Searched full:alert (Results 1 – 25 of 52) sorted by relevance
123
| /Documentation/devicetree/bindings/hwmon/ |
| D | max6697.txt | 30 - alert-mask 31 Alert bit mask. Alert disabled for bits set. 33 If not specified, alert will be enabled for all channels. 62 alert-mask = <0x72>;
|
| D | ti,ina2xx.yaml | 69 ti,alert-polarity-active-high: 70 description: Alert pin is asserted based on the value of Alert polarity Bit 74 the alert polarity to active-high. 99 ti,alert-polarity-active-high;
|
| D | adi,adm1177.yaml | 31 the current reading and overcurrent alert is disabled. 35 Specifies the current level at which an over current alert occurs. 36 If not provided, the overcurrent alert is configured to max ADC range
|
| D | ti,tmp108.yaml | 15 alert functions. 27 - description: alert interrupt
|
| D | ti,ina3221.yaml | 63 The INA3221 has a critical alert pin that can be controlled by the 70 shunt-voltage sum limit value is exceeded, the critical alert pin 76 triggering the critical alert pin, then this property can be used
|
| /Documentation/hwmon/ |
| D | ina3221.rst | 35 curr[123]_crit Critical alert current(mA) setting, activates the 38 curr[123]_crit_alarm Critical alert current limit exceeded 39 curr[123]_max Warning alert current(mA) setting, activates the 42 curr[123]_max_alarm Warning alert current limit exceeded 49 curr4_crit Critical alert current(mA) setting for sum of current 54 curr4_crit_alarm Critical alert current limit exceeded for sum of
|
| D | max6639.rst | 38 temp1_crit RW Set ALERT temperature for input 1 39 temp2_crit RW Set ALERT temperature for input 2 51 temp1_crit_alarm R Alarm on ALERT temperature on channel 1 52 temp2_crit_alarm R Alarm on ALERT temperature on channel 2
|
| D | lm90.rst | 494 * Filter and alert configuration register at 0xBF. 495 * ALERT is triggered by temperatures over critical limits. 506 * Consecutive alert register at 0x22. 509 * ALERT is triggered by open remote sensor. 568 * Filter and alert configuration register at 0xBF 595 SMBus Alert Support 598 This driver has basic support for SMBus alert. When an alert is received, 602 Semiconductor chips (NCT1008) do not implement the SMBus alert protocol 603 properly so additional care is needed: the ALERT output is disabled when 604 an alert is received, and is re-enabled only when the alarm is gone.
|
| D | tmp108.rst | 21 The Texas Instruments TMP108 implements one temperature sensor. An alert pin 23 hysteresis value. (This driver does not support interrupts for the alert pin,
|
| D | sht3x.rst | 62 reading exceeds the configured limits, the alert attribute is set to 1 and 63 the alert pin on the sensor is set to high. 65 values, the alert bit is set to 0 and the alert pin on the sensor is set to
|
| D | lm63.rst | 72 Note that the pin used for fan monitoring is shared with an alert out 77 for fan monitoring and alert out. On the LM64, monitoring is always enabled;
|
| D | ibmpowernv.rst | 35 fanX_min Threshold RPM for alert generation. 40 tempX_max Threshold ambient temperature for alert generation.
|
| D | sbtsi_temp.rst | 42 corresponding alert signals.
|
| D | max31760.rst | 34 shut down the system. A dedicated ALERT pin reports that either a local or 67 temp[1-2]_max Temperature max value. Asserts "ALERT" pin when exceeded
|
| /Documentation/devicetree/bindings/power/supply/ |
| D | maxim,max17040.yaml | 31 maxim,alert-low-soc-level: 36 The alert threshold that sets the state of charge level (%) where an interrupt is generated. 69 Use this property to use alert low SoC level interrupt as wake up source. 87 maxim,alert-low-soc-level = <10>; 100 maxim,alert-low-soc-level = <10>; 125 maxim,alert-low-soc-level = <10>;
|
| D | microchip,ucs1002.yaml | 26 - const: alert 28 - const: alert 49 interrupt-names = "a_det", "alert";
|
| D | battery.yaml | 113 - description: alert when ambient temperature is lower than this value 114 - description: alert when ambient temperature is higher than this value 116 alert-celsius: 119 - description: alert when battery temperature is lower than this value 120 - description: alert when battery temperature is higher than this value 172 alert-celsius = <0 40>;
|
| /Documentation/devicetree/bindings/usb/ |
| D | st,typec-stm32g0.yaml | 11 typically using the UCSI protocol over I2C, with a dedicated alert 60 /* Alert pin on GPIO PE12 */
|
| /Documentation/devicetree/bindings/iio/adc/ |
| D | adi,ad7280a.yaml | 31 adi,voltage-alert-last-chan: 75 adi,voltage-alert-last-chan = <5>;
|
| D | adi,ad7091r5.yaml | 59 be attached to ALERT/BUSY/GPO0 pin. 69 # AD7091R-2 does not have ALERT/BUSY/GPO pin
|
| D | adi,ad4695.yaml | 90 - description: Signal coming from the BSY_ALT_GP0 pin (ALERT or BUSY). 91 - description: Signal coming from the GP2 pin (ALERT).
|
| /Documentation/power/ |
| D | power_supply_class.rst | 186 minimum capacity alert value in percents. 188 maximum capacity alert value in percents. 195 minimum battery temperature alert. 197 maximum battery temperature alert. 201 minimum ambient temperature alert. 203 maximum ambient temperature alert.
|
| /Documentation/i2c/ |
| D | smbus-protocol.rst | 267 SMBus Alert 270 SMBus Alert was introduced in Revision 1.0 of the specification. 272 The SMBus alert protocol allows several SMBus slave devices to share a 278 * I2C bus drivers which support SMBus alert should call 279 i2c_new_smbus_alert_device() to install SMBus alert support. 281 the optional alert() callback.
|
| D | slave-testunit-backend.rst | 213 The following command will trigger the alert with a response of 0xc9 after 1 230 If the host does not respond to the alert within 1 second, the test will be 234 on the SMBus Alert Response Address (0x0c). It will reassign its original
|
| /Documentation/devicetree/bindings/memory-controllers/ti/ |
| D | emif.txt | 56 - hw-caps-temp-alert : Have this property if the controller 69 hw-caps-temp-alert;
|
123