Home
last modified time | relevance | path

Searched full:duplex (Results 1 – 25 of 94) sorted by relevance

1234

/Documentation/networking/device_drivers/ethernet/3com/
D3c509.rst29 - 3c509B (later revision of the ISA card; supports full-duplex)
31 - 3c589B (later revision of the 3c589; supports full-duplex)
47 needed except to enable full-duplex mode (see below). An example of the syntax
62 Full-duplex mode
65 The v1.18c driver added support for the 3c509B's full-duplex capabilities.
66 In order to enable and successfully use full-duplex mode, three conditions
70 duplex operations. Currently, the only members of the 3c509 family that are
71 positively known to support full-duplex are the 3c509B (ISA bus) and 3c589B
73 full-duplex mode; these include the original 3c509 (no "B"), the original
78 AUI and 10base2 network cabling is physically incapable of full-duplex
[all …]
Dvortex.rst128 0x0200 Force full duplex mode.
136 will force full-duplex 100base-TX, rather than allowing the usual
148 full-duplex mode. Please use this in preference to the ``options``
156 Sets full duplex mode for all 3c59x NICs in the machine. Entries
166 full duplex mode.
276 the same network being in full-duplex mode, while this host is in
277 half-duplex mode. You need to find that other host and make it run in
278 half-duplex mode or fix this host to run in full-duplex mode.
280 As a last resort, you can force the 3c59x driver into full-duplex mode
347 100" and "duplex full" as well (or "speed 10" and "duplex half").
[all …]
/Documentation/networking/device_drivers/ethernet/ti/
Dtlan.rst81 3. You can set duplex=1 to force half duplex, and duplex=2 to
82 force full duplex.
89 5. You have to use speed=X duplex=Y together now. If you just
91 To force a 10Mbps Half-Duplex link do "insmod tlan.o speed=10
92 duplex=1".
107 0x02 use half duplex
108 0x04 use full duplex
113 You also need to set both speed and duplex settings when forcing
115 ether=0,0,0x12,0,eth0 will force link to 100Mbps Half-Duplex.
121 insmod tlan speed=0,100 duplex=0,1
[all …]
/Documentation/networking/device_drivers/ethernet/intel/
De1000.rst15 - Speed and Duplex Configuration
40 For more information about the AutoNeg, Duplex, and Speed
41 parameters, see the "Speed and Duplex Configuration" section in
57 This parameter is a bit-mask that specifies the speed and duplex settings
59 Duplex parameters must not be specified.
62 Refer to the Speed and Duplex section of this readme for more
65 Duplex section in Command Line Parameters
74 either one or two-directional. If both Duplex and the link partner are
75 set to auto-negotiate, the board auto-detects the correct duplex. If the
76 link partner is forced (either full or half), Duplex defaults to half-
[all …]
De100.rst76 Speed/Duplex:
77 The driver auto-negotiates the link speed and duplex settings by
78 default. The ethtool utility can be used as follows to force speed/duplex.::
80 ethtool -s eth? autoneg off speed {10|100} duplex {full|half}
82 NOTE: setting the speed/duplex to incorrect values will cause the link to
/Documentation/devicetree/bindings/phy/
Dmscc,vsc7514-serdes.yaml23 half/full-duplex and 1000Mbps in full-duplex mode while SERDES6G supports
24 10/100Mbps in half/full-duplex and 1000/2500Mbps in full-duplex mode.
/Documentation/networking/device_drivers/ethernet/dlink/
Ddl2k.rst215 10mbps_hd 10Mbps half duplex.
216 10mbps_fd 10Mbps full duplex.
217 100mbps_hd 100Mbps half duplex.
218 100mbps_fd 100Mbps full duplex.
219 1000mbps_fd 1000Mbps full duplex.
220 1000mbps_hd 1000Mbps half duplex.
222 1 10Mbps half duplex.
223 2 10Mbps full duplex.
224 3 100Mbps half duplex.
225 4 100Mbps full duplex.
[all …]
/Documentation/spi/
Dspidev.rst5 SPI devices have a limited userspace API, supporting basic half-duplex
7 full duplex transfers and device I/O configuration are also available.
112 Standard read() and write() operations are obviously only half-duplex, and
113 the chipselect is deactivated between those operations. Full-duplex access,
174 FULL DUPLEX CHARACTER DEVICE API
178 full duplex programming interface. (Although it doesn't perform a full duplex
183 The example shows one half-duplex RPC-style request and response message.
190 To make a full duplex request, provide both rx_buf and tx_buf for the
/Documentation/devicetree/bindings/spi/
Darm,pl022-peripheral-props.yaml21 - 2 # Microwire (Half Duplex)
55 pl022,duplex:
56 description: Microwire interface - Full/Half duplex
Dicpdas-lp8841-spi-rtc.txt6 The device uses the standard MicroWire half-duplex transfer timing.
29 full duplex mode.
Dst,stm32-spi.yaml11 the Serial Peripheral Interface. It supports full-duplex, half-duplex and
/Documentation/networking/device_drivers/ethernet/dec/
Ddmfe.rst35 insmod dmfe mode=0 # Force 10M Half Duplex
36 insmod dmfe mode=1 # Force 100M Half Duplex
37 insmod dmfe mode=4 # Force 10M Full Duplex
38 insmod dmfe mode=5 # Force 100M Full Duplex
/Documentation/devicetree/bindings/net/
Dethernet-controller.yaml178 Duplex configuration. 0 for half duplex or 1 for
179 full duplex
202 full-duplex:
205 Indicates that full-duplex is used. When absent, half
206 duplex is assumed.
Dactions,owl-emac.yaml15 IEEE 802.3 CSMA/CD standard, supporting both half-duplex and full-duplex
Dloongson,ls1c-emac.yaml18 - Full-duplex operation (IEEE 802.3x flow control automatic transmission)
19 - Half-duplex operation (CSMA/CD Protocol and back-pressure support)
Dloongson,ls1b-gmac.yaml18 - Full-duplex operation (IEEE 802.3x flow control automatic transmission)
19 - Half-duplex operation (CSMA/CD Protocol and back-pressure support)
/Documentation/devicetree/bindings/net/dsa/
Dmicrochip,lan937x.yaml78 full-duplex;
132 full-duplex;
145 full-duplex;
Dmscc,ocelot.yaml145 full-duplex;
157 full-duplex;
242 full-duplex;
254 full-duplex;
Dbrcm,b53.yaml170 full-duplex;
180 full-duplex;
263 full-duplex;
Dmicrochip,ksz.yaml131 full-duplex;
180 full-duplex;
218 full-duplex;
Dmediatek,mt7530.yaml357 full-duplex;
420 full-duplex;
484 full-duplex;
550 full-duplex;
638 full-duplex;
726 full-duplex;
813 full-duplex;
/Documentation/devicetree/bindings/serial/
Drs485.yaml10 direction for the built-in half-duplex mode. The properties described
11 hereafter shall be given to a half-duplex capable UART node.
/Documentation/ABI/testing/
Dsysfs-class-led-trigger-netdev173 Signal the link half duplex state of the named network device.
178 duplex state of the named network device.
186 Signal the link full duplex state of the named network device.
191 duplex state of the named network device.
/Documentation/driver-api/
Dspi.rst9 duplex protocol; for each bit shifted out the MOSI line (one per clock)
42 which wraps a full duplex SPI transfer. A variety of protocol tweaking
/Documentation/driver-api/serial/
Dserial-rs485.rst19 half-duplex mode capable of automatically controlling line direction by
21 half-duplex hardware like an RS485 transceiver or any RS232-connected
22 half-duplex devices like some modems.

1234