Searched full:adapter (Results 1 – 25 of 197) sorted by relevance
12345678
| /Documentation/virt/kvm/devices/ |
| D | s390_flic.rst | 19 - register and modify adapter interrupt sources (KVM_DEV_FLIC_ADAPTER_*) 20 - modify AIS (adapter-interruption-suppression) mode state (KVM_DEV_FLIC_AISM) 21 - inject adapter interrupts on a specified adapter (KVM_DEV_FLIC_AIRQ_INJECT) 67 Register an I/O adapter interrupt source. Takes a kvm_s390_io_adapter 68 describing the adapter to register:: 78 id contains the unique id for the adapter, isc the I/O interruption subclass 79 to use, maskable whether this adapter may be masked (interrupts turned off), 81 further characteristics of the adapter. 85 - KVM_S390_ADAPTER_SUPPRESSIBLE: adapter is subject to AIS 86 (adapter-interrupt-suppression) facility. This flag only has an effect if [all …]
|
| /Documentation/networking/device_drivers/ethernet/cirrus/ |
| D | cs89x0.rst | 32 2.0 ADAPTER INSTALLATION and CONFIGURATION 33 2.1 CS8900-based Adapter Configuration 34 2.2 CS8920-based Adapter Configuration 45 5.2 Testing the Adapter 48 5.3 Using the Adapter's LEDs 73 CS8920-based adapters are similar to the CS8900-based adapter with additional 76 adapters. Refer to the "Adapter Configuration" section for details on 83 The CS8900/CS8920 Ethernet Adapter driver for Linux supports the Linux 111 * Cirrus Logic LAN (CS8900/20-based) Ethernet ISA Adapter 151 2. Adapter Installation and Configuration [all …]
|
| /Documentation/i2c/ |
| D | functionality.rst | 8 Because not every I2C or SMBus adapter implements everything in the 10 is implemented when it is given the option to attach to an adapter: 11 the client needs some way to check whether an adapter has the needed 57 emulated by a real I2C adapter (using 65 ADAPTER IMPLEMENTATION 68 When you write a new adapter driver, you will have to implement a 72 A typical SMBus-only adapter would list all the SMBus transactions it 75 static u32 piix4_func(struct i2c_adapter *adapter) 82 A typical full-I2C adapter would use the following (from the i2c-pxa 92 I2C_FUNC_I2C without any help from the adapter driver. The idea is [all …]
|
| D | i2c-topology.rst | 6 than a straight-forward I2C bus with one adapter and one or more devices. 22 These components are represented as I2C adapter trees by Linux, where 23 each adapter has a parent adapter (except the root adapter) and zero or 24 more child adapters. The root adapter is the actual adapter that issues 46 Mux-locked muxes does not lock the entire parent adapter during the 48 adapter are locked. Mux-locked muxes are mostly interesting if the 50 their tasks. Since the parent adapter is not fully locked during the 72 2. M1 locks muxes on its parent (the root adapter in this case). 76 adapter. 77 5. M1 feeds the I2C transfer from step 1 to its parent adapter as a [all …]
|
| D | fault-codes.rst | 38 Also, codes returned by adapter probe methods follow rules which are 67 SMBus adapter) needs some fault recovery (such as resetting), 102 Returned by an adapter when asked to perform an operation 105 For example, this would be returned when an adapter that 111 Similarly, if an I2C adapter can't execute all legal I2C 114 the adapter's functionality mask, since the assumption is 115 that if an adapter supports I2C it supports all of I2C.) 124 Returned when a transfer was requested using an adapter
|
| D | dev-interface.rst | 6 possible to access all devices on an adapter from userspace, through 9 Each registered I2C adapter gets a number, counting from 0. You can 10 examine /sys/class/i2c-dev/ to see what number corresponds to which adapter. 24 So let's say you want to access an I2C adapter from a C program. 30 Now, you have to decide which adapter you want to access. You should 32 Adapter numbers are assigned somewhat dynamically, so you can not 115 if the adapter has I2C_FUNC_10BIT_ADDR. 121 the adapter has I2C_FUNC_SMBUS_PEC; it is still safe if not, it just 125 Gets the adapter functionality and puts it in ``*funcs``. 129 Only valid if the adapter has I2C_FUNC_I2C. The argument is [all …]
|
| /Documentation/scsi/ |
| D | BusLogic.rst | 69 the BT-948 PCI Ultra SCSI Host Adapter, and then again for the BT-958 PCI Wide 70 Ultra SCSI Host Adapter in January 1996. This was mutually beneficial since 104 adapter hardware configuration, including the synchronous transfer parameters 116 adapter will attempt to negotiate for 20.0 mega-transfers/second. 121 adapter will attempt to negotiate for 10.0 mega-transfers/second. 126 adapter will attempt to negotiate for 5.0 mega-transfers/second. 138 adapter's SCSI ID is represented by the "#". 151 addition, BusLogic's Strict Round Robin Mode is used to optimize host adapter 157 is determined automatically based on the host adapter's total queue depth and 159 addition, tagged queuing is automatically disabled whenever the host adapter [all …]
|
| /Documentation/networking/device_drivers/fddi/ |
| D | skfp.rst | 22 (5) INCLUSION OF THE ADAPTER IN SYSTEM START 24 (7) FUNCTION OF THE ADAPTER LEDS 32 network adapter. 42 Chapter 5: Shows the changed functionality of the adapter LEDs. 77 Therefore, the installation is the same as for any other adapter 91 The FDDI adapter cannot be found by the driver. 98 If this entry exists, then the FDDI adapter has been 105 The adapter can be checked using the diagnostic program 140 5. Function of the Adapter LEDs 146 indicates that the ring is down. The green LED on the adapter now [all …]
|
| /Documentation/driver-api/media/ |
| D | cec-core.rst | 32 CEC Adapter Interface 35 The struct cec_adapter represents the CEC adapter hardware. It is created by 46 To create an adapter you need to pass the following information: 49 adapter operations which are called by the CEC framework and that you 53 will be stored in adap->priv and can be used by the adapter ops. 57 the name of the CEC adapter. Note: this name will be copied. 60 capabilities of the CEC adapter. These capabilities determine the 67 adapter can handle. Must be 1 <= available_las <= CEC_MAX_LOG_ADDRS. 91 unregister function will delete the adapter automatically once the last user 95 Implementing the Low-Level CEC Adapter [all …]
|
| /Documentation/networking/device_drivers/ethernet/intel/ |
| D | ixgbevf.rst | 13 - Identifying Your Adapter 21 supplied with your Intel adapter. All hardware requirements listed apply to use 25 Identifying Your Adapter 37 For information on how to identify your adapter, and for the latest Intel 61 with a supported adapter, email the specific information related to the issue
|
| D | igbvf.rst | 12 - Identifying Your Adapter 24 supplied with your Intel adapter. All hardware requirements listed apply to use 34 Identifying Your Adapter 36 For information on how to identify your adapter, and for the latest Intel 59 with a supported adapter, email the specific information related to the issue
|
| D | e1000e.rst | 13 - Identifying Your Adapter 19 Identifying Your Adapter 21 For information on how to identify your adapter, and for the latest Intel 57 will program the adapter to send out a maximum of that many interrupts 105 will program the adapter to send at most that many interrupts per second, 291 - Intel(R) PRO/1000 Gigabit Server Adapter 329 In the default mode, an Intel(R) Ethernet Network Adapter using copper 331 the best setting. If the adapter cannot establish link with the link partner 332 using auto-negotiation, you may need to manually configure the adapter and link 345 always match the adapter settings. Adapter performance may suffer or your [all …]
|
| D | e1000.rst | 13 - Identifying Your Adapter 19 Identifying Your Adapter 22 For more information on how to identify your adapter, go to the Adapter & 25 http://support.intel.com/support/go/network/adapter/idguide.htm 28 website. In the search field, enter your adapter name or type, or use the 29 networking link on the left to search for your adapter: 31 http://support.intel.com/support/go/network/adapter/home.htm 58 advertised by the adapter. When this parameter is used, the Speed and 98 The driver can limit the amount of interrupts per second that the adapter 100 adapter that is based on the maximum amount of interrupts that the adapter [all …]
|
| /Documentation/networking/device_drivers/ethernet/neterion/ |
| D | s2io.rst | 11 - 2. Identifying the adapter/interface 27 2. Identifying the adapter/interface 30 a. Insert the adapter(s) in your system. 41 eth3: Neterion Xframe I 10GbE adapter (rev 3), Version 2.0.9.1, Intr type INTA 42 eth4: Neterion Xframe II 10GbE adapter (rev 2), Version 2.0.9.1, Intr type INTA 45 The above messages identify the adapter type(Xframe I/II), adapter revision, 50 To associate an interface with a physical adapter use "ethtool -p <ethX>". 51 The corresponding adapter's LED will blink multiple times.
|
| /Documentation/i2c/busses/ |
| D | i2c-diolan-u2c.rst | 6 * Diolan U2C-12 I2C-USB adapter 16 This is the driver for the Diolan U2C-12 USB-I2C adapter. 18 The Diolan U2C-12 I2C-USB Adapter provides a low cost solution to connect
|
| D | i2c-parport.rst | 19 * (type=0) Philips adapter 20 * (type=1) home brew teletext adapter 21 * (type=2) Velleman K8000 adapter 22 * (type=3) ELV adapter 25 * (type=6) Barco LPT->DVI (K5800236) adapter 26 * (type=7) One For All JP1 parallel port adapter 41 Building your own adapter 44 If you want to build you own i2c-over-parallel-port adapter, here is 93 circuit the output buffers! So plugging the I2C adapter after loading 156 Legacy documentation for Velleman adapter [all …]
|
| D | i2c-amd8111.rst | 10 in the publicly available ACPI 2.0 specification, which the adapter 41 Note that for the 8111, there are two SMBus adapters. The SMBus 2.0 adapter 42 is supported by this driver, and the SMBus 1.0 adapter is supported by the
|
| /Documentation/devicetree/bindings/power/supply/ |
| D | bq24735.yaml | 24 description: AC adapter plug event interrupt 30 This GPIO is optionally used to read the AC adapter status. This is a Host GPIO 32 Note: for backwards compatibility reasons, the GPIO must be active on AC adapter 33 absence despite ACOK being active (high) on AC adapter presence. 68 If 'interrupts' is not specified, poll AC adapter presence with this interval (milliseconds).
|
| /Documentation/arch/s390/ |
| D | vfio-ap.rst | 9 of three AP instructions and from 1 up to 256 PCIe cryptographic adapter cards. 13 The AP adapter cards are exposed via the AP bus. The motivation for vfio-ap 24 * AP adapter 26 An AP adapter is an IBM Z adapter card that can perform cryptographic 29 the linux host. Each adapter is identified by a number from 0 to 255; however, 30 the maximum adapter number is determined by machine model and/or adapter type. 31 When installed, an AP adapter is accessed by AP instructions executed by any 34 The AP adapter cards are assigned to a given LPAR via the system's Activation 36 in the LPAR, the AP bus detects the AP adapter cards assigned to the LPAR and 37 creates a sysfs device for each assigned adapter. For example, if AP adapters [all …]
|
| /Documentation/admin-guide/blockdev/ |
| D | paride.rst | 17 a parallel-port adapter chip added in. Some of the original parallel port 19 (The Iomega PPA-3 adapter used in the ZIP drives is an example of this 21 The adapter chip reproduces a small ISA or IDE bus in the external device 31 find a standard ATAPI CD-ROM drive, a power supply, and a single adapter 61 parallel port IDE adapter chips. Thanks to the interest and encouragement of 63 known adapter protocols: 68 comm DataStor (old-type) "commuter" adapter (TW) 77 ktti KT Technology PHd adapter (SG) 91 If you do not know what kind of parallel port adapter is used in your drive, 94 the adapter chip itself. That's usually sufficient to identify the [all …]
|
| /Documentation/userspace-api/media/cec/ |
| D | cec-ioc-adap-g-conn-info.rst | 39 by the kernel with the info provided by the adapter's driver. This ioctl 53 - The type of connector this adapter is associated with. 75 - No connector is associated with the adapter/the information is not 81 - Indicates that a DRM connector is associated with this adapter.
|
| /Documentation/networking/device_drivers/atm/ |
| D | iphase.rst | 30 - All variants of Interphase ATM PCI (i)Chip adapter cards are supported, 53 d. Connect each adapter to a port on an ATM switch. The green 'Link' 54 LED on the front panel of the adapter will be on if the adapter is 69 4. Load the adapter hardware driver (ia driver) if it is built as a module 74 The yellow 'status' LED on the front panel of the adapter will blink 92 5.1 Configuration of adapter buffers 122 total adapter packet memory.
|
| /Documentation/devicetree/bindings/media/spi/ |
| D | sony-cxd2880.txt | 1 Sony CXD2880 DVB-T2/T tuner + demodulator driver SPI adapter 9 - vcc-supply: Optional phandle to the vcc regulator to power the adapter,
|
| /Documentation/ABI/testing/ |
| D | configfs-usb-gadget-midi | 8 index index value for the USB MIDI adapter 9 id ID string for the USB MIDI adapter
|
| /Documentation/devicetree/bindings/display/panel/ |
| D | armadeus,st0700-adapt.yaml | 7 title: Armadeus ST0700 Adapter 10 A Santek ST0700I5Y-RBSLW 7.0" WVGA (800x480) TFT with an adapter board.
|
12345678