1Kernel driver max34440
2======================
3
4Supported chips:
5  * Maxim MAX34440
6    Prefixes: 'max34440'
7    Addresses scanned: -
8    Datasheet: http://datasheets.maxim-ic.com/en/ds/MAX34440.pdf
9  * Maxim MAX34441
10    PMBus 5-Channel Power-Supply Manager and Intelligent Fan Controller
11    Prefixes: 'max34441'
12    Addresses scanned: -
13    Datasheet: http://datasheets.maxim-ic.com/en/ds/MAX34441.pdf
14  * Maxim MAX34446
15    PMBus Power-Supply Data Logger
16    Prefixes: 'max34446'
17    Addresses scanned: -
18    Datasheet: http://datasheets.maxim-ic.com/en/ds/MAX34446.pdf
19
20Author: Guenter Roeck <guenter.roeck@ericsson.com>
21
22
23Description
24-----------
25
26This driver supports hardware montoring for Maxim MAX34440 PMBus 6-Channel
27Power-Supply Manager, MAX34441 PMBus 5-Channel Power-Supply Manager
28and Intelligent Fan Controller, and MAX34446 PMBus Power-Supply Data Logger.
29
30The driver is a client driver to the core PMBus driver. Please see
31Documentation/hwmon/pmbus for details on PMBus client drivers.
32
33
34Usage Notes
35-----------
36
37This driver does not auto-detect devices. You will have to instantiate the
38devices explicitly. Please see Documentation/i2c/instantiating-devices for
39details.
40
41For MAX34446, the value of the currX_crit attribute determines if current or
42voltage measurement is enabled for a given channel. Voltage measurement is
43enabled if currX_crit is set to 0; current measurement is enabled if the
44attribute is set to a positive value. Power measurement is only enabled if
45channel 1 (3) is configured for voltage measurement, and channel 2 (4) is
46configured for current measurement.
47
48
49Platform data support
50---------------------
51
52The driver supports standard PMBus driver platform data.
53
54
55Sysfs entries
56-------------
57
58The following attributes are supported. Limits are read-write; all other
59attributes are read-only.
60
61in[1-6]_label		"vout[1-6]".
62in[1-6]_input		Measured voltage. From READ_VOUT register.
63in[1-6]_min		Minimum Voltage. From VOUT_UV_WARN_LIMIT register.
64in[1-6]_max		Maximum voltage. From VOUT_OV_WARN_LIMIT register.
65in[1-6]_lcrit		Critical minimum Voltage. VOUT_UV_FAULT_LIMIT register.
66in[1-6]_crit		Critical maximum voltage. From VOUT_OV_FAULT_LIMIT register.
67in[1-6]_min_alarm	Voltage low alarm. From VOLTAGE_UV_WARNING status.
68in[1-6]_max_alarm	Voltage high alarm. From VOLTAGE_OV_WARNING status.
69in[1-6]_lcrit_alarm	Voltage critical low alarm. From VOLTAGE_UV_FAULT status.
70in[1-6]_crit_alarm	Voltage critical high alarm. From VOLTAGE_OV_FAULT status.
71in[1-6]_lowest		Historical minimum voltage.
72in[1-6]_highest		Historical maximum voltage.
73in[1-6]_reset_history	Write any value to reset history.
74
75			MAX34446 only supports in[1-4].
76
77curr[1-6]_label		"iout[1-6]".
78curr[1-6]_input		Measured current. From READ_IOUT register.
79curr[1-6]_max		Maximum current. From IOUT_OC_WARN_LIMIT register.
80curr[1-6]_crit		Critical maximum current. From IOUT_OC_FAULT_LIMIT register.
81curr[1-6]_max_alarm	Current high alarm. From IOUT_OC_WARNING status.
82curr[1-6]_crit_alarm	Current critical high alarm. From IOUT_OC_FAULT status.
83curr[1-4]_average	Historical average current (MAX34446 only).
84curr[1-6]_highest	Historical maximum current.
85curr[1-6]_reset_history	Write any value to reset history.
86
87			in6 and curr6 attributes only exist for MAX34440.
88			MAX34446 only supports curr[1-4].
89
90power[1,3]_label	"pout[1,3]"
91power[1,3]_input	Measured power.
92power[1,3]_average	Historical average power.
93power[1,3]_highest	Historical maximum power.
94
95			Power attributes only exist for MAX34446.
96
97temp[1-8]_input		Measured temperatures. From READ_TEMPERATURE_1 register.
98			temp1 is the chip's internal temperature. temp2..temp5
99			are remote I2C temperature sensors. For MAX34441, temp6
100			is a remote thermal-diode sensor. For MAX34440, temp6..8
101			are remote I2C temperature sensors.
102temp[1-8]_max		Maximum temperature. From OT_WARN_LIMIT register.
103temp[1-8]_crit		Critical high temperature. From OT_FAULT_LIMIT register.
104temp[1-8]_max_alarm	Temperature high alarm.
105temp[1-8]_crit_alarm	Temperature critical high alarm.
106temp[1-8]_average	Historical average temperature (MAX34446 only).
107temp[1-8]_highest	Historical maximum temperature.
108temp[1-8]_reset_history	Write any value to reset history.
109
110			temp7 and temp8 attributes only exist for MAX34440.
111			MAX34446 only supports temp[1-3].
112