• Home
  • Line#
  • Scopes#
  • Navigate#
  • Raw
  • Download
1=======================
2Energy Aware Scheduling
3=======================
4
51. Introduction
6---------------
7
8Energy Aware Scheduling (or EAS) gives the scheduler the ability to predict
9the impact of its decisions on the energy consumed by CPUs. EAS relies on an
10Energy Model (EM) of the CPUs to select an energy efficient CPU for each task,
11with a minimal impact on throughput. This document aims at providing an
12introduction on how EAS works, what are the main design decisions behind it, and
13details what is needed to get it to run.
14
15Before going any further, please note that at the time of writing::
16
17   /!\ EAS does not support platforms with symmetric CPU topologies /!\
18
19EAS operates only on heterogeneous CPU topologies (such as Arm big.LITTLE)
20because this is where the potential for saving energy through scheduling is
21the highest.
22
23The actual EM used by EAS is _not_ maintained by the scheduler, but by a
24dedicated framework. For details about this framework and what it provides,
25please refer to its documentation (see Documentation/power/energy-model.rst).
26
27
282. Background and Terminology
29-----------------------------
30
31To make it clear from the start:
32 - energy = [joule] (resource like a battery on powered devices)
33 - power = energy/time = [joule/second] = [watt]
34
35The goal of EAS is to minimize energy, while still getting the job done. That
36is, we want to maximize::
37
38	performance [inst/s]
39	--------------------
40	    power [W]
41
42which is equivalent to minimizing::
43
44	energy [J]
45	-----------
46	instruction
47
48while still getting 'good' performance. It is essentially an alternative
49optimization objective to the current performance-only objective for the
50scheduler. This alternative considers two objectives: energy-efficiency and
51performance.
52
53The idea behind introducing an EM is to allow the scheduler to evaluate the
54implications of its decisions rather than blindly applying energy-saving
55techniques that may have positive effects only on some platforms. At the same
56time, the EM must be as simple as possible to minimize the scheduler latency
57impact.
58
59In short, EAS changes the way CFS tasks are assigned to CPUs. When it is time
60for the scheduler to decide where a task should run (during wake-up), the EM
61is used to break the tie between several good CPU candidates and pick the one
62that is predicted to yield the best energy consumption without harming the
63system's throughput. The predictions made by EAS rely on specific elements of
64knowledge about the platform's topology, which include the 'capacity' of CPUs,
65and their respective energy costs.
66
67
683. Topology information
69-----------------------
70
71EAS (as well as the rest of the scheduler) uses the notion of 'capacity' to
72differentiate CPUs with different computing throughput. The 'capacity' of a CPU
73represents the amount of work it can absorb when running at its highest
74frequency compared to the most capable CPU of the system. Capacity values are
75normalized in a 1024 range, and are comparable with the utilization signals of
76tasks and CPUs computed by the Per-Entity Load Tracking (PELT) mechanism. Thanks
77to capacity and utilization values, EAS is able to estimate how big/busy a
78task/CPU is, and to take this into consideration when evaluating performance vs
79energy trade-offs. The capacity of CPUs is provided via arch-specific code
80through the arch_scale_cpu_capacity() callback.
81
82The rest of platform knowledge used by EAS is directly read from the Energy
83Model (EM) framework. The EM of a platform is composed of a power cost table
84per 'performance domain' in the system (see Documentation/power/energy-model.rst
85for futher details about performance domains).
86
87The scheduler manages references to the EM objects in the topology code when the
88scheduling domains are built, or re-built. For each root domain (rd), the
89scheduler maintains a singly linked list of all performance domains intersecting
90the current rd->span. Each node in the list contains a pointer to a struct
91em_perf_domain as provided by the EM framework.
92
93The lists are attached to the root domains in order to cope with exclusive
94cpuset configurations. Since the boundaries of exclusive cpusets do not
95necessarily match those of performance domains, the lists of different root
96domains can contain duplicate elements.
97
98Example 1.
99    Let us consider a platform with 12 CPUs, split in 3 performance domains
100    (pd0, pd4 and pd8), organized as follows::
101
102	          CPUs:   0 1 2 3 4 5 6 7 8 9 10 11
103	          PDs:   |--pd0--|--pd4--|---pd8---|
104	          RDs:   |----rd1----|-----rd2-----|
105
106    Now, consider that userspace decided to split the system with two
107    exclusive cpusets, hence creating two independent root domains, each
108    containing 6 CPUs. The two root domains are denoted rd1 and rd2 in the
109    above figure. Since pd4 intersects with both rd1 and rd2, it will be
110    present in the linked list '->pd' attached to each of them:
111
112       * rd1->pd: pd0 -> pd4
113       * rd2->pd: pd4 -> pd8
114
115    Please note that the scheduler will create two duplicate list nodes for
116    pd4 (one for each list). However, both just hold a pointer to the same
117    shared data structure of the EM framework.
118
119Since the access to these lists can happen concurrently with hotplug and other
120things, they are protected by RCU, like the rest of topology structures
121manipulated by the scheduler.
122
123EAS also maintains a static key (sched_energy_present) which is enabled when at
124least one root domain meets all conditions for EAS to start. Those conditions
125are summarized in Section 6.
126
127
1284. Energy-Aware task placement
129------------------------------
130
131EAS overrides the CFS task wake-up balancing code. It uses the EM of the
132platform and the PELT signals to choose an energy-efficient target CPU during
133wake-up balance. When EAS is enabled, select_task_rq_fair() calls
134find_energy_efficient_cpu() to do the placement decision. This function looks
135for the CPU with the highest spare capacity (CPU capacity - CPU utilization) in
136each performance domain since it is the one which will allow us to keep the
137frequency the lowest. Then, the function checks if placing the task there could
138save energy compared to leaving it on prev_cpu, i.e. the CPU where the task ran
139in its previous activation.
140
141find_energy_efficient_cpu() uses compute_energy() to estimate what will be the
142energy consumed by the system if the waking task was migrated. compute_energy()
143looks at the current utilization landscape of the CPUs and adjusts it to
144'simulate' the task migration. The EM framework provides the em_pd_energy() API
145which computes the expected energy consumption of each performance domain for
146the given utilization landscape.
147
148An example of energy-optimized task placement decision is detailed below.
149
150Example 2.
151    Let us consider a (fake) platform with 2 independent performance domains
152    composed of two CPUs each. CPU0 and CPU1 are little CPUs; CPU2 and CPU3
153    are big.
154
155    The scheduler must decide where to place a task P whose util_avg = 200
156    and prev_cpu = 0.
157
158    The current utilization landscape of the CPUs is depicted on the graph
159    below. CPUs 0-3 have a util_avg of 400, 100, 600 and 500 respectively
160    Each performance domain has three Operating Performance Points (OPPs).
161    The CPU capacity and power cost associated with each OPP is listed in
162    the Energy Model table. The util_avg of P is shown on the figures
163    below as 'PP'::
164
165     CPU util.
166      1024                 - - - - - - -              Energy Model
167                                               +-----------+-------------+
168                                               |  Little   |     Big     |
169       768                 =============       +-----+-----+------+------+
170                                               | Cap | Pwr | Cap  | Pwr  |
171                                               +-----+-----+------+------+
172       512  ===========    - ##- - - - -       | 170 | 50  | 512  | 400  |
173                             ##     ##         | 341 | 150 | 768  | 800  |
174       341  -PP - - - -      ##     ##         | 512 | 300 | 1024 | 1700 |
175             PP              ##     ##         +-----+-----+------+------+
176       170  -## - - - -      ##     ##
177             ##     ##       ##     ##
178           ------------    -------------
179            CPU0   CPU1     CPU2   CPU3
180
181      Current OPP: =====       Other OPP: - - -     util_avg (100 each): ##
182
183
184    find_energy_efficient_cpu() will first look for the CPUs with the
185    maximum spare capacity in the two performance domains. In this example,
186    CPU1 and CPU3. Then it will estimate the energy of the system if P was
187    placed on either of them, and check if that would save some energy
188    compared to leaving P on CPU0. EAS assumes that OPPs follow utilization
189    (which is coherent with the behaviour of the schedutil CPUFreq
190    governor, see Section 6. for more details on this topic).
191
192    **Case 1. P is migrated to CPU1**::
193
194      1024                 - - - - - - -
195
196                                            Energy calculation:
197       768                 =============     * CPU0: 200 / 341 * 150 = 88
198                                             * CPU1: 300 / 341 * 150 = 131
199                                             * CPU2: 600 / 768 * 800 = 625
200       512  - - - - - -    - ##- - - - -     * CPU3: 500 / 768 * 800 = 520
201                             ##     ##          => total_energy = 1364
202       341  ===========      ##     ##
203                    PP       ##     ##
204       170  -## - - PP-      ##     ##
205             ##     ##       ##     ##
206           ------------    -------------
207            CPU0   CPU1     CPU2   CPU3
208
209
210    **Case 2. P is migrated to CPU3**::
211
212      1024                 - - - - - - -
213
214                                            Energy calculation:
215       768                 =============     * CPU0: 200 / 341 * 150 = 88
216                                             * CPU1: 100 / 341 * 150 = 43
217                                    PP       * CPU2: 600 / 768 * 800 = 625
218       512  - - - - - -    - ##- - -PP -     * CPU3: 700 / 768 * 800 = 729
219                             ##     ##          => total_energy = 1485
220       341  ===========      ##     ##
221                             ##     ##
222       170  -## - - - -      ##     ##
223             ##     ##       ##     ##
224           ------------    -------------
225            CPU0   CPU1     CPU2   CPU3
226
227
228    **Case 3. P stays on prev_cpu / CPU 0**::
229
230      1024                 - - - - - - -
231
232                                            Energy calculation:
233       768                 =============     * CPU0: 400 / 512 * 300 = 234
234                                             * CPU1: 100 / 512 * 300 = 58
235                                             * CPU2: 600 / 768 * 800 = 625
236       512  ===========    - ##- - - - -     * CPU3: 500 / 768 * 800 = 520
237                             ##     ##          => total_energy = 1437
238       341  -PP - - - -      ##     ##
239             PP              ##     ##
240       170  -## - - - -      ##     ##
241             ##     ##       ##     ##
242           ------------    -------------
243            CPU0   CPU1     CPU2   CPU3
244
245
246    From these calculations, the Case 1 has the lowest total energy. So CPU 1
247    is be the best candidate from an energy-efficiency standpoint.
248
249Big CPUs are generally more power hungry than the little ones and are thus used
250mainly when a task doesn't fit the littles. However, little CPUs aren't always
251necessarily more energy-efficient than big CPUs. For some systems, the high OPPs
252of the little CPUs can be less energy-efficient than the lowest OPPs of the
253bigs, for example. So, if the little CPUs happen to have enough utilization at
254a specific point in time, a small task waking up at that moment could be better
255of executing on the big side in order to save energy, even though it would fit
256on the little side.
257
258And even in the case where all OPPs of the big CPUs are less energy-efficient
259than those of the little, using the big CPUs for a small task might still, under
260specific conditions, save energy. Indeed, placing a task on a little CPU can
261result in raising the OPP of the entire performance domain, and that will
262increase the cost of the tasks already running there. If the waking task is
263placed on a big CPU, its own execution cost might be higher than if it was
264running on a little, but it won't impact the other tasks of the little CPUs
265which will keep running at a lower OPP. So, when considering the total energy
266consumed by CPUs, the extra cost of running that one task on a big core can be
267smaller than the cost of raising the OPP on the little CPUs for all the other
268tasks.
269
270The examples above would be nearly impossible to get right in a generic way, and
271for all platforms, without knowing the cost of running at different OPPs on all
272CPUs of the system. Thanks to its EM-based design, EAS should cope with them
273correctly without too many troubles. However, in order to ensure a minimal
274impact on throughput for high-utilization scenarios, EAS also implements another
275mechanism called 'over-utilization'.
276
277
2785. Over-utilization
279-------------------
280
281From a general standpoint, the use-cases where EAS can help the most are those
282involving a light/medium CPU utilization. Whenever long CPU-bound tasks are
283being run, they will require all of the available CPU capacity, and there isn't
284much that can be done by the scheduler to save energy without severly harming
285throughput. In order to avoid hurting performance with EAS, CPUs are flagged as
286'over-utilized' as soon as they are used at more than 80% of their compute
287capacity. As long as no CPUs are over-utilized in a root domain, load balancing
288is disabled and EAS overridess the wake-up balancing code. EAS is likely to load
289the most energy efficient CPUs of the system more than the others if that can be
290done without harming throughput. So, the load-balancer is disabled to prevent
291it from breaking the energy-efficient task placement found by EAS. It is safe to
292do so when the system isn't overutilized since being below the 80% tipping point
293implies that:
294
295    a. there is some idle time on all CPUs, so the utilization signals used by
296       EAS are likely to accurately represent the 'size' of the various tasks
297       in the system;
298    b. all tasks should already be provided with enough CPU capacity,
299       regardless of their nice values;
300    c. since there is spare capacity all tasks must be blocking/sleeping
301       regularly and balancing at wake-up is sufficient.
302
303As soon as one CPU goes above the 80% tipping point, at least one of the three
304assumptions above becomes incorrect. In this scenario, the 'overutilized' flag
305is raised for the entire root domain, EAS is disabled, and the load-balancer is
306re-enabled. By doing so, the scheduler falls back onto load-based algorithms for
307wake-up and load balance under CPU-bound conditions. This provides a better
308respect of the nice values of tasks.
309
310Since the notion of overutilization largely relies on detecting whether or not
311there is some idle time in the system, the CPU capacity 'stolen' by higher
312(than CFS) scheduling classes (as well as IRQ) must be taken into account. As
313such, the detection of overutilization accounts for the capacity used not only
314by CFS tasks, but also by the other scheduling classes and IRQ.
315
316
3176. Dependencies and requirements for EAS
318----------------------------------------
319
320Energy Aware Scheduling depends on the CPUs of the system having specific
321hardware properties and on other features of the kernel being enabled. This
322section lists these dependencies and provides hints as to how they can be met.
323
324
3256.1 - Asymmetric CPU topology
326^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
327
328
329As mentioned in the introduction, EAS is only supported on platforms with
330asymmetric CPU topologies for now. This requirement is checked at run-time by
331looking for the presence of the SD_ASYM_CPUCAPACITY flag when the scheduling
332domains are built.
333
334See Documentation/scheduler/sched-capacity.rst for requirements to be met for this
335flag to be set in the sched_domain hierarchy.
336
337Please note that EAS is not fundamentally incompatible with SMP, but no
338significant savings on SMP platforms have been observed yet. This restriction
339could be amended in the future if proven otherwise.
340
341
3426.2 - Energy Model presence
343^^^^^^^^^^^^^^^^^^^^^^^^^^^
344
345EAS uses the EM of a platform to estimate the impact of scheduling decisions on
346energy. So, your platform must provide power cost tables to the EM framework in
347order to make EAS start. To do so, please refer to documentation of the
348independent EM framework in Documentation/power/energy-model.rst.
349
350Please also note that the scheduling domains need to be re-built after the
351EM has been registered in order to start EAS.
352
353
3546.3 - Energy Model complexity
355^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
356
357The task wake-up path is very latency-sensitive. When the EM of a platform is
358too complex (too many CPUs, too many performance domains, too many performance
359states, ...), the cost of using it in the wake-up path can become prohibitive.
360The energy-aware wake-up algorithm has a complexity of:
361
362	C = Nd * (Nc + Ns)
363
364with: Nd the number of performance domains; Nc the number of CPUs; and Ns the
365total number of OPPs (ex: for two perf. domains with 4 OPPs each, Ns = 8).
366
367A complexity check is performed at the root domain level, when scheduling
368domains are built. EAS will not start on a root domain if its C happens to be
369higher than the completely arbitrary EM_MAX_COMPLEXITY threshold (2048 at the
370time of writing).
371
372If you really want to use EAS but the complexity of your platform's Energy
373Model is too high to be used with a single root domain, you're left with only
374two possible options:
375
376    1. split your system into separate, smaller, root domains using exclusive
377       cpusets and enable EAS locally on each of them. This option has the
378       benefit to work out of the box but the drawback of preventing load
379       balance between root domains, which can result in an unbalanced system
380       overall;
381    2. submit patches to reduce the complexity of the EAS wake-up algorithm,
382       hence enabling it to cope with larger EMs in reasonable time.
383
384
3856.4 - Schedutil governor
386^^^^^^^^^^^^^^^^^^^^^^^^
387
388EAS tries to predict at which OPP will the CPUs be running in the close future
389in order to estimate their energy consumption. To do so, it is assumed that OPPs
390of CPUs follow their utilization.
391
392Although it is very difficult to provide hard guarantees regarding the accuracy
393of this assumption in practice (because the hardware might not do what it is
394told to do, for example), schedutil as opposed to other CPUFreq governors at
395least _requests_ frequencies calculated using the utilization signals.
396Consequently, the only sane governor to use together with EAS is schedutil,
397because it is the only one providing some degree of consistency between
398frequency requests and energy predictions.
399
400Using EAS with any other governor than schedutil is not recommended.
401
402
4036.5 Scale-invariant utilization signals
404^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
405
406In order to make accurate prediction across CPUs and for all performance
407states, EAS needs frequency-invariant and CPU-invariant PELT signals. These can
408be obtained using the architecture-defined arch_scale{cpu,freq}_capacity()
409callbacks.
410
411Using EAS on a platform that doesn't implement these two callbacks is not
412supported.
413
414
4156.6 Multithreading (SMT)
416^^^^^^^^^^^^^^^^^^^^^^^^
417
418EAS in its current form is SMT unaware and is not able to leverage
419multithreaded hardware to save energy. EAS considers threads as independent
420CPUs, which can actually be counter-productive for both performance and energy.
421
422EAS on SMT is not supported.
423