1/* SPDX-License-Identifier: GPL-2.0-only */
2
3/* Global Variables */
4
5Field (GNVS, ByteAcc, NoLock, Preserve)
6{
7	/* Miscellaneous */
8	,	16,	// 0x00 - Operating System
9	SMIF,	 8,	// 0x02 - SMI function
10	,	 8,	// 0x03 - SMI function parameter
11	,	 8,	// 0x04 - SMI function parameter
12	SCIF,	 8,	// 0x05 - SCI function
13	,	 8,	// 0x06 - SCI function parameter
14	,	 8,	// 0x07 - SCI function parameter
15	,	 8,	// 0x08 - Global Lock function for EC
16	,	 8,	// 0x09 - Lock function parameter
17	,	 8,	// 0x0a - Lock function parameter
18	P80D,	32,	// 0x0b - Debug port (IO 0x80) value
19	LIDS,	 8,	// 0x0f - LID state (open = 1)
20	,	 8,	// 0x10 - Power State (AC = 1)
21	/* Thermal policy */
22	Offset (0x11),
23	TLVL,    8,	// 0x11 - Throttle Level Limit
24	FLVL,	 8,	// 0x12 - Current FAN Level
25	TCRT,    8,	// 0x13 - Critical Threshold
26	TPSV,	 8,	// 0x14 - Passive Threshold
27	TMAX,	 8,	// 0x15 - CPU Tj_max
28	F0OF,	 8,	// 0x16 - FAN 0 OFF Threshold
29	F0ON,	 8,	// 0x17 - FAN 0 ON Threshold
30	F0PW,	 8,	// 0x18 - FAN 0 PWM value
31	F1OF,	 8,	// 0x19 - FAN 1 OFF Threshold
32	F1ON,	 8,	// 0x1a - FAN 1 ON Threshold
33	F1PW,	 8,	// 0x1b - FAN 1 PWM value
34	F2OF,	 8,	// 0x1c - FAN 2 OFF Threshold
35	F2ON,	 8,	// 0x1d - FAN 2 ON Threshold
36	F2PW,	 8,	// 0x1e - FAN 2 PWM value
37	F3OF,	 8,	// 0x1f - FAN 3 OFF Threshold
38	F3ON,	 8,	// 0x20 - FAN 3 ON Threshold
39	F3PW,	 8,	// 0x21 - FAN 3 PWM value
40	F4OF,	 8,	// 0x22 - FAN 4 OFF Threshold
41	F4ON,	 8,	// 0x23 - FAN 4 ON Threshold
42	F4PW,	 8,	// 0x24 - FAN 4 PWM value
43	TMPS,    8,	// 0x25 - Temperature Sensor ID
44	/* Processor Identification */
45	Offset (0x28),
46	,	 8,	// 0x28 -  Enabled by coreboot
47	,	 8,	// 0x29 - Multi Processor Enable
48	PCP0,	 8,	// 0x2a - PDC CPU/CORE 0
49	PCP1,	 8,	// 0x2b - PDC CPU/CORE 1
50	PPCM,	 8,	// 0x2c - Max. PPC state
51	,	 8,	// 0x2d - Processor count
52	/* Super I/O & CMOS config */
53	Offset (0x32),
54	NATP,	 8,	// 0x32 -
55	S5U0,	 8,	// 0x33 - Enable USB0 in S5
56	S5U1,	 8,	// 0x34 - Enable USB1 in S5
57	S3U0,	 8,	// 0x35 - Enable USB0 in S3
58	S3U1,	 8,	// 0x36 - Enable USB1 in S3
59	S33G,	 8,	// 0x37 - Enable 3G in S3
60	,	 32,	// 0x38 - CBMEM TOC
61	/* Integrated Graphics Device */
62	Offset (0x3c),
63	IGDS,	 8,	// 0x3c - IGD state (primary = 1)
64	TLST,	 8,	// 0x3d - Display Toggle List pointer
65	CADL,	 8,	// 0x3e - Currently Attached Devices List
66	PADL,	 8,	// 0x3f - Previously Attached Devices List
67	/* Backlight Control */
68	Offset (0x64),
69	BLCS,	 8,	// 0x64 - Backlight control possible?
70	BRTL,	 8,	// 0x65 - Brightness Level
71	ODDS,	 8,	// 0x66
72	/* Ambient Light Sensors */
73	Offset (0x6e),
74	ALSE,	 8,	// 0x6e - ALS enable
75	ALAF,	 8,	// 0x6f - Ambient light adjustment factor
76	LLOW,	 8,	// 0x70 - LUX Low
77	LHIH,	 8,	// 0x71 - LUX High
78	/* EMA */
79	Offset (0x78),
80	EMAE,	 8,	// 0x78 - EMA enable
81	EMAP,	16,	// 0x79 - EMA pointer
82	EMAL,	16,	// 0x7b - EMA length
83	/* MEF */
84	Offset (0x82),
85	MEFE,	 8,	// 0x82 - MEF enable
86	/* TPM support */
87	Offset (0x8c),
88	TPMP,	 8,	// 0x8c - TPM
89	TPME,	 8,	// 0x8d - TPM enable
90	/* SATA */
91	Offset (0x96),
92	GTF0,	56,	// 0x96 - GTF task file buffer for port 0
93	GTF1,	56,	// 0x9d - GTF task file buffer for port 1
94	GTF2,	56,	// 0xa4 - GTF task file buffer for port 2
95	IDEM,	 8,	// 0xab - IDE mode (compatible / enhanced)
96	IDET,	 8,	// 0xac - IDE
97	/* XHCI */
98	Offset (0xb2),
99	XHCI,	 8,
100
101	PM1I,	32,	// System Wake Source - PM1 Index
102	GPEI,	32,	// GPE Wake Source
103
104	Offset (0xf5),
105	TPIQ,	 8,	// 0xf5 - trackpad IRQ value
106	,	32,
107}
108
109External (\_TZ.SKIN)
110
111Method (TZUP)
112{
113#ifdef HAVE_THERMALZONE
114	/* Update Primary Thermal Zone */
115	If (CondRefOf (\_TZ.THRM)) {
116		Notify (\_TZ.THRM, 0x81)
117	}
118#endif
119
120	/* Update Secondary Thermal Zone */
121	If (CondRefOf (\_TZ.SKIN)) {
122		Notify (\_TZ.SKIN, 0x81)
123	}
124}
125
126/* Update Fan 0 thresholds */
127Method (F0UT, 2)
128{
129	\F0OF = Arg0
130	\F0ON = Arg1
131	TZUP ()
132}
133
134/* Update Fan 1 thresholds */
135Method (F1UT, 2)
136{
137	\F1OF = Arg0
138	\F1ON = Arg1
139	TZUP ()
140}
141
142/* Update Fan 2 thresholds */
143Method (F2UT, 2)
144{
145	\F2OF = Arg0
146	\F2ON = Arg1
147	TZUP ()
148}
149
150/* Update Fan 3 thresholds */
151Method (F3UT, 2)
152{
153	\F3OF = Arg0
154	\F3ON = Arg1
155	TZUP ()
156}
157
158/* Update Fan 4 thresholds */
159Method (F4UT, 2)
160{
161	\F4OF = Arg0
162	\F4ON = Arg1
163	TZUP ()
164}
165
166/* Update Temperature Sensor ID */