait for 1's. In parasite
187 *write*: