/Documentation/devicetree/bindings/memory-controllers/
Dst,stm32-fmc2-ebi-props.yaml1 # SPDX-License-Identifier: (GPL-2.0 OR BSD-2-Clause)
3 ---
4 $id: http://devicetree.org/schemas/memory-controllers/st,stm32-fmc2-ebi-props.yaml#
5 $schema: http://devicetree.org/meta-schemas/core.yaml#
10 - Christophe Kerello <christophe.kerello@foss.st.com>
11 - Marek Vasut <marex@denx.de>
14 st,fmc2-ebi-cs-transaction-type:
33 st,fmc2-ebi-cs-cclk-enable:
40 st,fmc2-ebi-cs-mux-enable:
41 description: Address/Data multiplexed on databus (valid only with
[all …]
Dmvebu-devbus.txt9 - compatible: Armada 370/XP SoC are supported using the
10 "marvell,mvebu-devbus" compatible string.
13 "marvell,orion-devbus" compatible string.
15 - reg: A resource specifier for the register space.
16 This is the base address of a chip select within
20 - #address-cells: Must be set to 1
21 - #size-cells: Must be set to 1
22 - ranges: Must be set up to reflect the memory layout with four
23 integer values for each chip-select line in use:
24 0 <physical address of mapping> <size>
[all …]
Dti,gpmc-child.yaml1 # SPDX-License-Identifier: (GPL-2.0-only OR BSD-2-Clause)
3 ---
4 $id: http://devicetree.org/schemas/memory-controllers/ti,gpmc-child.yaml#
5 $schema: http://devicetree.org/meta-schemas/core.yaml#
10 - Tony Lindgren <tony@atomide.com>
11 - Roger Quadros <rogerq@kernel.org>
24 gpmc,sync-clk-ps:
28 # Chip-select signal timings corresponding to GPMC_CONFIG2:
29 gpmc,cs-on-ns:
33 gpmc,cs-rd-off-ns:
[all …]
/Documentation/devicetree/bindings/mtd/
Dst,stm32-fmc2-nand.yaml1 # SPDX-License-Identifier: (GPL-2.0-only OR BSD-2-Clause)
3 ---
4 $id: http://devicetree.org/schemas/mtd/st,stm32-fmc2-nand.yaml#
5 $schema: http://devicetree.org/meta-schemas/core.yaml#
10 - Christophe Kerello <christophe.kerello@foss.st.com>
15 - st,stm32mp15-fmc2
16 - st,stm32mp1-fmc2-nfc
17 - st,stm32mp25-fmc2-nfc
28 - description: tx DMA channel
29 - description: rx DMA channel
[all …]
Dgpio-control-nand.txt4 read/write the NAND commands and data and GPIO pins for the control
8 - compatible : "gpio-control-nand"
9 - reg : should specify localbus chip select and size used for the chip. The
10 resource describes the data bus connected to the NAND flash and all accesses
12 - #address-cells, #size-cells : Must be present if the device has sub-nodes
14 - gpios : Specifies the GPIO pins to control the NAND device. The order of
18 - bank-width : Width (in bytes) of the device. If not present, the width
20 - chip-delay : chip dependent delay for transferring data from array to
22 - gpio-control-nand,io-sync-reg : A 64-bit physical address for a read
24 the GPIO's and the NAND flash data bus. If present, then after changing
[all …]
/Documentation/misc-devices/
Dmax6875.rst13 Datasheet: http://pdfserv.maxim-ic.com/en/ds/MAX6874-MAX6875.pdf
19 -----------
21 The Maxim MAX6875 is an EEPROM-programmable power-supply sequencer/supervisor.
33 - vin gpi vout
43 -------------
45 eeprom - 512 bytes of user-defined EEPROM space.
49 ---------------
55 The driver does not probe any address, so you explicitly instantiate the
61 $ echo max6875 0x50 > /sys/bus/i2c/devices/i2c-0/new_device
63 The MAX6874/MAX6875 ignores address bit 0, so this driver attaches to multiple
[all …]
Duacce.rst1 .. SPDX-License-Identifier: GPL-2.0
4 ---------------------
6 Uacce (Unified/User-space-access-intended Accelerator Framework) targets to
8 So accelerator can access any data structure of the main cpu.
9 This differs from the data sharing between cpu and io device, which share
10 only data content rather than address.
11 Because of the unified address, hardware and user space of process can
12 share the same virtual address in the communication.
42 ------------
44 Uacce is the kernel module, taking charge of iommu and address sharing.
[all …]
/Documentation/arch/sparc/oradax/
Ddax-hv-api.txt3 Publication date 2017-09-25 08:21
5 Extracted via "pdftotext -f 547 -l 572 -layout sun4v_20170925.pdf"
13 …The following APIs provide access via the Hypervisor to hardware assisted data processing function…
16 live-migration and other system management activities.
18 36.1. Data Analytics Accelerator
19 …The Data Analytics Accelerator (DAX) functionality is a collection of hardware coprocessors that p…
20 …high speed processoring of database-centric operations. The coprocessors may support one or more of
21 …the following data query operations: search, extraction, compression, decompression, and translati…
24 …The DAX is a virtual device to sun4v guests, with supported data operations indicated by the virtu…
28 …e Completion Area and, unless execution order is specifically restricted through the use of serial-
[all …]
/Documentation/scsi/
Dcxgb3i.rst1 .. SPDX-License-Identifier: GPL-2.0
11 series of products) support iSCSI acceleration and iSCSI Direct Data Placement
16 - iSCSI PDU digest generation and verification
19 Data digest into the PDUs.
21 Data digest of the PDUs.
23 - Direct Data Placement (DDP)
25 S3 h/w can directly place the iSCSI Data-In or Data-Out PDU's
26 payload into pre-posted final destination host-memory buffers based
27 on the Initiator Task Tag (ITT) in Data-In or Target Task Tag (TTT)
28 in Data-Out PDUs.
[all …]
/Documentation/devicetree/bindings/soc/fsl/cpm_qe/
Dcpm.txt10 - compatible : "fsl,cpm1", "fsl,cpm2", or "fsl,qe".
11 - reg : A 48-byte region beginning with CPCR.
15 #address-cells = <1>;
16 #size-cells = <1>;
17 #interrupt-cells = <2>;
18 compatible = "fsl,mpc8272-cpm", "fsl,cpm2";
24 - fsl,cpm-command : This value is ORed with the opcode and command flag
27 - fsl,cpm-brg : Indicates which baud rate generator the device
32 - reg : Unless otherwise specified, the first resource represents the
36 * Multi-User RAM (MURAM)
[all …]
Dfsl,qe-muram.yaml1 # SPDX-License-Identifier: (GPL-2.0-only OR BSD-2-Clause)
3 ---
4 $id: http://devicetree.org/schemas/soc/fsl/cpm_qe/fsl,qe-muram.yaml#
5 $schema: http://devicetree.org/meta-schemas/core.yaml#
7 title: Freescale QUICC Engine Multi-User RAM (MURAM)
10 - Frank Li <Frank.Li@nxp.com>
12 description: Multi-User RAM (MURAM)
17 - const: fsl,qe-muram
18 - const: fsl,cpm-muram
23 "#address-cells":
[all …]
/Documentation/admin-guide/device-mapper/
Dvdo-design.rst1 .. SPDX-License-Identifier: GPL-2.0-only
4 Design of dm-vdo
7 The dm-vdo (virtual data optimizer) target provides inline deduplication,
8 compression, zero-block elimination, and thin provisioning. A dm-vdo target
12 production environments ever since. It was made open-source in 2017 after
14 dm-vdo. For usage, see vdo.rst in the same directory as this file.
25 The design of dm-vdo is based on the idea that deduplication is a two-part
26 problem. The first is to recognize duplicate data. The second is to avoid
27 storing multiple copies of those duplicates. Therefore, dm-vdo has two main
29 duplicate data, and a data store with a reference counted block map that
[all …]
/Documentation/hwmon/
Dabituguru-datasheet.rst6 datasheet from Abit. The data I have got on uGuru have I assembled through
11 mailing Windbond for help won't give any useful data about uGuru, as it is
14 Olle Sandberg <ollebull@gmail.com>, 2005-05-25
27 Hans de Goede <j.w.r.degoede@hhs.nl>, 28-01-2006
33 As far as known the uGuru is always placed at and using the (ISA) I/O-ports
34 0xE0 and 0xE4, so we don't have to scan any port-range, just check what the two
35 ports are holding for detection. We will refer to 0xE0 as CMD (command-port)
36 and 0xE4 as DATA because Abit refers to them with these names.
38 If DATA holds 0x00 or 0x08 and CMD holds 0x00 or 0xAC an uGuru could be
39 present. We have to check for two different values at data-port, because
[all …]
/Documentation/networking/
Doa-tc6-framework.rst1 .. SPDX-License-Identifier: GPL-2.0+
4 OPEN Alliance 10BASE-T1x MAC-PHY Serial Interface (TC6) Framework Support
8 ------------
11 single pair of conductors. The 10BASE-T1L (Clause 146) is a long reach
12 PHY supporting full duplex point-to-point operation over 1 km of single
13 balanced pair of conductors. The 10BASE-T1S (Clause 147) is a short reach
14 PHY supporting full / half duplex point-to-point operation over 15 m of
21 works in conjunction with the 10BASE-T1S PHY operating in multidrop mode.
23 The aforementioned PHYs are intended to cover the low-speed / low-cost
29 The MAC-PHY solution integrates an IEEE Clause 4 MAC and a 10BASE-T1x PHY
[all …]
/Documentation/staging/
Drpmsg.rst17 flavor of real-time OS.
19 OMAP4, for example, has dual Cortex-A9, dual Cortex-M3 and a C64x+ DSP.
20 Typically, the dual cortex-A9 is running Linux in a SMP configuration,
25 hardware accelerators, and therefore are often used to offload CPU-intensive
28 These remote processors could also be used to control latency-sensitive
34 hardware accessible only by the remote processor, reserving kernel-controlled
37 Rpmsg is a virtio-based messaging bus that allows kernel drivers to communicate
56 and have a local ("source") rpmsg address, and remote ("destination") rpmsg
57 address.
60 a unique rpmsg local address (a 32-bit integer). This way when inbound messages
[all …]
/Documentation/admin-guide/mm/
Dconcepts.rst7 systems from MMU-less microcontrollers to supercomputers. The memory
12 address to a physical address.
23 address ranges. Besides, different CPU architectures, and even
25 of how these address ranges are defined.
33 protection and controlled sharing of data between processes.
36 address. When the CPU decodes an instruction that reads (or
38 address encoded in that instruction to a `physical` address that the
49 translation from a virtual address used by programs to the physical
50 memory address. The page tables are organized hierarchically.
56 register. When the CPU performs the address translation, it uses this
[all …]
/Documentation/devicetree/bindings/bus/
Dnvidia,tegra20-gmi.txt10 - compatible : Should contain one of the following:
11 For Tegra20 must contain "nvidia,tegra20-gmi".
12 For Tegra30 must contain "nvidia,tegra30-gmi".
13 - reg: Should contain GMI controller registers location and length.
14 - clocks: Must contain an entry for each entry in clock-names.
15 - clock-names: Must include the following entries: "gmi"
16 - resets : Must contain an entry for each entry in reset-names.
17 - reset-names : Must include the following entries: "gmi"
18 - #address-cells: The number of cells used to represent physical base
19 addresses in the GMI address space. Should be 2.
[all …]
/Documentation/arch/s390/
Dmonreader.rst5 Date : 2004-Nov-26
33 See also "CP Command and Utility Reference" (SC24-6081-00) for more information
35 and Administration" (SC24-6116-00) for more information on DCSSes.
38 -----------
40 guest virtual storage around the address range of the DCSS.
45 address 0MB, the second is 200MB in size and begins at address 200MB,
50 -----------
51 Your guest virtual storage has to end below the starting address of the DCSS
53 value greater than the ending address of the DCSS.
78 Refer to the "z/VM Performance" book (SC24-6109-00) on how to create a monitor
[all …]
/Documentation/devicetree/bindings/nvmem/
Dsc27xx-efuse.txt4 - compatible: Should be one of the following.
5 "sprd,sc2720-efuse"
6 "sprd,sc2721-efuse"
7 "sprd,sc2723-efuse"
8 "sprd,sc2730-efuse"
9 "sprd,sc2731-efuse"
10 - reg: Specify the address offset of efuse controller.
11 - hwlocks: Reference to a phandle of a hwlock provider node.
13 = Data cells =
22 spi-max-frequency = <26000000>;
[all …]
/Documentation/devicetree/bindings/gpio/
Dnetxbig-gpio-ext.txt5 - compatible: "lacie,netxbig-gpio-ext".
6 - addr-gpios: GPIOs representing the address register (LSB -> MSB).
7 - data-gpios: GPIOs representing the data register (LSB -> MSB).
8 - enable-gpio: latches the new configuration (address, data) on raising edge.
12 netxbig_gpio_ext: netxbig-gpio-ext {
13 compatible = "lacie,netxbig-gpio-ext";
15 addr-gpios = <&gpio1 15 GPIO_ACTIVE_HIGH
18 data-gpios = <&gpio1 12 GPIO_ACTIVE_HIGH
21 enable-gpio = <&gpio0 29 GPIO_ACTIVE_HIGH>;
/Documentation/i2c/busses/
Di2c-mlxcpld.rst2 Driver i2c-mlxcpld
11 - Master mode.
12 - One physical bus.
13 - Polling mode.
20 - Receive Byte/Block.
21 - Send Byte/Block.
22 - Read Byte/Block.
23 - Write Byte/Block.
28 CPBLTY 0x0 - capability reg.
29 Bits [6:5] - transaction length. b01 - 72B is supported,
[all …]
/Documentation/i2c/
Dsmbus-protocol.rst24 single data byte, the functions using SMBus protocol operation names execute
44 Addr (7 bits) I2C 7 bit address. Note that this can be expanded to
45 get a 10 bit I2C address.
46 Comm (8 bits) Command byte, a data byte which often selects a register on
48 Data (8 bits) A plain data byte. DataLow and DataHigh represent the low and
50 Count (8 bits) A data byte containing the length of a block operation.
52 [..] Data sent by I2C device, as opposed to data sent by the host
77 S Addr Rd [A] [Data] NA P
92 S Addr Wr [A] Data [A] P
105 S Addr Wr [A] Comm [A] Sr Addr Rd [A] [Data] NA P
[all …]
/Documentation/admin-guide/RAS/
Daddress-translation.rst1 .. SPDX-License-Identifier: GPL-2.0
3 Address translation
7 -------
9 Zen-based AMD systems include a Data Fabric that manages the layout of
12 These devices may provide a "normalized", i.e. device physical, address
14 a system physical address for the kernel to action on the memory.
16 AMD Address Translation Library (CONFIG_AMD_ATL) provides translation for
19 Glossary of acronyms used in address translation for Zen-based systems
22 * COD = Cluster-on-Die
24 * DF = Data Fabric
/Documentation/networking/device_drivers/ethernet/davicom/
Ddm9000.rst1 .. SPDX-License-Identifier: GPL-2.0
9 Ben Dooks <ben@simtec.co.uk> <ben-linux@fluff.org>
13 ------------
15 This file describes how to use the DM9000 platform-device based network driver
25 ----------------------------
29 1) The physical address of the address register
30 2) The physical address of the data register
34 two address regions is important (the driver expects these to be address
35 and then data).
37 An example from arch/arm/mach-s3c/mach-bast.c is::
[all …]
/Documentation/hid/
Dhid-alps.rst6 ------------
19 --------------
33 18 wDataRegister 0006 Identifier for Data Register
42 ---------
45 ReportID-1 (Input Reports) (HIDUsage-Mouse) for TP&SP
46 ReportID-2 (Input Reports) (HIDUsage-keyboard) for TP
47 ReportID-3 (Input Reports) (Vendor Usage: Max 10 finger data) for TP
48 ReportID-4 (Input Reports) (Vendor Usage: ON bit data) for GP
49 ReportID-5 (Feature Reports) Feature Reports
50 ReportID-6 (Input Reports) (Vendor Usage: StickPointer data) for SP
[all …]