At present, the following scanners are known to work with this backend:
Model: Connection Type --------------------------- ------------------- LS-30 (Coolscan III) SCSI LS-2000 SCSI LS-40 ED (Coolscan IV) USB LS-4000 ED IEEE 1394 LS-8000 ED IEEE 1394
scanimage --help -d coolscan2:<interface>:<device>
where <interface> and <device> specify the device in question, as in the configuration file (see next section). The -d parameter and its argument can be omitted to obtain information on the first scanner identified. Use the command:
scanimage -L
to list all devices recognized by your SANE installation. The options should be fully described by the description or tooltips given by frontend. Here is a description of some of the most important options, in the syntax with which they must be supplied to scanimage (1):
--frame <n> This option specifies which frame to operate on, if a motorized film strip feeder or APS adapter are used. The frame number <n> ranges from 1 to the number of frames available, which is sensed each time the backend is initialized (usually each time you start the frontend).
--subframe <x> This option shifts the scan window by the specified amount (default unit is mm).
--infrared=yes/no If set to "yes", the scanner will read the infrared channel, thus allowing defect removal in software. The infrared image is read during a second scan, with no options altered. The backend must not be restarted between the scans. If you use scanimage (1), perform a batch scan with --batch-count=2 to obtain the IR information.
--depth <n> Here <n> can either be 8 or the maximum number of bits supported by the scanner (10, 12, or 14). It specifies whether or not the scanner reduces the scanned data to 8 bits before sending it to the backend. If 8 bits are used, some information and thus image quality is lost, but the amount of data is smaller compared to higher depths. Also, many imaging programs and image formats cannot handle depths greater than 8 bits.
--autofocus Perform autofocus operation. Unless otherwise specified by the other options ( --focus-on-centre and friends), focusing is performed on the centre of the selected scan area.
--ae-wb
--ae Perform a pre-scan to calculate exposure values automatically. --ae-wb will maintain the white balance, while --ae will adjust each channel separately.
--exposure Multiply all exposure times with this value. This allows exposure correction without modifying white balance.
--load Load the next slide when using the slide loader (applies only to the SF-200 bulk feeder).
--eject Eject the film strip or mounted slide when using the slide loader.
--reset Reset scanner. The scanner will perform the same action as when power is turned on: it will eject the film strip (with the SF-200 bulk feeder) and calibrate itself. Use this whenever the scanner refuses to load a film strip properly, as a result of which --eject does not work.
blank or starting with a '#' character These lines are ignored, thus '#' can be used to include comments.
containing only the word """auto""" This instructs the backend to probe for a scanner by scanning the buses for devices with known identifiers. This is the default action when no configuration file is present.
a line of the form <interface>:<device> Here <interface> can be one of "scsi" or "usb", and <device> is the device file of the scanner. Note that IEEE 1394 devices are handled by the SBP-2 module in the kernel and appear to SANE as SCSI devices.
@LIBDIR@/libsane-coolscan2.a The static library implementing this backend.
@LIBDIR@/libsane-coolscan2.so The shared library implementing this backend (present on systems that support dynamic loading).
@CONFIGDIR@/coolscan2.conf Configuration file for this backend, read each time the backend is initialized.
SANE_DEBUG_COOLSCAN2 If the library was compiled with debug support enabled, this environment variable controls the debug level for this backend. E.g., a value of 128 requests all debug output to be printed. Smaller levels reduce verbosity.