• Home
  • Line#
  • Scopes#
  • Navigate#
  • Raw
  • Download
1 /*
2  * arch/arm/mach-u300/regulator.c
3  *
4  * Copyright (C) 2009 ST-Ericsson AB
5  * License terms: GNU General Public License (GPL) version 2
6  * Handle board-bound regulators and board power not related
7  * to any devices.
8  * Author: Linus Walleij <linus.walleij@stericsson.com>
9  */
10 #include <linux/device.h>
11 #include <linux/signal.h>
12 #include <linux/err.h>
13 #include <linux/regulator/consumer.h>
14 /* Those are just for writing in syscon */
15 #include <linux/io.h>
16 #include <mach/hardware.h>
17 #include <mach/syscon.h>
18 
19 /*
20  * Regulators that power the board and chip and which are
21  * not copuled to specific drivers are hogged in these
22  * instances.
23  */
24 static struct regulator *main_power_15;
25 
26 /*
27  * This function is used from pm.h to shut down the system by
28  * resetting all regulators in turn and then disable regulator
29  * LDO D (main power).
30  */
u300_pm_poweroff(void)31 void u300_pm_poweroff(void)
32 {
33 	sigset_t old, all;
34 
35 	sigfillset(&all);
36 	if (!sigprocmask(SIG_BLOCK, &all, &old)) {
37 		/* Disable LDO D to shut down the system */
38 		if (main_power_15)
39 			regulator_disable(main_power_15);
40 		else
41 			pr_err("regulator not available to shut down system\n");
42 		(void) sigprocmask(SIG_SETMASK, &old, NULL);
43 	}
44 	return;
45 }
46 
47 /*
48  * Hog the regulators needed to power up the board.
49  */
u300_init_boardpower(void)50 static int __init u300_init_boardpower(void)
51 {
52 	int err;
53 	u32 val;
54 
55 	pr_info("U300: setting up board power\n");
56 	main_power_15 = regulator_get(NULL, "vana15");
57 	if (IS_ERR(main_power_15)) {
58 		pr_err("could not get vana15");
59 		return PTR_ERR(main_power_15);
60 	}
61 	err = regulator_enable(main_power_15);
62 	if (err) {
63 		pr_err("could not enable vana15\n");
64 		return err;
65 	}
66 
67 	/*
68 	 * On U300 a special system controller register pulls up the DC
69 	 * until the vana15 (LDO D) regulator comes up. At this point, all
70 	 * regulators are set and we do not need power control via
71 	 * DC ON anymore. This function will likely be moved whenever
72 	 * the rest of the U300 power management is implemented.
73 	 */
74 	pr_info("U300: disable system controller pull-up\n");
75 	val = readw(U300_SYSCON_VBASE + U300_SYSCON_PMCR);
76 	val &= ~U300_SYSCON_PMCR_DCON_ENABLE;
77 	writew(val, U300_SYSCON_VBASE + U300_SYSCON_PMCR);
78 
79 	/* Register globally exported PM poweroff hook */
80 	pm_power_off = u300_pm_poweroff;
81 
82 	return 0;
83 }
84 
85 /*
86  * So at module init time we hog the regulator!
87  */
88 module_init(u300_init_boardpower);
89