• Home
  • Line#
  • Scopes#
  • Navigate#
  • Raw
  • Download
1What:		/sys/bus/iio/devices/deviceX/inY-inZ_balance_switch_en
2KernelVersion:	3.0.0
3Contact:	linux-iio@vger.kernel.org
4Description:
5		Writing 1 enables the cell balance output switch corresponding
6		to input Y. Writing 0 disables it. If the inY-inZ_balance_timer
7		is set to a none zero value, the corresponding switch will
8		enable for the programmed amount of time, before it
9		automatically disables.
10
11What:		/sys/bus/iio/devices/deviceX/inY-inZ_balance_timer
12KernelVersion:	3.0.0
13Contact:	linux-iio@vger.kernel.org
14Description:
15		The inY-inZ_balance_timer file allows the user to program
16		individual times for each cell balance output. The AD7280A
17		allows the user to set the timer to a value from 0 minutes to
18		36.9 minutes. The resolution of the timer is 71.5 sec.
19		The value written is the on-time in milliseconds. When the
20		timer value is set 0, the timer is disabled. The cell balance
21		outputs are controlled only by inY-inZ_balance_switch_en.
22