Searched full:drop (Results 1 – 25 of 165) sorted by relevance
1234567
| /Documentation/networking/devlink/ |
| D | devlink-trap.rst | 38 port). This is especially useful for drop traps (see :ref:`Trap-Types`) 62 | devlink | (non-drop traps) 91 * ``drop``: Trapped packets were dropped by the underlying device. Packets 103 the kernel's Rx path, but not reported to the kernel's drop monitor. 115 * ``drop``: The packet is dropped by the underlying device and a copy is not 135 - ``drop`` 136 - Traps incoming packets that the device decided to drop because of a 139 - ``drop`` 140 - Traps incoming packets that the device decided to drop in case of VLAN 144 - ``drop`` [all …]
|
| D | prestera.rst | 116 - ``drop`` 119 - ``drop`` 122 - ``drop`` 125 - ``drop`` 128 - ``drop`` 131 - ``drop`` 134 - ``drop`` 137 - ``drop`` 140 - ``drop`` 141 …- Drops non-conforming packets (dropped by Ingress policer, metering drop), e.g. packet rate excee…
|
| D | mlxsw.rst | 95 - ``drop`` 96 - Traps packets that the device decided to drop because they need to be 101 - ``drop`` 102 - Traps packets that the device decided to drop because they need to be
|
| /Documentation/usb/ |
| D | text_files.rst | 13 USB devfs drop permissions source 16 .. literalinclude:: usbdevfs-drop-permissions.c
|
| /Documentation/devicetree/bindings/sound/ |
| D | st,sta350.txt | 51 - "drop-compensation" 54 - "variable-drop-compensation" (default) 56 - st,drop-compensation-ns: number 58 "variable-drop-compensation". 59 Specifies the drop compensation in nanoseconds.
|
| D | st,sta32x.txt | 55 - st,drop-compensation-ns: number 57 "variable-drop-compensation". 58 Specifies the drop compensation in nanoseconds.
|
| /Documentation/hwmon/ |
| D | ina2xx.rst | 62 interface. The INA219 monitors both shunt drop and supply voltage, with 66 interface. The INA220 monitors both shunt drop and supply voltage. 69 The INA226 monitors both a shunt voltage drop and bus supply voltage. 72 with an I2C interface. The chips monitor both a shunt voltage drop and
|
| /Documentation/networking/ |
| D | ipvs-sysctl.rst | 13 It sets the always mode drop rate, which is used in the mode 3 83 - 4 - drop entry 103 The drop_entry defense is to randomly drop entries in the 121 The drop_packet defense is designed to drop 1/rate packets 123 drop all the incoming packets. 129 threshold. When the mode 3 is set, the always mode drop rate 156 The default value is 0, the load balancer will silently drop
|
| D | seg6-sysctl.rst | 12 Accept or drop SR-enabled IPv6 packets on this interface. 24 * 1 - Drop SR packets without HMAC, validate SR packets with HMAC
|
| D | filter.rst | 46 setup a socket, attach a filter, lock it then drop privileges and be 317 jne #0x806, drop 319 drop: ret #0 324 jne #0x800, drop 326 jneq #6, drop 328 drop: ret #0 333 jne #0x800, drop 335 jneq #1, drop 339 jneq #1, drop 341 drop: ret #0 [all …]
|
| D | tc-actions-env-rules.rst | 21 TC_ACT_SHOT to the caller and they will drop it.
|
| /Documentation/devicetree/bindings/rtc/ |
| D | abracon,abx80x.yaml | 41 Supported are 'standard' diodes with a 0.6V drop 42 and 'schottky' diodes with a 0.3V drop.
|
| /Documentation/admin-guide/blockdev/drbd/ |
| D | index.rst | 10 clusters and in this context, is a "drop-in" replacement for shared
|
| /Documentation/netlink/specs/ |
| D | tcp_metrics.yaml | 60 name: fopen-syn-drop-ts 155 - fopen-syn-drop-ts
|
| D | netdev.yaml | 343 Allocation failure may, or may not result in a packet drop, depending 355 name: rx-hw-drop-overruns 400 name: rx-hw-drop-ratelimits 414 name: tx-hw-drop-errors 449 name: tx-hw-drop-ratelimits
|
| D | tc.yaml | 557 name: prob-drop 561 name: forced-drop 728 doc: Drops due to drop() calls 758 name: drop-next 760 doc: Time to drop next packet 762 name: drop-overlimit 789 name: drop-overlimit 817 name: drop-overmemory 931 name: drop-overlimit 1001 doc: Drops due to drop() calls [all …]
|
| /Documentation/networking/device_drivers/ethernet/freescale/dpaa2/ |
| D | switch-driver.rst | 127 Routing actions (redirect, trap, drop) 146 * drop 159 Example 2: drop frames received on eth4 with VID 100 and PCP of 3:: 161 …$ tc filter add dev eth4 ingress protocol 802.1q flower skip_sw vlan_id 100 vlan_prio 3 action drop
|
| /Documentation/filesystems/ |
| D | path-lookup.txt | 285 requires ref-walk, then instead of restarting the walk, we attempt to drop rcu 311 * When the destination dentry is reached, drop rcu there (ie. take d_lock, 342 drop rcu that fail due to d_seq failure and requiring the entire path lookup 345 routine requiring rcu drop, permission for permission check requiring drop, 346 and link for symlink traversal requiring drop. 363 condition that can't be resolved in rcu-walk mode. Ideally, we drop rcu-walk 367 Note that a graceful drop from rcu-walk mode due to something such as the
|
| /Documentation/devicetree/bindings/net/ |
| D | ti,dp83822.yaml | 34 Sets the DP83822 to detect a link drop condition when the signal goes 35 high. If not set then link drop will occur when the signal goes low.
|
| D | fsl,enetc.yaml | 12 (SR-IOV), advanced QoS with 8 traffic classes and 4 drop resilience levels,
|
| /Documentation/devicetree/bindings/regulator/ |
| D | richtek,rt4831-regulator.yaml | 22 voltage drop from the heavy loading scenario. But it also make the power
|
| /Documentation/admin-guide/cgroup-v1/ |
| D | net_cls.rst | 44 iptables -A OUTPUT -m cgroup ! --cgroup 0x100001 -j DROP
|
| /Documentation/ABI/testing/ |
| D | sysfs-memory-page-offline | 32 trying to drop the page or killing any owner or
|
| /Documentation/power/ |
| D | charger-manager.rst | 135 battery voltage drop fullbatt_vchkdrop_ms after the battery is fully 136 charged. If the voltage drop is over fullbatt_vchkdrop_uV, Charger 138 chargers. Recharge with voltage drop condition only (without delay
|
| /Documentation/devicetree/bindings/iio/dac/ |
| D | microchip,mcp4725.yaml | 37 capability not to drop its voltage when connected to the internal
|
1234567