Lines Matching +full:timebase +full:- +full:frequency
24 IRIG adjustments from external IRIG-B signal
42 IRIG signal is sent to the IRIG-B module
44 FREQ1 signal is sent to frequency counter 1
45 FREQ2 signal is sent to frequency counter 2
46 FREQ3 signal is sent to frequency counter 3
47 FREQ4 signal is sent to frequency counter 4
62 IRIG output is from the PHC, in IRIG-B format
64 GEN1 output is from frequency generator 1
65 GEN2 output is from frequency generator 2
66 GEN3 output is from frequency generator 3
67 GEN4 output is from frequency generator 4
95 frequency counter <X>.
97 What: /sys/class/timecard/ocpN/freqX/frequency
100 Description: (RO) Contains the measured frequency over the specified
106 Description: (RW) Specifies the number of seconds from 0-255 that the
107 frequency should be measured over. Write 0 to disable.
113 frequency generator <X>.
118 Description: (RO) Specifies the signal duty cycle as a percentage from 1-99.
164 a percentage from 1-99. Polarity is 1 or 0.
184 Description: (RW) An integer from 0-7 indicating the timecode format
185 of the IRIG-B output signal: B00<n>
241 taken from the UBX-NAV-TIMELS message.
290 offset in seconds, which is added to the TAI timebase for