Home
last modified time | relevance | path

Searched full:monitors (Results 1 – 25 of 85) sorted by relevance

1234

/Documentation/trace/rv/
Druntime-verification.rst23 Runtime Monitors and Reactors
30 In Linux terms, the runtime verification monitors are encapsulated inside the
59 In Linux terms, a *reactor* is an reaction method available for *RV monitors*.
60 By default, all monitors should provide a trace output of their actions,
77 Online RV monitors
80 Monitors can be classified as *offline* and *online* monitors. *Offline*
82 reading the trace execution from a permanent storage system. *Online* monitors
83 process the trace during the execution of the system. Online monitors are said
87 of monitor has a set of advantages. For example, *offline* monitors can be
92 Another important aspect regarding monitors is the overhead associated with the
[all …]
/Documentation/tools/rv/
Drv-mon.rst7 List available monitors
22 monitors.
31 AVAILABLE MONITORS
34 The **rv** tool provides the interface for a set of monitors. Use the
35 **rv list** command to list all available monitors.
Drv-list.rst7 List available monitors
20 The **rv list** command prints all available monitors. These monitors
Drv.rst28 verification (rv) monitors.
35 List all available monitors.
Dindex.rst8 (rv) monitors.
/Documentation/arch/arm64/
Damu.rst4 Activity Monitors Unit (AMU) extension in AArch64 Linux
11 This document briefly describes the provision of Activity Monitors Unit
18 The activity monitors extension is an optional extension introduced by the
21 The activity monitors unit, implemented in each CPU, provides performance
26 Version 1 of the Activity Monitors architecture implements a counter group
39 The Activity Monitors architecture provides space for up to 16 architected
53 activity monitors extension. Therefore, when CONFIG_ARM64_AMU_EXTN is
/Documentation/hwmon/
Dmax16065.rst59 The MAX16067 flash-configurable system manager monitors and sequences multiple
62 The MAX16068 flash-configurable system manager monitors and manages up to six
65 The MAX16070/MAX16071 flash-configurable system monitors supervise multiple
68 MAX16070 monitors up to twelve system voltages simultaneously, and the MAX16071
69 monitors up to eight supply voltages.
Dadm1031.rst42 The ADM1030 monitors a single fan speed, while the ADM1031 monitors up to
Dina2xx.rst62 interface. The INA219 monitors both shunt drop and supply voltage, with
66 interface. The INA220 monitors both shunt drop and supply voltage.
69 The INA226 monitors both a shunt voltage drop and bus supply voltage.
71 INA230 and INA231 are high or low side current shunt and power monitors
Dtmp513.rst28 The TMP512 (dual-channel) and TMP513 (triple-channel) are system monitors
30 shunt monitor. These system monitors have the capability of measuring remote
Dina3221.rst21 The Texas Instruments INA3221 monitors voltage, current, and power on the high
22 side of up to three D.C. power supplies. The INA3221 monitors both shunt drop
Dadm1177.rst16 Hot-Swap Controller and Digital Power Monitors with Soft Start Pin.
Dmc34vr500.rst20 monitors the temperature, input voltage and output currents and provides
/Documentation/devicetree/bindings/iio/adc/
Dmicrochip,pac1934.yaml7 title: Microchip PAC1934 Power Monitors with Accumulator
13 This device is part of the Microchip family of Power Monitors with
Dmaxim,max34408.yaml7 title: Maxim MAX34408/MAX34409 current monitors with overcurrent control
13 The MAX34408/MAX34409 are two- and four-channel current monitors that are
/Documentation/devicetree/bindings/hwmon/
Dti,tmp513.yaml14 The TMP512 (dual-channel) and TMP513 (triple-channel) are system monitors
16 current shunt monitor. These system monitors have the capability of measuring
Dadi,adm1275.yaml8 title: Analog Devices ADM1075/ADM127x/ADM1281/ADM129x digital power monitors
14 The ADM1293 and ADM1294 are high accuracy integrated digital power monitors
Dlltc,ltc4286.yaml7 title: LTC4286 power monitors
/Documentation/accounting/
Dpsi.rst97 Monitors activate only when system enters stall state for the monitored
105 after which monitors are most likely not needed and psi averages can be used
108 Unprivileged users can also create monitors, with the only limitation that the
187 Per-cgroup psi monitors can be specified and used the same way as
/Documentation/devicetree/bindings/perf/
Darm,ni.yaml7 title: Arm NI (Network-on-Chip Interconnect) Performance Monitors
Darm,ccn.yaml7 title: ARM CCN (Cache Coherent Network) Performance Monitors
/Documentation/devicetree/bindings/powerpc/fsl/
Ddiu.txt4 drive DVI monitors.
/Documentation/devicetree/bindings/display/
Dsm501fb.txt4 drive DVI monitors.
/Documentation/devicetree/bindings/hwmon/pmbus/
Dadi,adp1050.yaml15 and has four individual monitors for input/output voltage, input current
/Documentation/devicetree/bindings/arm/freescale/
Dfsl,imx7ulp-pm.yaml15 monitors events to trigger transitions between power modes while

1234