• Home
  • Line#
  • Scopes#
  • Navigate#
  • Raw
  • Download
1# For documentation see sane-umax_pp(5)
2
3# GLOBAL #
4
5# size (in bytes) of scan buffer (default: 2 megabyte)
6option buffer 1048576
7
8
9# DEVICES #
10
11# specify the port your scanner is connected to.
12#
13# the value 'auto' will make the backend find the correct value
14# by itself, it will scan  ppdev, ppi device, then hardware address
15# 'safe-auto' will do the same but won't do direct hardware access
16# on linux systems, you may provide the device name of the ppdev character
17# device : /dev/parport0, /dev/parport1, ......
18#
19# on *BSD, you may provide the device name of the ppi device: /dev/ppi0,
20# /dev/ppi1, ...
21#
22# Possible hardware addresses are 0x378 (lp0)
23# 0x278 (lp2) and 0x3c8 (lp1)
24#
25
26port safe-auto
27
28# the following options are local to this scanner
29# gain for red channel, if not given, will be automatically computed
30# must be between 0 and 15
31option red-gain 1
32
33# gain for green channel, if not given, will be automatically computed
34# must be between 0 and 15
35option green-gain 2
36
37# gain for blue channel, if not given, will be automatically computed
38# must be between 0 and 15
39option blue-gain 3
40
41# offset for red channel, if not given, will default to 0
42# must be between 0 and 15
43option red-offset 4
44
45# offset for green channel, if not given, will default to 0
46# must be between 0 and 15
47option green-offset 5
48
49# offset for blue channel, if not given, will default to 0
50# must be between 0 and 15
51option blue-offset 6
52
53
54#
55#
56# model number
57#
58# valid values are 610, 1220, 1600 and 2000
59#
60# by default, no model, we rely on autodetection
61# in case you have black or 'inverted' scans,
62# you may override detection by providing the
63# model number
64option astra 1600
65