• Home
  • Line#
  • Scopes#
  • Navigate#
  • Raw
  • Download
1 /*
2  * nvec_power: power supply driver for a NVIDIA compliant embedded controller
3  *
4  * Copyright (C) 2011 The AC100 Kernel Team <ac100@lists.launchpad.net>
5  *
6  * Authors:  Ilya Petrov <ilya.muromec@gmail.com>
7  *           Marc Dietrich <marvin24@gmx.de>
8  *
9  * This file is subject to the terms and conditions of the GNU General Public
10  * License.  See the file "COPYING" in the main directory of this archive
11  * for more details.
12  *
13  */
14 
15 #include <linux/module.h>
16 #include <linux/platform_device.h>
17 #include <linux/err.h>
18 #include <linux/power_supply.h>
19 #include <linux/slab.h>
20 #include <linux/workqueue.h>
21 #include <linux/delay.h>
22 
23 #include "nvec.h"
24 
25 struct nvec_power {
26 	struct notifier_block notifier;
27 	struct delayed_work poller;
28 	struct nvec_chip *nvec;
29 	int on;
30 	int bat_present;
31 	int bat_status;
32 	int bat_voltage_now;
33 	int bat_current_now;
34 	int bat_current_avg;
35 	int time_remain;
36 	int charge_full_design;
37 	int charge_last_full;
38 	int critical_capacity;
39 	int capacity_remain;
40 	int bat_temperature;
41 	int bat_cap;
42 	int bat_type_enum;
43 	char bat_manu[30];
44 	char bat_model[30];
45 	char bat_type[30];
46 };
47 
48 enum {
49 	SLOT_STATUS,
50 	VOLTAGE,
51 	TIME_REMAINING,
52 	CURRENT,
53 	AVERAGE_CURRENT,
54 	AVERAGING_TIME_INTERVAL,
55 	CAPACITY_REMAINING,
56 	LAST_FULL_CHARGE_CAPACITY,
57 	DESIGN_CAPACITY,
58 	CRITICAL_CAPACITY,
59 	TEMPERATURE,
60 	MANUFACTURER,
61 	MODEL,
62 	TYPE,
63 };
64 
65 enum {
66 	AC,
67 	BAT,
68 };
69 
70 struct bat_response {
71 	u8 event_type;
72 	u8 length;
73 	u8 sub_type;
74 	u8 status;
75 	/* payload */
76 	union {
77 		char plc[30];
78 		u16 plu;
79 		s16 pls;
80 	};
81 };
82 
83 static struct power_supply nvec_bat_psy;
84 static struct power_supply nvec_psy;
85 
nvec_power_notifier(struct notifier_block * nb,unsigned long event_type,void * data)86 static int nvec_power_notifier(struct notifier_block *nb,
87 			       unsigned long event_type, void *data)
88 {
89 	struct nvec_power *power =
90 	    container_of(nb, struct nvec_power, notifier);
91 	struct bat_response *res = (struct bat_response *)data;
92 
93 	if (event_type != NVEC_SYS)
94 		return NOTIFY_DONE;
95 
96 	if (res->sub_type == 0) {
97 		if (power->on != res->plu) {
98 			power->on = res->plu;
99 			power_supply_changed(&nvec_psy);
100 		}
101 		return NOTIFY_STOP;
102 	}
103 	return NOTIFY_OK;
104 }
105 
106 static const int bat_init[] = {
107 	LAST_FULL_CHARGE_CAPACITY, DESIGN_CAPACITY, CRITICAL_CAPACITY,
108 	MANUFACTURER, MODEL, TYPE,
109 };
110 
get_bat_mfg_data(struct nvec_power * power)111 static void get_bat_mfg_data(struct nvec_power *power)
112 {
113 	int i;
114 	char buf[] = { '\x02', '\x00' };
115 
116 	for (i = 0; i < ARRAY_SIZE(bat_init); i++) {
117 		buf[1] = bat_init[i];
118 		nvec_write_async(power->nvec, buf, 2);
119 	}
120 }
121 
nvec_power_bat_notifier(struct notifier_block * nb,unsigned long event_type,void * data)122 static int nvec_power_bat_notifier(struct notifier_block *nb,
123 				   unsigned long event_type, void *data)
124 {
125 	struct nvec_power *power =
126 	    container_of(nb, struct nvec_power, notifier);
127 	struct bat_response *res = (struct bat_response *)data;
128 	int status_changed = 0;
129 
130 	if (event_type != NVEC_BAT)
131 		return NOTIFY_DONE;
132 
133 	switch (res->sub_type) {
134 	case SLOT_STATUS:
135 		if (res->plc[0] & 1) {
136 			if (power->bat_present == 0) {
137 				status_changed = 1;
138 				get_bat_mfg_data(power);
139 			}
140 
141 			power->bat_present = 1;
142 
143 			switch ((res->plc[0] >> 1) & 3) {
144 			case 0:
145 				power->bat_status =
146 				    POWER_SUPPLY_STATUS_NOT_CHARGING;
147 				break;
148 			case 1:
149 				power->bat_status =
150 				    POWER_SUPPLY_STATUS_CHARGING;
151 				break;
152 			case 2:
153 				power->bat_status =
154 				    POWER_SUPPLY_STATUS_DISCHARGING;
155 				break;
156 			default:
157 				power->bat_status = POWER_SUPPLY_STATUS_UNKNOWN;
158 			}
159 		} else {
160 			if (power->bat_present == 1)
161 				status_changed = 1;
162 
163 			power->bat_present = 0;
164 			power->bat_status = POWER_SUPPLY_STATUS_UNKNOWN;
165 		}
166 		power->bat_cap = res->plc[1];
167 		if (status_changed)
168 			power_supply_changed(&nvec_bat_psy);
169 		break;
170 	case VOLTAGE:
171 		power->bat_voltage_now = res->plu * 1000;
172 		break;
173 	case TIME_REMAINING:
174 		power->time_remain = res->plu * 3600;
175 		break;
176 	case CURRENT:
177 		power->bat_current_now = res->pls * 1000;
178 		break;
179 	case AVERAGE_CURRENT:
180 		power->bat_current_avg = res->pls * 1000;
181 		break;
182 	case CAPACITY_REMAINING:
183 		power->capacity_remain = res->plu * 1000;
184 		break;
185 	case LAST_FULL_CHARGE_CAPACITY:
186 		power->charge_last_full = res->plu * 1000;
187 		break;
188 	case DESIGN_CAPACITY:
189 		power->charge_full_design = res->plu * 1000;
190 		break;
191 	case CRITICAL_CAPACITY:
192 		power->critical_capacity = res->plu * 1000;
193 		break;
194 	case TEMPERATURE:
195 		power->bat_temperature = res->plu - 2732;
196 		break;
197 	case MANUFACTURER:
198 		memcpy(power->bat_manu, &res->plc, res->length - 2);
199 		power->bat_model[res->length - 2] = '\0';
200 		break;
201 	case MODEL:
202 		memcpy(power->bat_model, &res->plc, res->length - 2);
203 		power->bat_model[res->length - 2] = '\0';
204 		break;
205 	case TYPE:
206 		memcpy(power->bat_type, &res->plc, res->length - 2);
207 		power->bat_type[res->length - 2] = '\0';
208 		/* this differs a little from the spec
209 		   fill in more if you find some */
210 		if (!strncmp(power->bat_type, "Li", 30))
211 			power->bat_type_enum = POWER_SUPPLY_TECHNOLOGY_LION;
212 		else
213 			power->bat_type_enum = POWER_SUPPLY_TECHNOLOGY_UNKNOWN;
214 		break;
215 	default:
216 		return NOTIFY_STOP;
217 	}
218 
219 	return NOTIFY_STOP;
220 }
221 
nvec_power_get_property(struct power_supply * psy,enum power_supply_property psp,union power_supply_propval * val)222 static int nvec_power_get_property(struct power_supply *psy,
223 				   enum power_supply_property psp,
224 				   union power_supply_propval *val)
225 {
226 	struct nvec_power *power = dev_get_drvdata(psy->dev->parent);
227 	switch (psp) {
228 	case POWER_SUPPLY_PROP_ONLINE:
229 		val->intval = power->on;
230 		break;
231 	default:
232 		return -EINVAL;
233 	}
234 	return 0;
235 }
236 
nvec_battery_get_property(struct power_supply * psy,enum power_supply_property psp,union power_supply_propval * val)237 static int nvec_battery_get_property(struct power_supply *psy,
238 				     enum power_supply_property psp,
239 				     union power_supply_propval *val)
240 {
241 	struct nvec_power *power = dev_get_drvdata(psy->dev->parent);
242 
243 	switch (psp) {
244 	case POWER_SUPPLY_PROP_STATUS:
245 		val->intval = power->bat_status;
246 		break;
247 	case POWER_SUPPLY_PROP_CAPACITY:
248 		val->intval = power->bat_cap;
249 		break;
250 	case POWER_SUPPLY_PROP_PRESENT:
251 		val->intval = power->bat_present;
252 		break;
253 	case POWER_SUPPLY_PROP_VOLTAGE_NOW:
254 		val->intval = power->bat_voltage_now;
255 		break;
256 	case POWER_SUPPLY_PROP_CURRENT_NOW:
257 		val->intval = power->bat_current_now;
258 		break;
259 	case POWER_SUPPLY_PROP_CURRENT_AVG:
260 		val->intval = power->bat_current_avg;
261 		break;
262 	case POWER_SUPPLY_PROP_TIME_TO_EMPTY_NOW:
263 		val->intval = power->time_remain;
264 		break;
265 	case POWER_SUPPLY_PROP_CHARGE_FULL_DESIGN:
266 		val->intval = power->charge_full_design;
267 		break;
268 	case POWER_SUPPLY_PROP_CHARGE_FULL:
269 		val->intval = power->charge_last_full;
270 		break;
271 	case POWER_SUPPLY_PROP_CHARGE_EMPTY:
272 		val->intval = power->critical_capacity;
273 		break;
274 	case POWER_SUPPLY_PROP_CHARGE_NOW:
275 		val->intval = power->capacity_remain;
276 		break;
277 	case POWER_SUPPLY_PROP_TEMP:
278 		val->intval = power->bat_temperature;
279 		break;
280 	case POWER_SUPPLY_PROP_MANUFACTURER:
281 		val->strval = power->bat_manu;
282 		break;
283 	case POWER_SUPPLY_PROP_MODEL_NAME:
284 		val->strval = power->bat_model;
285 		break;
286 	case POWER_SUPPLY_PROP_TECHNOLOGY:
287 		val->intval = power->bat_type_enum;
288 		break;
289 	default:
290 		return -EINVAL;
291 	}
292 	return 0;
293 }
294 
295 static enum power_supply_property nvec_power_props[] = {
296 	POWER_SUPPLY_PROP_ONLINE,
297 };
298 
299 static enum power_supply_property nvec_battery_props[] = {
300 	POWER_SUPPLY_PROP_STATUS,
301 	POWER_SUPPLY_PROP_PRESENT,
302 	POWER_SUPPLY_PROP_CAPACITY,
303 	POWER_SUPPLY_PROP_VOLTAGE_NOW,
304 	POWER_SUPPLY_PROP_CURRENT_NOW,
305 #ifdef EC_FULL_DIAG
306 	POWER_SUPPLY_PROP_CURRENT_AVG,
307 	POWER_SUPPLY_PROP_TEMP,
308 	POWER_SUPPLY_PROP_TIME_TO_EMPTY_NOW,
309 #endif
310 	POWER_SUPPLY_PROP_CHARGE_FULL_DESIGN,
311 	POWER_SUPPLY_PROP_CHARGE_FULL,
312 	POWER_SUPPLY_PROP_CHARGE_EMPTY,
313 	POWER_SUPPLY_PROP_CHARGE_NOW,
314 	POWER_SUPPLY_PROP_MANUFACTURER,
315 	POWER_SUPPLY_PROP_MODEL_NAME,
316 	POWER_SUPPLY_PROP_TECHNOLOGY,
317 };
318 
319 static char *nvec_power_supplied_to[] = {
320 	"battery",
321 };
322 
323 static struct power_supply nvec_bat_psy = {
324 	.name = "battery",
325 	.type = POWER_SUPPLY_TYPE_BATTERY,
326 	.properties = nvec_battery_props,
327 	.num_properties = ARRAY_SIZE(nvec_battery_props),
328 	.get_property = nvec_battery_get_property,
329 };
330 
331 static struct power_supply nvec_psy = {
332 	.name = "ac",
333 	.type = POWER_SUPPLY_TYPE_MAINS,
334 	.supplied_to = nvec_power_supplied_to,
335 	.num_supplicants = ARRAY_SIZE(nvec_power_supplied_to),
336 	.properties = nvec_power_props,
337 	.num_properties = ARRAY_SIZE(nvec_power_props),
338 	.get_property = nvec_power_get_property,
339 };
340 
341 static int counter;
342 static int const bat_iter[] = {
343 	SLOT_STATUS, VOLTAGE, CURRENT, CAPACITY_REMAINING,
344 #ifdef EC_FULL_DIAG
345 	AVERAGE_CURRENT, TEMPERATURE, TIME_REMAINING,
346 #endif
347 };
348 
nvec_power_poll(struct work_struct * work)349 static void nvec_power_poll(struct work_struct *work)
350 {
351 	char buf[] = { '\x01', '\x00' };
352 	struct nvec_power *power = container_of(work, struct nvec_power,
353 						poller.work);
354 
355 	if (counter >= ARRAY_SIZE(bat_iter))
356 		counter = 0;
357 
358 /* AC status via sys req */
359 	nvec_write_async(power->nvec, buf, 2);
360 	msleep(100);
361 
362 /* select a battery request function via round robin
363    doing it all at once seems to overload the power supply */
364 	buf[0] = '\x02';	/* battery */
365 	buf[1] = bat_iter[counter++];
366 	nvec_write_async(power->nvec, buf, 2);
367 
368 	schedule_delayed_work(to_delayed_work(work), msecs_to_jiffies(5000));
369 };
370 
nvec_power_probe(struct platform_device * pdev)371 static int __devinit nvec_power_probe(struct platform_device *pdev)
372 {
373 	struct power_supply *psy;
374 	struct nvec_power *power =
375 	    kzalloc(sizeof(struct nvec_power), GFP_NOWAIT);
376 	struct nvec_chip *nvec = dev_get_drvdata(pdev->dev.parent);
377 
378 	dev_set_drvdata(&pdev->dev, power);
379 	power->nvec = nvec;
380 
381 	switch (pdev->id) {
382 	case AC:
383 		psy = &nvec_psy;
384 
385 		power->notifier.notifier_call = nvec_power_notifier;
386 
387 		INIT_DELAYED_WORK(&power->poller, nvec_power_poll);
388 		schedule_delayed_work(&power->poller, msecs_to_jiffies(5000));
389 		break;
390 	case BAT:
391 		psy = &nvec_bat_psy;
392 
393 		power->notifier.notifier_call = nvec_power_bat_notifier;
394 		break;
395 	default:
396 		kfree(power);
397 		return -ENODEV;
398 	}
399 
400 	nvec_register_notifier(nvec, &power->notifier, NVEC_SYS);
401 
402 	if (pdev->id == BAT)
403 		get_bat_mfg_data(power);
404 
405 	return power_supply_register(&pdev->dev, psy);
406 }
407 
408 static struct platform_driver nvec_power_driver = {
409 	.probe = nvec_power_probe,
410 	.driver = {
411 		   .name = "nvec-power",
412 		   .owner = THIS_MODULE,
413 		   }
414 };
415 
nvec_power_init(void)416 static int __init nvec_power_init(void)
417 {
418 	return platform_driver_register(&nvec_power_driver);
419 }
420 
421 module_init(nvec_power_init);
422 
423 MODULE_AUTHOR("Ilya Petrov <ilya.muromec@gmail.com>");
424 MODULE_LICENSE("GPL");
425 MODULE_DESCRIPTION("NVEC battery and AC driver");
426 MODULE_ALIAS("platform:nvec-power");
427